4A. POWER CORD CONNECTIONS
(4-Wire Connection
Instructions - Refer to Fig.12)
Before wiring the range review the suggested power source location
drawing in Fig. 3. If connecting to a 4-Wire electrical system (new
branch-circuit
or mobile home requires 4-Wire connection):
1.
Follow the manufacturer's installation instructionssupplied with
the strain relief and install (Also see Figs. 9, 10 & 11).
2.
insert the end connectors for Line 1, Line 2 and Neutral and
tighten securely to the terminal block.
IMPORTANT
NOTE: DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if
these 3 nuts are loosened or removed.
3.
You must disconnect
the ground strap. Remove the factory
installed ground screw & plate to release the copper ground strap
from the frame of the appliance. Cut and discard the copper
ground strap & plate. KEEP the ground screw.
4.
Connect the ground wire (Green) lead with the eyelet to the
frame of the appliance with the ground screw using the same
hole in the frame where the ground screw was originally installed
(See Fig. 12).
5.
Make sure all screws are tightened securely and replace the rear
access cover (See Fig. 9).
or 4B. POWER CORD CONNECTIONS
(3-Wire Connection
Instructions.
For existing installations
ONLY -
Refer to Fig. 13).
1.
Follow the manufacturer's
installation instructions supplied with the
strain relief and install (Also see Figs. 9, 10 & 11).
2.
insert the end connectors for Line 1, Line 2 and Neutral and tighten
securely to the terminal block (See Fig. 13).
IMPORTANT
NOTE: DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3
nuts are loosened or removed.
3.
Make sure all connections are tightened securely and replace the
rear access cover (See Fig. 9).
Grounding
Instructions
(3-Wire Connections
only):
A ground strap is installed on this range which connects the center
terminal of the terminal block (Neutral) to the range chassis. The
ground strap is connected to the range by the center, lowest screw
(See Fig. 13). The ground strap must not be removed unless
National, State or Local Codes do not permit use of a ground strap.
NOTE: if the ground strap is removed for any reason, a separate
ground wire must be connected to the separate ground screw
attached to the range chassis and to an adequate ground source.
Separate StTain Relief
before installa'don
Fig. 11
4-Wire Connection
Factory Installed €onnections (DO NOT LOOSEN)
Terminal
Connect
Line I
Connect
Neutral
(White or
Cut Ground
Stm!
Ground Strap
& Ground Plate
Connect Green
Ground
Wire with
Ground
Screw here
NOTES:
InStall Strain-Relief
Bushing. Center or whim
wire must always be
attached to the center
termlnel on block
Connect
, Line 2
here
Fig. 12
3-Wire
Connection
Factory Installed connections (DO NOT LOOSEN)
Terminal
Connect
Line 1
here
Connect
(White or
Center) here
NOTES:
Install Strain-Rebel
Bushing. Center or white
wire must always be
sttoched to the center
ten_lnnl on block.
Connect
Line 2
here
Fig. 13