Note: There is no feedback protocol between host
computer and receiver no matter what which
interface equipped. The radio link between the
scanner and the receiver can work well as long as
stable power continuously supply for both of them.
Most computers provide +5V DC power from
keyboard port or USB port even they are at power
off state. So it might be a risk to loss the scanned
data when operator works in the field while host
computer acts abnormally such as hang-up, power
off, etc. This mode provides the last chance to trace
back the data.
Barcode attachment:
To read the barcode to transmit
data in the scanner's memory to PC.
-10-
7. Scanner programming:
The BT series can be configured via the Windows base
programming utility to meet special application needs
such as decoding options, code ID settings, etc.
Step 1. Run the bundled CD disk :\utilities\BTScanner.
Step 2. If the receiver is keyboard wedge interface, please
install KBIDrv (interface driver) and follow by
BT utility.
or
Step 2. If receiver is RS-232 or USB interface, then,
install BTScanner utility only.
Step 3. After step 2, please follow the dialog boxes of the
utility to do the necessary parameters
programming to meet your application needs and
transmits it.
Step 4. After step 3, the programmed values are stored at
the receiver. So, it is a compulsory step to push
the scanner trigger to transmit the programmed
values from receiver to scanner to complete the
scanner programming procedure under Bluetooth
radio link is built.
-11-
Need help?
Do you have a question about the BT series and is the answer not in the manual?
Questions and answers