10.Después de darle servicio a los filtros
PERMAtech™ reactive el indicador
presionando por 2 segundos el botón
que está en el panel de control.
Vida útil del filtro (
). El filtro está
diseñado para que nunca necesite
cambiarse, pero si requiere servicio.
Para mantener el rendimiento óptimo
de esta unidad, recomendamos que
bajo condiciones normales de uso
continuo, se limpien los filtros por lo
menos cada 3 meses.
INSTRUCCIONES DE LIMPIEZA para los filtros PERMAtech™
Problema
Solución
La unidad no
• Cerciórese que la unidad esté bien enchufada
• Cerciórese que la unidad esté encendida
enciende
presionando el botón interruptor.
• Si la luz indicadora se enciende, deben
limpiarse los filtros PERMAtech™.
Poco flujo de aire
• Revise que los filtros estén en buenas
condiciones.
• Asegúrese que la toma y la salida de aire no
estén obstruidas.
Ruido
• Verifique que los filtros no est.n dentro de
bolsas.
S6
Si los filtros se dañasen durante la
limpieza, obtenga otros de repuesto
llamando al 1-877-207-0923
Modelo
Cantidad
de
de filtros
Descripción
Filtro No.
Purificado
que usa
del Filtro
r de aire
169018
2
7400000000203
Filtre PERMAtech
MC
16901805EFSM2
9100040001819
PLEASE READ
greater than the rating of the air purifier.
Care must be taken to arrange the
AND SAVE
extension cord so that it will not drape
over the countertop or tabletop where it
THESE
can be pulled on by children or
accidentally tripped over.
IMPORTANT
Thank you for choosing a GE
purifier. To ensure the best performance
SAFETY
from your air purifier, please read and
save the following instructions.
INSTRUCTIONS
IONIZER
CONSUMER SAFETY
Your Air Purifier has an independently
INFORMATION
controlled ionizer, which, when turned
on, releases negative ions into outgoing
NOTE: This is an electrical appliance and
filtered air. Ions are tiny particles that
requires attention when in use.
carry a positive or negative charge. These
NOTE: DO NOT block air intake grill or
ions exist naturally around us, in the air,
filtered air outlet.
water and ground. Both positive and
negative ions are colorless, odorless and
THIS PRODUCT IS EQUIPPED WITH A
completely harmless.
3-PRONG PLUG. This product is for use
Negative ions help the air purification
on 120 volts. The cord has a plug (A) as
process by attaching themselves to very
shown. An adapter (C) is available for
small airborne particles in the room.
connecting three-blade grounding-type
These particles take on a negative charge
plugs to two-slot receptacles (B). The
and may join with positively charged
green grounding plug extending from the
adapter must be connected to a
particles such as dust, pollen, smoke and
permanent ground such as a properly
pet dander to form larger particles that
grounded outlet box. The adapter should
are then more readily captured by the
not be used if a three-slot grounded
filter system, or they may be attracted to
receptacle is available.
positively charged surfaces like walls or
floors.
You may also note after extended use, that
dust may have collected around the grills
or front panel. This is from the ionization
affect caused by the negative ions exiting
from the air outlet. This is additional
evidence of the air cleaning effectiveness
of negative ions. The dust can be easily
Cord and Plug Installation Safety
removed with a clean, damp cloth or soft
Instructions
brush.
The length of cord used on this appliance
NOTE: It is important to clean the
was selected to reduce the hazards of
PERMAtech
becoming tangled in, or tripping over a
intervals. Using the ionizer in conjunction
longer cord. Because of potentail safety
with dirty filters may result in dirty
hazard under certain conditions, we
particles exiting the air purifier and being
strongly recommend against the use of an
attracted to walls, carpets, furniture or
extenstion cord. However, if you must use
other household objects. These dirty
an extension cord, it is absolutely
particles may prove very difficult to
necessary that it is a UL-listed, 3-wire
remove.
grounding type appliance extension cord
having a grounding type plug and
outlet.The electrical rating of the
extension cord must be equal to or
®