OWNER'S MANUAL
PPU 15 Personal Power Unit
This pump complies with NFPA-1936, standard on powered rescue tool systems, 1999 edition.
918.269.011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PPU 15 and is the answer not in the manual?

Questions and answers

Summary of Contents for Holmatro PPU 15

  • Page 1 OWNER’S MANUAL PPU 15 Personal Power Unit This pump complies with NFPA-1936, standard on powered rescue tool systems, 1999 edition. 918.269.011...
  • Page 2 Holmatro reserves the right to change the contents of this manual at any time without prior notice. Holmatro also reserves the right to change any part or component of any machine referenced in this manual at any time without prior notice.
  • Page 3: Safety Instructions

    Use only original Holmatro accessories and parts. Observe the maintenance instructions. Only trained service technicians certified by Holmatro are allowed to repair this equipment. Replace safety symbols/pictograms and/or information labels if illegible, damaged or removed. Always place the pump on a stable firm base which is free of protrusions or loose matter (gravel, dust) Use the pump at a minimum distance of 3 feet (1 metre) from buildings/structures.
  • Page 4: Product Identification

    Description Product identification A. Hydraulic oil fill cap H. Choke lever B. Hydraulic oil level indicator Engine oil fill port C. Directional valve K. Engine oil drain pipe D. Valve block w/ couplings L. Fuel shutoff valve E. Hydraulic oil drain M.
  • Page 5: Operation

    Check whether the guarantee registration card has been supplied and filled in. This must be sent back to Holmatro to register your warranty. When you receive the pump it must first be made ready for operation. Perform the following actions: Remove the red shipping cap from the hydraulic tank and replace it with the orange breather cap.
  • Page 6 5.2.2 Coupling: The unit is equipped with different quick-action couplings, i.e. "male" and "female". Caution: Never connect or disconnect the quick-action coupling when the pump is in operation. Set the pump relief valve to its "neutral" position before coupling or uncoupling hoses and/or tools. To couple the hoses using the flat face coupler: 1.
  • Page 7: Pressure Relief Device

    5.2.3 Pressure relief device A pressure relief device is provided for relieving pressure in the hydraulic hose. The pressure relief device is only used to relieve pressure in hoses caused by elevated temperatures (i.e. if the hoses are left lying in the hot sun). Follow the operation instructions below for proper use of the relief device and observe all warnings...
  • Page 8: Shutting Down

    5.2.4 Starting: Switch the directional valve to its “Neutral –0” position. Switch the choke lever to its “CHOKE” position. Turn fuel shutoff valve to the “OPEN” position. Pull the cord until resistance is felt, let the cord be retracted and then pull fast. Repeat this if the engine does not start the first time.
  • Page 9: Cleaning And Storage

    The pump can be shut down after completion of the work. Close the tool(s) being operated with the pump. (Partially re-open the tool to relieve any pressure) Check that the pump relief valve is in its "neutral" position. (before uncoupling hoses). Press the “ENGINE STOP”...
  • Page 10 Hoses The hydraulic hoses belonging to the hydraulic system need attention. Observe the following points: Do not use hoses without proper anti-kink devices and prevent kinking behind the attachment. Prevent kinking of the hoses and never bend the hoses beyond their minimum bending radius - 89 mm (3 ½”).
  • Page 11: Troubleshooting

    6. Troubleshooting 6.1 The engine fails to start è Cold engine in "CHOKE" position. Hot engine in Check position of the choke switch “RUN” position.. è If empty, refill making sure not to spill any fuel. Check the fuel level è...
  • Page 12: Annual Maintenance

    (See Honda manual). Firmly tighten the dipstick. * Hydraulic oil. Check the hydraulic oil level. Use only the hydraulic oil specified by HOLMATRO. Check with your Holmatro Dealer for the recommended hydraulic oil that may be used with Holmatro rescue tools.
  • Page 13: Long Term Storage

    Check the level. 7.6 Five year maintenance and testing * We advise you to have the unit checked and tested by your dealer certified by Holmatro after a maximum of five years of use. Consult your dealer for further details.
  • Page 14: Technical Information

    Only qualified persons authorized by Holmatro may make repairs to and/or service Holmatro® rescue tools. Only an active and presently authorized Holmatro dealer may disassemble the sealed parts. Contact your dealer for further advice if other problems occur. In the event that you are unable to contact your dealer, contact Holmatro at: Holmatro, Inc.
  • Page 15 (2) loss or damage arising out of the sole or contributory negligence of the purchaser, its employees or agents, or any third party, or (3) any special or punitive damages of any nature. If Holmatro determines, in its sole and final discretion, that the nature of the defect precludes remedy by repair and/or replacement, Holmatro reserves the right to satisfy any warranty obligation by refunding the full purchase price, on return of all defective goods to Holmatro, shipping costs prepaid.
  • Page 16 HOLMATRO DEALER: TEL: FAX: TOOL SERIAL NUMBER: SERVICE RECORD: DATE REPAIR/SERVICE SERVICE DESCRIPTION TECHNICIAN Please make copies of this sheet as needed for future use.