TOMAHAWK TW-9010 CONTENTS USER MANUAL System main features Remote control trinkets LCD features Arming mode Arming with siren disabled Automatic arming and re-arming Immobilizer features Disarming Opening/closing doors with engine working Two-step door opening/channel 3 Remote engine start-up Remote engine cut-off...
TOMAHAWK TW-9010 USER MANUAL 1. System Main Features 5-button 2-side programmable trinket with LCD LCD backlight Vibration mode Anti-scanner Anti-grabber Programmable trinkets (up to 4 items) Visual and sound confirmation of functions performed Arming with siren disabled Secured remote engine start-up/cut-off...
TOMAHAWK TW-9010 - hand-brake disengage indication - started engine indication - battery level indication - timer switch-on indication - alarm-clock switch-on indication - clock - temperature measurement units (C or F) 4. Arming Mode To arm a car, I is necessary to press button 1 time.
TOMAHAWK TW-9010 6. Auto Arming and Re-arming If the auto arming function is enabled, then: with ignition OFF, after all doors are closed the system will alert with 1 long “CHIRP” and will switch security mode ON 10 sec later (see Programming Table).
These functions require additional connection while installation. 11. Turbo Timer Tomahawk TW-9010 provides a turbo function for vehicles with turbo engines. If this function is enabled, the engine keeps on running after ignition OFF for 1, 3 or 6 min (see Programming Table).
14. Warming-up Engine to Specified Temperature Tomahawk provides for an auxiliary temperature sensor for installation under the hood (see Diagram No.10). If this sensor is installed, engine start and warm-up is performed by this sensor’s data, otherwise by the cabin temperature sensor data.
TOMAHAWK TW-9010 To disable this function, press buttons . Parking lights will flash 2 times and siren will sound 2 “CHIRPS” to confirm disabling the function. LCD will hide icon and a melody will play. Note: Automatic engine warming-up to specified temperature should be made six times per two hours as maximum.
TOMAHAWK TW-9010 17. Remote Boot Opening To remotely open the boot, press and hold button . Parking lights will flash 3 times to confirm the boot opening. LCD will display icon ATTENTION! This function requires auxiliary connection while installation 18. 2-nd Auxiliary Channel To enable this function, press and hold button .
TOMAHAWK TW-9010 On triggering the shock sensor main zone (strong shock), the system will enable alarm mode for 25 sec. LCD will display icon and an alarm signal will sound. On triggering any other zone, the system will enable alarm mode for 30 sec. LCD will display an icon corresponding to the triggered zone (see page 3) and an alarm signal will sound.
To enable this function, press call button located on antenna-transmitter. LCD will display icon , and a melody will play. 26. “Override” Button Functions Some of TOMAHAWK TW-9010 functions can be enabled without control trinkets. To enter this mode, do the following: 1. Switch ignition OFF 2.
TOMAHAWK TW-9010 1 “CHIRP” and flash – function enabled 2 “CHIRPS” and flashes – function disabled 7. Switch ignition OFF. NOTE: If the daily auto start function is enabled, the engine will start up immediately after ignition is switched OFF. Use your remote control trinket to stop the engine.
If all the steps are performed correctly, the system will automatically stop the engine, if not – capability of remote start-up will be disabled. 29. Programming Auxiliary Trinkets TOMAHAWK TW-9010 provides for recording up to 4 remote control trinkets in its memory. To record, perform the following: 1. Switch ignition ON (engine should not be started) 2.
TOMAHAWK TW-9010 6. The system will automatically exit the trinket programming mode, if it does not receive signals from the trinket within 6 sec. ATTENTION! All un-programmed trinkets will be erased from the memory. 30. LED Indicator Operation Modes The system displays its status using LED indicator when car ignition is switched OFF.
TOMAHAWK TW-9010 32. Programming Mode To enter the programming mode, perform the following: 1. Switch ignition ON (engine should not be started) 2. Press button “Override” 6 times 3. Switch ignition OFF (6 siren “CHIRPS” will confirm entry in programming mode) Use button “Override”...
TOMAHAWK TW-9010 33. Programming Trinket-pager Functions Buttons used Functions performed Notes Backlight switch On Disabled automatically after 5 sec Power saving mode switch ON Trinket-pager receiver switched OFF automatically 2 min after disarming Sound/Vibration mode toggle Clock, alarm-clock and timer setting mode...
TOMAHAWK TW-9010 34. Programming Table Number of “Override” Confirma- Description of function presses tion CHIRPS CHIRPS CHIRPS CHIRP 1 short “CHIRP” Time to stop engine after remote start (min) 1 time 2 times 2 short “ Specified engine temperature for automatic warm-up ( CHIRPS”...
TOMAHAWK TW-9010 35. Description of Programmable Functions 1. Time allotted for engine running after remote start-up: 5/10/15/20 min. 2. Engine temperature when automatic warm-up is switched ON (if the function is enabled): -5 /-20 3. Time for starter operation when remote start-up function is enabled: 800/1200/1800/3000 ms.
Page 22
TOMAHAWK TW-9010 5. Enabling impulse length for 2nd auxiliary channel: 0.8/10/30/constant. 6. Siren impulse (klaxon) duration: 100/10/15/20 msec. 7. Wire IGN 2 ON/OFF (see wiring diagram) and door auto closing at remote start-up: Version 1 – IGN 2 ON, locks do not close automatically at remote start-up;...
Page 23
TOMAHAWK TW-9010 Version 2 – Doors are automatically locked 10 sec after ignition ON and open immediately after ignition OFF. Version 3 – Doors are automatically locked 30 sec after ignition ON and open immediately after ignition OFF. 12. Auto arming.
INSTRUCTIONS FOR INSTALLATION 1. Basic Installation Principles TOMAHAWK TW-9010 vehicle alarm system has a classic connection arrangement. First of all, before installation disable vehicle power system (disconnect “–“ battery terminal). To choose places for alarm system units, follow the principles as below:...
TOMAHAWK TW-9010 3. Wire Connections 6 PIN Remote Start-up Power Socket 1. Black and yellow wire – starter switch-on wire (+12V). This is an output signal +12V to starting relay. It is connected to ignition lock wire where +12V appears in the “Starter” key position. This signal is for engine start-up.
Page 26
TOMAHAWK TW-9010 6 PIN Remote Start-up Power Socket 1. Blue wire – central contact for central lock opening relay 2. Blue and grey wire – normally open contact for central lock opening relay 3. Blue and black wire – normally closed contact for central lock opening relay 4.
Page 27
TOMAHAWK TW-9010 5. Yellow and red wire – 2nd auxiliary channel wire (-300mA). 6. Grey and black wire – input for tachometer wire or oil pressure sensor. Connect to tachometer signal wire or oil pressure sensor wire (programmable). 7. Blue and red wire – “+” input for door sensor.
5 PIN combined antenna socket Socket for combined antenna. 4. Selection of Automatic or Manual Transmission Selection of automatic or manual transmission in TOMAHAWK TW-9010 is done using jumper 1 (see wiring diagram). Jumper closed – automatic transmission Jumper open – manual transmission...
Please note that impulse duration for central lock control is a programmable function. 6. Setting Shock Sensor etting is the last installation stage of TOMAHAWK TW-9010 alarm system. Set shock sensor sensitivity to minimum. Gradually increase sensitivity and knock the car body with your palm to check triggering threshold.
Page 34
TOMAHAWK TW-9010 Connection of auxiliary electric drive Control time 0.8 sec Diagram 4 Central lock positive control Control time 0.8 sec Diagram 5...
Page 35
TOMAHAWK TW-9010 Central lock negative control Control time 0.8 sec Diagram 6 Pneumatic central lock (Audi, Mercedes) Control time 3.6 sec Diagram 7...
TOMAHAWK TW-9010 Engineering data Rated voltage +12V Current consumption 15mA Allowable current: 6 PIN remote start-up power socket In power supply circuit thick red wire (limited with fuse) In power supply circuit thin red wire (limited with fuse) IGN 1, “+”...
Page 39
TOMAHAWK TW-9010 18 PIN main socket Blocking relay contacts Blocking relay service output, “-“ 300mA (black and yellow wire) Siren power output, “+“ (grey wire) Auxiliary channel 1 output, “-“ 300mA (yellow and black wire) Auxiliary channel 2 output, “-“...
Page 40
TOMAHAWK TW-9010 Auxiliary channel 2 output, “-“ 0.8 sec (programmable) 10 sec (yellow and red wire) 30 sec Permanently Auxiliary channel 3 output, “-“ 0.8 sec (yellow and blue wire) Impulse duration for central lock control 0.8 sec (programmable) 3.6 sec...
Need help?
Do you have a question about the TW-9010 and is the answer not in the manual?