Chapter 5

CE Show Auto Boot

This command shows the state of the Auto Boot parameter for a specific CE. Auto Boot allows
the CE to automatically boot the CE's Windows NT operating system after a reboot or power
cycle. By default, Auto Boot is true (enabled).
Command
CEn Show Auto Boot From IOPx
Console Syntax MTCCONS CEn Show Auto Boot From IOPx
Variables
n – the ID number of the CE (1 or 2)
x – the ID number of the IOP (1 or 2)
The value for Auto Boot is displayed as either: true (enabled) or false
Results
(disabled). For an example of the results of this command, refer to
Parameters (page
See Also
CE Disable Auto Boot
CE Enable Auto Boot
CE Show Parameters

CE Show Auto Synch

This command shows the state of the Auto Synch parameter for a specific CE. Auto Synch
allows the CE to automatically synchronize with the other CE after a reboot. If you disable Auto
Synch, you cannot synchronize that CE until you issue a CE Enable Auto Synch command. By
default, Auto Synch is true (enabled).
Command
CEn Show Auto Synch From IOPx
Console Syntax MTCCONS CEn Show Auto Synch From IOPx
Variables
n – the ID number of the CE (1 or 2)
x – the ID number of the IOP (1 or 2)
The value for Auto Synch is displayed as either: true (enabled) or false
Results
(disabled). For an example of the results of this command, refer to
Parameters (page
See Also
CE Disable Auto Synch