Troubleshooting; Post Error Messages - Dell 6 series User Manual

Poweredge expandable raid controller
Table of Contents

Advertisement

Troubleshooting

To get help with your Dell™ PowerEdge™ Expandable RAID Controller
(PERC) 6 and Dell Cost-Effective RAID Controller (CERC) 6/i controller,
you can contact your Dell Technical Service representative or access the
Dell Support website at support.dell.com.

Post Error Messages

The controller BIOS read-only memory (ROM) provides Int 13h functionality
(disk I/O) for the virtual disks connected to the controller. You can boot from
or access the physical disks without the need of a driver. Table 7-1 describes
the error and warning messages for the BIOS. Table 7-2 describes the error
messages for the Battery Backup Unit (BBU).
Table 7-1. BIOS Errors and Warnings
Message
BIOS Disabled. No Logical
Drives Handled by BIOS
Press <Ctrl><R> to Enable
BIOS
Meaning
This warning message displays after you
disable the ROM option in the
configuration utility. When the ROM
option is disabled, the BIOS cannot boot
to INT 13h and cannot provide the ability
to boot from the virtual disk.
Int 13h is an interrupt signal that supports
numerous commands that are sent to the
BIOS, then passed to the physical disk.
The commands include actions you can
perform with a physical disk, such as
reading, writing, and formatting.
When the BIOS is disabled, you are given
the option to enable it by entering the
configuration utility. You can change the
setting to Enabled in the configuration
utility.
Troubleshooting
113

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge perc 6/iPoweredge perc 6/e

Table of Contents