Product Name: CT101 NOTE: Append this Opera- Document Title: CT101 Operation Guide Document Type Code: IBOE tion IB to the Install IB to Part Number: 1202-004-002 make one IB-booklet. Need a divider tab between the 2 20apr12 Iris inclusion text added mtf 9apr12 bs edits mtf sections.
Page 2
Operation Guide CT101 The CT101 communicating Z-Wave thermostat operates via a high-quality, easy-to-use touch screen. To set or adjust your CT101, simply touch your finger top cover firmly to the screen. The screen will automatically light up and you will hear a “beep.” Do not use a sharp or...
Page 3
To pair with an Iris system please follow instructions below ™ Your new thermostat needs to be paired to an Iris™ system to leverage the Iris™ service. Follow the instructions below depending on whether this is an upgrade to an existing system, or you are installing your thermostat as part of a new Iris™...
HOME Screen Control Screens Before you operate the CT101 please get familiar with these basic control screens. All the CT101 functions are accessed through these screens: HOME, MENU, and MANUAL. The CT101 touch screen technology allows you to select (by touching) an item and change it using the +/- arrows or the time arrows.
MENU Screen The MENU screen is the gateway to many functions or settings of the CT101. It is displayed when you press the MENU button. [See page 10 for details] Chirp set Differential to set RECOVERY set Set Time Touch this to turn the for 2nd Stage start.
For manual programming please see below PROGRAM Screen The stand alone PROGRAM screen sets the CT101 control for your home HVAC system without using an Iris™ system. Return HOME When programming is Set Time Slot complete touch this to run your program Touch this area to set the and return to the HOME screen.
MANUAL Screen The Manual Screen control screen is where you can make temporary changes to your CT101’s operation. From the HOME screen, touch the main temperature display to use this screen. [See page 13 for details] Temp Up / Temp Down arrows...
Page 8
Initial Settings Press MENU to access the following commands (from HOME screen). Set time of day Touch the Time of Day arrows to move the time selection forward or backward until it displays the current time. Touch and hold for faster setting. Backward Forward Set o F- o C display...
All Days TO CHANGE THE PROGRAM: Make sure the CT101 mode is set to either HEAT or COOL, then press the PROGRAM button. This puts you at the PROGRAM screen [see page 4]. The programmed start time is displayed in the upper left.
Page 10
PROGRAM cont. Select the day you want to program. The day of the week starts at SU - Sunday and can be advanced to the day you want to program. Touch the day of the week area to cycle through the days of the week to the desired day. Select the time slot (period) you want to program (MORN, DAY, EVEN, NITE).
Page 11
0.5 to 4.0F (.25 to 2C). For example, if SWING is set to 2.0° F and the CT101 is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F. Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC then runs and will shut off at the Target Temperature.
Page 12
Touch icon for 5 seconds; the unit will go into the PARTIAL lock mode. The user can temporarily override the CT101 target with the +/- buttons only. (1 bar) For FULL lock : Touch the (1 bar) icon again for 5 seconds to go to full lock. No changes can be made in full lock (2 bars).
Page 13
CALIBRATE Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient temperature. You do have the option, however, to change the display temperature to match that of a previous thermostat, or to match another thermostat already in your home. The range of change is from -6°F to +6°F or -3°C to +3°C.
Page 14
EMER (in HEAT PUMP type) If you set your CT101 for HEAT PUMP with auxiliary heat, EMER function is available on the MANUAL screen. If you touch EMER, it displays EMER|ON. Your HEAT PUMP is disabled and auxiliary heat is your sole source of heat.
The mode button sets the CT101 to HEAT, COOL, AUTO, or OFF modes. Press it once to step to the next mode. If the CT101 is in OFF and you want to return to the mode you were previously in, touch the OFF indicator on screen.
Page 16
When your thermostat is running on battery power, the Z-Wave radio will turn off to help conserve battery life. The CT101 Z-Wave radio module supports Z-Wave beaming, which allows other devices in the network to wake up the Z-Wave module and accept commands, and then go back to sleep.
Page 17
Z-Wave and C-Wire Power When your thermostat is running on C-Wire power, the Z-Wave radio will stay on and actively help in routing messages within the z-wave network. The node type is fixed during network inclusion. If C-Wire is present and powered during network inclusion, the thermostat will remain an always listening node until the thermostat is removed from the network via network exclusion.