Brush Removal And Replacement - Vax V027 User Manual

Parts checklist
Table of Contents

Advertisement

V027(Y) User Guide
5/10/06
11:47 am
4
32
1. Loop the belt around the rear shaft.
2. Loop the top of the belt above the small
pulley and the bottom of the belt around the
lower small pulley.
3. Feed the entire belt over the first large
pulley.
4. Loop the belt around the front large pulley
and rotate the front brushbar forward until
the belt is in place.
Note: Make sure the entire belt stays on top of
the first large pulley by lightly placing a finder
on top to guide it.
2
33
Tilt cleaner off the carpet. Grasp
the brush bar and pull the right side
of its chamber.
Tilt the brushbar down to the
ground and remove the silver cap.
Slide the worn brushbar out of the
cleaner.
Page 16
Return the nozzle cover to the
original position.
Secure by replacing the two (2)
screws.
To install a new brushbar. Feed the
brushbar through the opening until
the screw plate and screw hole are
lined up (as above).
Note: The black cap behind the
silver screw plate will be through the
hole.
Brush removal and
replacement
5
Remove the screw that holds the
brushbar in place.
3
Replace the silver cap to right side
of the brushbar. Lift the brushbar up
and align with the brushbar
chamber. Push the screw plate
towards the screw hole until the
flush and replace the screw.
1
4

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V027 and is the answer not in the manual?

Questions and answers

Fiona
March 25, 2025

Hi. I’m using my V-027 vax fans it’s just soaking the rug and doesn’t seem to **** up the water from the rug

User image 67e2c072bde05
2 comments:
Mr. Anderson
March 25, 2025

Your Vax V027 may be soaking the rug instead of drying it due to one or more of the following reasons:

1. Overuse of Solution – Ensure you are not over-wetting carpets by using too much solution or holding the trigger for too long.
2. Float Activation – If the dirty water tank is full, the float shuts off suction. Empty the dirty water tank and allow the float to settle.
3. Nozzle Seal Issue – If the cleaner is tipped or the nozzle loses contact with the carpet, suction may be interrupted. Keep the nozzle flat against the carpet.
4. Soap Switch Issue – The soap switch should not be turned on without solution in the tank. Ensure proper priming before use.

Check these factors and make necessary adjustments to improve drying performance.

This answer is automatically generated

Fiona Thompson
March 25, 2025

@Mr. Anderson thank you so much. I will try this.