Thermostat

Advertisement

Special Features:
Auto Fan
Stage Select (Two air conditioners/
heat pumps or models equipped with
two compressors)
Programs 1 & 2
Auxiliary Heat (heat pump models
only)
Load Shed
Automatic Generator Start (optional)
See Operating Instructions Manual
for more information on special fea-
ture.
LCD Error Code
When the system determines that one of
the faults listed below has occurred an
error code will be displayed in the LCD
for the zone in which the error occurred.
During normal operation, a blinking zone
number indicates a fault has occurred.
The error code is displayed in place of the
temperature set-point.
Error Code:
E1 Loss of communication between the
CCC 2 thermostat and all system
power module boards. System will
shut down.
E1 Loss of communication between the
CCC 2 thermostat and an individual
system power module board. The
LED will display error code E1 and
the zone number that lost communi-
cation. Any additional zones that lose
communication will blink in addition to
the current zone.
E2 Open circuit or out-of-range Indoor
Temperature Sensor. All heat, cool,
and dehumidify operation will be
locked out. Manual fan operation can
continue.
In the unlikely event you experience a system failure, refer to the "SERVICE" section of the Operating
Instructions furnished with your unit.
E3 Shorted Indoor Temperature Sensor.
All heat, cool, and dehumidify opera-
tion will be locked out. Manual fan op-
eration can continue.
E4 Open circuit or out of range Outdoor
Temperature Sensor (Select Models).
Heat pump and dehumidifi cation op-
eration will be locked out. Air condi-
tioner, furnace, heat strip, and fan op-
eration can continue to operate.
E5 Open circuit or out of range Freeze
Sensor (Select Models). Air condition-
er and dehumidifi cation operation will
be locked out. Heat pump, furnace,
heat strip, and fan operation can con-
tinue to operate but displays the last
temperature set-point.
E6 Open circuit Humidity Sensor (Select
Models). Air conditioner and dehu-
midifi cation operation will be locked
out. Heat pump, furnace, heat strip,
and fan can continue to operate.
E7 Loss of 120 VAC power to all power
module boards on the system. The
system will shut down.
E8 Invalid zone confi guration. The heat
pump and heat strip DIP switches
are both set to the ON position in one
zone. Heat pump, heat strip, air con-
ditioner, and
dehumidify operation
will be locked out in the affected zone.
E9 Invalid zone confi guration. The dehu-
midifi er DIP switch and either the heat
pump or heat strip DIP switches are
set to the ON position in one zone.
Heat pump, heat strip, air condition-
er, and dehumidify operation will be
locked out in the affected zone.
Comfort Control Center 2 Thermostat
User's Guide
Dometic Comfort Control Center 2 Thermostat Quick Start-Up
The basic steps for operating your Air Conditioner, Heat Pump or Dehumidifi er (herein
after referred to as the "unit"), are described in this User's Guide. For more detailed
information on modes of operation and special features refer to the Operating Instruc-
tions Manual.
Quick reference to control buttons
Press to select zone
Press to select
On and OFF
Press to select fan
speed
Press to set
clock
Press to
Press to select
select mode
program 1 or 2
USA
SERVICE OFFICE
Dometic, LLC
2320 Industrial Parkway
Brantford, ON N3T 5L8
Elkhart, IN 46516
574-294-2511
Press to increase temperature
or humidity set-point
Press to display
inside temperature
Press to select
temperature format
Press to display
Press to decrease
relative humidity set-
temperature or
point (Select Models)
humidity set-point
CANADA
For Service Center
Dometic, LLC
Assistance Call:
46 Zatonski, Unit 3
800-544-4881
CANADA
Form No. 3314150.016 10/11
519-720-9578
(Replaces 3314150.000)
3314150.016
(French 3314170.014)
©2011 Dometic, LLC
LaGrange, IN 46761
REVISION

Advertisement

loading
Need help?

Need help?

Do you have a question about the Comfort Control Center 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dometic Comfort Control Center 2

  • Page 1 Heat pump, furnace, Dometic Comfort Control Center 2 Thermostat Quick Start-Up heat strip, and fan operation can con- The basic steps for operating your Air Conditioner, Heat Pump or Dehumidifi er (herein...
  • Page 2: Operation

    RV. The Dometic CCC 2 thermostat can control up to four units (zones). 7. Press and hold the INSIDE TEMP...