Technical Specifications - HP D6000 Specification

Hp d6000 disk enclosure
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

D6000
Power Consumption
(maximum)
INPUT POWER
(per power supply)
TEMPERATURE AND
HUMIDITY RANGES
PHYSICAL
Power consumption at 208VAC
Drive Type
7200 RPM SAS MDL
10K 400G SAS
15K SAS
NOTE: Input Power and Heat Dissipation specifications are maximum values and apply to worst-case
conditions at full rated power supply load. The power/heat dissipation for your installation will vary
depending on the equipment configuration.
NOTE: Temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000
ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. The upper limit may be limited by the
type and number of options installed.
NOTE: Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude
maximum for storage corresponds to a pressure minimum of 70 KPa.
NOTE: The "service position maximum" column is the test result with the drawers open.
Upgradeable Firmware
Disk Drives and Enclosure
Protocol Support
DA - 14419 Worldwide — Version 6 — December 9, 2013
Rated Line Voltage
Rated Input Frequency
Rated Input Current
Rated Input Power
Operating Temperature
Storage Temperature
Operating Humidity
Non-Operating Humidity 5% to 95% relative humidity (Rh), 38.7º C (101.66º
Length
Width
Height
Chassis
Weight
Typical
1035W (3532 Btu/hr)
940W
1280W
Offline
HP 3.5" SAS and SAS MDL 6 Gb/s
HP D6000 Disk Enclosure
90 to 132 VAC 180 to 264 VAC
47 to 63 Hz
10A (at 100 VAC), 7.8A (at 200VAC)
@ 100VAC, 70 drives x 2TB-7.2K = 1043.7W
@ 100VAC, 70 drives x 600GB-15K = 1601.9W
50° to 95° F (10° to 35° C)
NOTE: Maximum Rated 10°C per/hr (50°F/hr)
-22° to 140° F (-30° to 60° C)
NOTE: Maximum Rated 20°C/hr (68°F/hr)
10% to 90% relative humidity (Rh), 28º C (82.4º F)
maximum wet bulb temperature, non-condensing
F) maximum wet bulb temperature, non-
condensing
89.12 cm
44.7 cm (17.6 in)
22.1 cm (8.7 in)
72.58 kg (160 lb) with no hard drives installed
145 kg (320 lb) with hard drives installed
Service Position Maximum
(drawers being pulled out causing
all fans to go to full speed
1470W (5021 Btu/hr)
1340W
1710W
Page 13

Advertisement

Table of Contents
loading

Table of Contents