NOTE: THESE INSTRUCTIONS SHOULD BE LEFT WITH
THE APPLIANCE AND THE USER TO RETAIN FOR
FUTURE REFERENCE.
Aga Gas Fired ranges are delivered unassembled.
Before installation can be made the site is inspected for
suitability by an Authorised Aga Distributor and corrected
where necessary to conform with local installation codes
or in the absence of local codes with:
In Canada:
The CAN/CGA-B149 installation codes.
In U.S.:
The National Fuel Gas Code ANSI Z223. 1-latest edition.
Assembly is undertaken on site by the same Aga
Distributor to ensure correct performance and safety.

BASE OR HEARTH

It is essential that the base or hearth on which the range
stands should be level and strong enough to support the
weight of the range.
Approximate weights:-
Models GC (Open Flue) and GC (Direct Vent)
- 408kg (900lb)
Models GE (Open Flue) and GC (Direct Vent)
- 585kg (1290lb)
Installation Instructions for Aga Gas Fired Range
Models:
GC Open Flue Range (2 Oven)
GC Direct Vent Range (2 Oven)
GE Open Flue Range (4 Oven)
GE Direct Vent Range (4 Oven)
For U.S. and Canadian Markets
1
The top face of the hearth must be of non-combustible
material for a minimum thickness of 12mm (1/2in) and
comply with current Building Regulations and National
Fire Laws.
OPEN FLUE RANGE -
MODELS GC AND GE
The wall behind the cooker draft hood and flue connector
must have a minimum air gap of 57mm (2 1/4"). Any
openings in the wall behind the range or in the floor under
the range must be sealed before appliance installation.
Ensure the draft hood is securely bolted to the support
spigot as shown in Fig. 2.
NOTE: THIS IS NORMALLY FITTED AND SECURED BY
THE FACTORY BEFORE DESPATCH.
The wall behind the range must be the outside wall for
DIRECT VENT RANGE-
MODELS GC AND GE
the venting of flue products. Wall thickness between
150mm (6 in) and 355mm (14 in) can be catered for at the
same time as site inspection.
Alternatively, special lengths can be offered to order up to
a maximum of 610mm (24 in) long.
Open Flue - Models GC and GE
04/01 EINS 33644

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GC and is the answer not in the manual?

Questions and answers

Summary of Contents for AGA GC

  • Page 1: Base Or Hearth

    The National Fuel Gas Code ANSI Z223. 1-latest edition. THE FACTORY BEFORE DESPATCH. The wall behind the range must be the outside wall for Assembly is undertaken on site by the same Aga DIRECT VENT RANGE- Distributor to ensure correct performance and safety.
  • Page 2: Vent Connection

    Termination at the roofs eaves is unacceptable. as recommended in ANSI/NFPA 211 and according to The Aga Distributor or Local Gas Company should be manufacturers instructions. Chimneys and vents shall advised where any doubt arises as to the suitability of terminate above roof level and in accordance with the the flue.
  • Page 3: Wall Tiling

    The following notes are intended to give general guidance. 355mm (14in) overall thickness. 1. The range must be installed so that the flue terminal is For special lengths up to 610mm (24in), consult your local Aga exposed to the external air and terminal clearances comply Distributor.
  • Page 4: Location Of Name Plate

    The model and serial numbers for this appliance are found on the name plate. These numbers must be used when requesting advice from your Aga Distributor. The name plate is located on the inside face of the outer burner door. The maximum gas inlet pressure at the appliance must not exceed 12 inches w.g.
  • Page 5: Initial Lighting Of Range

    INITIAL LIGHTING OF RANGE anti-clockwise to its low fire position where upon the main In a cold range, difficulty may be experienced in maintaining burner will automatically light. Leave in the low fire position the main burner alight on initial light-up only. Should this for at least 30 minutes.
  • Page 6: Technical Specification

    NOTE: DO NOT ATTEMPT TO SERVICE THE RANGE TECHNICAL SPECIFICATION YOURSELF. CONTACT YOUR LOCAL AGA DISTRIBUTOR STATING THE MODEL AND SERIAL NUMBER TOGETHER Models GC and GE - Open Vent/GC and GE - Direct Vent WITH YOUR NAME AND ADDRESS Gas Type Natural Gas L.P.G.
  • Page 8: Yearly Service

    Arrange with the householder that the range has been turned OFF the night before to ensure it is cold upon arrival. 7. Refit combustion chamber baffle. 8. DIRECT VENT MODEL ONLY - GC AND GE. YEARLY SERVICE Using a wire brush, lightly remove the old sealing cement...

Table of Contents