Operator Setup Menu Tree Guide; Pump Start Time (For Autoset); Intelli Address - Pentair ULTRATEMP Installation And User Manual

Hide thumbs Also See for ULTRATEMP:
Table of Contents

Advertisement

OPERATOR
Operator Set Up Menu Tree Guide
SETUP MENU TREE
(Press UP and DOWN Arrows Simultaneously)
LANGUAGE - IDIOMA
ENGLISH / ESPANOL
SOFTWARE VERSION
PUMP START TIME
TIME = 1 - 4 HRS
INTELL ADDRESS
ADDRESS = 1 - 16
TEMPERATURE SCALE
FAHRENHEIT / CELSIUS
WATER TEMP OFFSET
OFFSET = -2 TO +2
ENABLE / DISABLE
WP HP LP PL SP
1
FAN COMP PMP REV
1
**
PRESS POOL/SPA TO
**THE NUMBER ONE (1) IS DISPLAYED WHEN THE ASSOCIATED
INPUT/OUTPUT IS ON AND ZERO (0) IS DISPLAYED WHEN THE
EXIT SETUP
ASSOCIATED INPUT/OUTPUT IS OFF.
**
INPUT STATUS
**
WP = WATER PUMP SWITCH
HP = HIGH REFRIGERANT PRESSURE SWITCH
LP - LOW REFRIGERANT PRESSURE SWITCH
PL - POOL REMOTE
SP - SPA REMOTE
OUTPUT STATUS
FAN - FAN
COMP - COMPRESSOR
PMP - FILTER PUMP
REV - REVERSING VALVE
REV. ____
DEFROST
**
**
1
1
0
0
***
**
1
1
0
***
The number one (1) is
displayed when the
associated input/output is
ON and zero (0) is displayed
when input/output is OFF.
Navigating the Operator Set Up Screens
Press the Up and Down arrows simultaneously. If no
activity is detected after 15 seconds, the display will
return to the main screen.
1. Language Selection
Displays the language selected. Select either English
or Spanish using the UP and DOWN arrows.
2. Software Revision
Displays the software revision level loaded on the
control board.
3. Pump Start Time
This displays the period at which the heat pump
will close the AutoSet contactor to start the filter
pump. Adjustable from 1 to 4 hours using the UP
and DOWN arrows.
4. Intell Address
IntelliTouch
which must match the address used in the
IntelliTouch
being communicated with. Adjustable from 1 to 16
using the UP and DOWN arrows.
5. Temperature Scale
Determines if the water temperature actual reading
and set point is displayed in degrees Fahrenheit or
Celsius. Adjusted between Fahrenheit and Celsius
using the UP and DOWN arrows.
6. Temp Offset
Adjusts the measured water temperature up or
down to allow the operator to match the heat pump
measured temperature to a remote temperature
monitoring device. The offset can be varied from -2
to +2 using the UP and DOWN arrows.
**THE NUMBER ONE (1) IS DISPLAYED WHEN THE ASSOCIATED
7. Defrost Screen
INPUT/OUTPUT IS ON AND ZERO (0) IS DISPLAYED WHEN THE
Allows to Enable/Disable defrost cycle.
ASSOCIATED INPUT/OUTPUT IS OFF.
8. Input Screen
INPUT STATUS
The Input screen is a diagnostic display which
WP = WATER PUMP SWITCH
shows the status of the input sensors. The number
HP = HIGH REFRIGERANT PRESSURE SWITCH
1 is displayed when the associated input is on and
LP - LOW REFRIGERANT PRESSURE SWITCH
zero is displayed when the associated input is off.
PL - POOL REMOTE
SP - SPA REMOTE
9. Output Screen
The Output screen is a diagnostic display which
OUTPUT STATUS
shows the status of the Output devices. The number
FAN - FAN
1 is displayed when the associated output is on and
COMP - COMPRESSOR
zero is displayed when the associated output is off.
PMP - FILTER PUMP
REV - REVERSING VALVE
10. Exit Set Up
Pressing the POOL/SPA button while this screen is
displayed returns the display to the Pool or Spa Run
Screen as appropriate.
ULTRATEMP
®
RS-485 Communications Address
or EasyTouch
automation controller
®
®
Heat Pump Installation and User's Guide
®
17

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ULTRATEMP and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF