1_
48.25" (122.5cm)
to clear open door
freestand
washer
on noor
fleer{ine
washer mounted on
optional pedestal
floorline
30.5" (77.5cm)*
to front of closed door
water supply
connection
on rear of unit _
27.0"
(68.5cm)
0
drain hose
of uniP
51.25"
(130cm)
36.0"
(9t.5cm)
I
* To obtain these minimal depth dimensions, dryer must be vented straight back. Using a quick-turn 90° elbow (right or down on freestanding dryer) adds approximately 0.75 in. (2.0 cm) to
installation depth. Upward venting of exhaust on pedestaFmounted or freestanding dryer adds approximately 4 in. (!02 ram) to installation depth. Leftward venting on pedestal-mounted
or freestanding dryer adds approximately 3.75 in. (9.5 cm) to installation depth. Downward venting of exhaust on pedestal-mounted dryer adds approximately 2.25 in. (5.7 cm) to
installation depth. These dimensions are based on matching 7.0 cu. ft. dryer, tf matching dryer is 5.8 cu. ft. version with optional side venting knockouts, dimensions will vary.
_Hot and cold inlet hose length approximately 43 inches (!09cm)
2Power supply cord length approximately 60 inches (t52.5cm).
3Drain hose length approximately 52 inches (!32cm).
48.25"(122.5cm)
todear
open door
30.5" (77.5cm) _ __
to front of closed door
71.5"
(t82cm)
water supply
connection
on rear of unit _
gas supply
pipe on rear
of gas unit
37"
(94cm)
27.0
(68.5cm)
0
0
power cord
on rear of unit 2
electrical
supply on
rear of unit
hose
on rear
of unit 3
centerline
height for
rear vent
39"
(99cm)
To obtain these minimal depth dimensions dryer must be vented straight back. Using a quick-turn 90° elbow (right) adds approximately 0.75 in. (2 cm) to installation depth. Upward
vent ng of exhaust on stacked dryer adds approx mately 4 n. (102 ram) to nstallat on depth. Downward vent ng of exhaust on stacked dryer adds approx matety 2.25 n. (6.5 cm) to
installation depth. Leftward venting of exhaust on stacked dryer adds approximately 3.75 in. (9.5 cm) to installation depth. These dimensions are based on matching 7.0 cu. ft. dryer, tf
matching dryer is 5.8 cu. ft. version with optional side venting knockouts, dimensions wilt vary.
_Hot and cold inlet hose length approximately 43 inches (!09cm)
2Power supply cord length approximately 60 inches (!52.5cm).
3Drain hose length approximately 52 inches (132cm).