SUPPORTS Active PFC POWER SUPPLIES This CyberPower UPS system supports High Efficiency power supplies with Active Power Factor Correction (Active PFC). Active PFC is used to improve the efficiency of power delivery. The current US Energy Star®...
CP1500EPFCLCD,). If the rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip. BASIC OPERATION DESCRIPTION 1. Power Switch Used as the master on/off switch for equipment connected to the battery power supplied outlets.
The unit has three battery powered/surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your equipment during a power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical devices into the “Battery and Surge Protected Outlets”.
Reduce Energy Cost with GreenPower UPS Technology CyberPower’s goal is not only to provide eco-friendly products but also to bring the best value for consumers. The advanced energy-saving design improves the operating efficiency and eliminates waste energy consumption. As a result, consumers will enjoy significant energy cost savings with the adoption of GreenPower UPS technology.
Energy-Saving: The UPS in energy-saving bypass mode. See “CyberPower GreenPower UPS Technology” section for more information. LOAD capacity / Sensitivity setup: This meter displays the approximate output load level (in 20% increments) of the UPS battery outlets.
Page 7
F01: Battery Mode or AC/Utility Power Mode Overload fault (Turn on the UPS again.) F02: Battery Output Short fault (Turn on the UPS again.) F03: Charger Fault (Contact CyberPower Systems for support.) F04: Internal Fault (Contact CyberPower Systems for support.) OVER LOAD: This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded.
TECHNICAL SPECIFICATIONS Model CP1300EPFCLCD CP1500EPFCLCD Capacity (VA) 1300VA/780W 1500VA/900W Input Frequency Range 47~63Hz (Auto Sensing) AVR Function Output On Battery Output 230Vac +/-10% Voltage On Battery Output 50/60Hz +/-1% Frequency Overload Protection On Utility: Circuit Breaker, On Battery: Internal Current Limiting...