Cleaning And Maintenance - Honeywell TrueSTEAM Operating Manual

Hide thumbs Also See for TrueSTEAM:
Table of Contents

Advertisement

Cleaning and maintenance

About your new thermostat
Maintenance is made simple with the TrueSTEAM—just remove the water tank for cleaning.
Warning: Scalding hazard.
Do not attempt to remove the humidifier from the mounting bracket during operation, or
the humidifier's water tank when full of water. The heating element could be hot when
tank is removed. Failure to comply could result in severe scalding or death.
To clean TrueSTEAM:
1. Press the EMPTY button. Wait for the CLEAN TANK light to be on solid (not blinking).
EMPTY
M24774
2. Turn the manual shut-
off valve at the bottom
of the tank to the
"Unlock" position.
CLEAN TANK
(BLINKING LIGHT)
3. Grip the white water
valve arm and slide it
back within the bracket
to disengage from the
tank.
M24777
TrueSTEAM Direct-Injection Humidifier
Wait
M24775
M24779

Go to Step 2
CLEAN TANK
(ON SOLID)
4. Firmly grip the tank
bottom. Push down the
cover's safety button and
pull the latch forward to
release the tank.
Note: Latch does not come
off humidifier with tank.
69-2035EFS—0
M24776
M24778

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TrueSTEAM and is the answer not in the manual?

Questions and answers

Jared
February 22, 2025

My Triusteam keeps filling and draining continuously. I’ve counted as many as 4 cycles. The celenoid seems to be working in that it shuts off when filling then opens up to drain. Thanks for any advice.

1 comments:
Mr. Anderson
February 22, 2025

The Honeywell TrueSTEAM may keep filling and draining continuously due to a faulty solenoid valve, a water level sensor issue, or incorrect wiring. If the solenoid is malfunctioning, it may not properly control water flow, causing continuous filling and draining. Checking the solenoid for proper operation, ensuring correct wiring connections, and verifying that the water level sensor is functioning correctly can help resolve the issue.

This answer is automatically generated