Haier 0010554405B Installation Manual
Haier 0010554405B Installation Manual

Haier 0010554405B Installation Manual

Haier room air conditioner installation manual

Advertisement

Installation Manual of Room Air Conditioner

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
Accessory parts
No.
Accessory parts
1
Remote controller
2
R-03 dry battery
3
Mounting plate
4
Drain hose
4X50
5
Steel nail, cement
6
4X25
Plastic cap
Screw
Screw
7
8
Drain-elbow
9
Cover
10
Cushion
11
Connecting cable
Change for
12
fresh air box
Change for
13
fresh air
tube(suit)
14
Outlet joint
15
Outlet joint
Note:1.Cooling only units don't have Drain-elbow
2.
is only for the models of 18,22.
14
3.The models ZF don't have fresh function
and accessory parts related with freshing.
No.0010554405B
Necessary Tools for Installation
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
Drawing for the installation of indoor and outdoor units
Number
of
articles
1
2
Optional parts for piping
1
Mark
Parts name
A
Non-adhesive tape
1
Adhesive tape
B
C
Saddle(L.S) with screws
6
Connecting electric cable
D
for indoor and outdoor
Drain hose
E
4
F
Heating insulating material
6
Piping hole cover
G
1
1
4
1
1
1
2
1
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
9.Nipper
10.Gas leakage detector or
11.Measuring tape
Arrangement of piping directions
Rear left
Rear
Left
right
Right
Below
The marks from
The distance between the indoor unit and the floor should
be more than 2m.
soap-and-water solution
Attention must be paid to
the rising up of drain hose
A
to
G
in the figure are the parts numbers.
12.Reamer
G
F
A
C
12
13
D
E

Advertisement

Table of Contents
loading

Summary of Contents for Haier 0010554405B

  • Page 1: Installation Manual Of Room Air Conditioner

    Note:1.Cooling only units don't have Drain-elbow is only for the models of 18,22. 3.The models ZF don't have fresh function and accessory parts related with freshing. No.0010554405B Read this manual before installation Explain sufficiently the operating means to the user according to this manual.
  • Page 2: Selection Of Installation Place

    HSU-09C03/VA(ZXF) HSU-12C03/VA(ZXF) HSU-09H03/VA(ZXF) HSU-12H03/VA(ZXF) Floor fixing dimensions of the outdoor unit (Unit:mm) Fixing of outdoor unit Selection of Installation Place Indoor Unit Place, robust not causing vibration, where the body can be supported sufficiently. Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed.
  • Page 3: Installation Of The Indoor Unit

    Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. 2.
  • Page 4 1. Insert the drain hose into the dent of heat insulation materials of indoor unit. 2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. 3. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Lid for right piping Lid for under piping...
  • Page 5 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). 2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V. 3.
  • Page 6: Installation Of Outdoor Unit

    6.Easily-demount cleaning of indoor unit 1.Top inlet can be taken down Open the inlet grille, press the claw of the clip on the unit,then take down the top inlet.(according to figure 1) 2.Vertical flap can be taken down Overturn the vertical flap, press the claw of the clip ,then take down vertical flap.(according to figure 2) 3.Horizontal louvers can be taken down After taking down vertical flap.Horizontal louvers are appeared,draw...
  • Page 7: Purging Method

    5.Installation instruction on the outdoor part of the fresh air device 1.Remove the four screws of fresh air box from the back cover. 2.Use six screws to fix fresh air box onto the designated position on the outdoor unit. 3.Remove two screws of the pipe junction of the fresh air box, then insert the flared departure of the change for fresh air tube into the pipe junction and then fix with the screws.
  • Page 8: Power Source Installation

    1.Power Source Installation The power source must be exclusively used for air conditioner. (Over I0A) In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. For installation in other places, use a circuit breaker as far as possible.

Table of Contents