Asxc, dsxc, and gsxc condensing units,
aszc, dszc and gszc split system heat pumps with r-410a refrigerant blowers, coils, & accessories (109 pages)
Summary of Contents for Goodman GSZ/VSZ 13 SEER
Page 1
® GSZ/VSZ 13 SEER Split System Heat Pumps • Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information.
S: Goodman Deluxe V: Value PRODUCT TYPE: C: Condenser R-22 X: Condenser R-410A H: Heat Pump R-22 Z: Heat Pump R-410A HIGH VOLTAGE! WARNING WARNING Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death.
Page 3
PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. GSZ130181A* GSZ130241A* GSZ130301A* GSZ130361A* GSZ130421A* GSZ130481A* GSZ130601A* GSZ130241B* GSZ130361B* GSZ130363A* GSZ130483A* GSZ130484A* GSZ130603A* GSZ130604A* * Indicates minor revision &...
PRODUCT DESIGN GSZ/VSZ13 models are available in 1 1/2 through 5 ton sizes and use R-410A refrigerant. They are designed for 208/230 volt single phase applications. Select GSZ13 models are available in 208/230 and 460 volt 3-phase applications. These models use R-410A refrigerant. The condenser air is pulled through the condenser coil by a direct drive propeller fan.
PRODUCT DESIGN G/VSZ130181A* G/VSZ130241A* G/VSZ130241B* G/VSZ130301A* G/VSZ130361A* GSZ130363A* G/VSZ130361B* G/VSZ130421A* G/VSZ130481A* GSZ130483A* GSZ130484A* G/VSZ130601A* GZX130603A* GSZ130604A* Product Dimensions Model Dimensions - W x D x H 26 x 26 x 32¼ 26 x 26 x 32¼ 26 x 26 x 32½ 26 x 26 x 32¼...
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will occur in low and high side pressures and power. A properly operating unit should be within plus or minus 2 degrees of the subcooling value shown in the Heat Pump Specifications.
WIRING DIAGRAMS G/VSZ130[18-60]1[A/B]* ONLY CONTACTOR POLE DOUBLE ALTERNATE Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
Page 52
GSZ130181AC, GSZ130241BB, GSZ130301AD, GSZ130361BB WIRING DIAGRAMS GSZ130421AC, GSZ130481AC, GSZ130601AC VSZ130181AB, VSZ130241BB, VSZ130301AC, VSZ130361BB VSZ130421AB, VSZ130481AB, VSZ130601AB ONLY CONTACTOR POLE DOUBLE ALTERNATE Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
Page 53
WIRING DIAGRAMS LVDR HVDR Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GSZ130181AD, GSZ130241[B*/C*], GSZ130301A[E/F], GSZ130361BB VSZ130181A[C/D], VSZ130241B[B/C], VSZ130301A[D/E], VSZ130361B[B/C], VSZ130421A[C/D], VSZ130481A[C/D], VSZ130601AC ONLY CONTACTOR POLE DOUBLE ALTERNAT 0-RV C-RV...
Page 54
WIRING DIAGRAMS GSZ130[36-60][3,4]A* Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
Page 55
WIRING DIAGRAMS GSZ130[36-60][3,4]A* Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
Need help?
Do you have a question about the GSZ/VSZ 13 SEER and is the answer not in the manual?
Questions and answers