CD MECHANISM SECTION
Perform steps 1, 2, 3, 10,11,12 and 13 of the disassembly
method to remove the CD mechanism.
How to remove the loading motor
(See Fig. 13-1)
1. Bend the hooks (A1) x 5 pcs., to remove the loading motor.
2. Remove the drive belt (A2) x 1pc.
How to remove the pickup (See Fig. 13-2)
1. Remove the stop washer (B1) x 1 pc., to remove the gear
(B2).
2. Remove the screws (B3) x 2 pcs., to remove the shaft (B4).
3. Remove the pickup.
Note
After removing the connector for the optical pickup from the
connector wrap the conductive aluminium foil around the front
end of connector so as to protect the optical pickup from
electrostatic damage.
MECHANISM SECTION
Driving Force Check
Torque Meter
Play: TW-2111
Torque Check
Torque Meter
Play: TW-2111
30 to 80 g.cm
Fast forward: TW-2231
Rewind: TW-2231

ADJUSTMENT

Specified Value
Tape 1: Over 80 g
Tape 2: Over 80 g
Specified Value
Tape 1
Tape 2
30 to 80 g.cm
70 to 180 g.cm
70 to 180 g.cm
CD Player
Chassis
(B1) x2
ø2.6 x6mm
Shaft
(B2) x1
Tape Speed
Test Tape
Normal
MTT-111
speed
TAPE MECHANISM
Variable Resistor in motor
– 13 –
CD-BA250/CD-BA2600
Loading Motor
(A1)x2
Loading
Motor
Pulley
Drive Belt
(A2) x1
Figure 13-1
Stop Washer
(B3) x1
CD Mechanism
Gear
(B4) x1
Figure 13-2
Adjusting
Specified
Value
Point
Variable
3,000
30 Hz
Resistor in
motor.
Tape
Motor
Figure 13-3
(A1)x1
(A1)x2
Pickup
Instrument
Connection
Speaker
terminal
(Load
resistance:
6 ohms)