Kenmore 30 " ELECTRIC RANGE Installation Instructions page 3

30" electric range
Hide thumbs Also See for 30 " ELECTRIC RANGE:

Advertisement

2b.
MODELS
REQUIRING
POWER
SUPPLY
CORD
KIT.
RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IFAN
INCORRECT
SIZE RANGE CORD KIT IS USED, THE
INSTALLATION
INSTRUCTIONSARE
NOT FOLLOWED OR
STRAIN RELIEF BRACKET IS DISCARDED.
This appliance may be connected by means of a power supply
cord. Only a power supply cord kit rated at 125/250 volts
minimum, and marked for use with ranges shall be used. See Fig.
10 for cord kit ampere rating information. Cord must have either
three (3) or four (4) conductors (See Fig. 8). Terminals on end of
wires must be either closed loop or open-end spade lugs with
upturned ends. Cord must have strain relief properly installed. See
Steps 4a. for 4-Wire or 4b. for 3-Wire connections.
Separate
Strain Relief
before installation
Fig, 11
3. ELECTRICAL
CONNECTION
TO RANGE.
The Rear Access Cover must be removed (Fig 9). To remove,
loosen center screw (one screw) and remove cover. The terminal
block will then be accessible.
3 & 4 - Wire electrical
wail Receptacle types &
Required for new and
remodeled installations
4 Wire Wall
Receptacle
(14-50R)
Fig. 8
Allowed for
exisiting installations
3 Wire Wall
Receptacle
(10-50R)
NOTE:
Range is shipped from factory with 1-3/8" dia. hole as
shown. To use either 7/8" dia. hole or 1-1/8" dia. knockouts refer
to Fig. 9.
1-1/8" Dia.
7/8" Dia.
Knockout
Hole
(See Chart)
(See Chart)
_:R_ar
Mounting
A_ess
Plate
Cover
1-3/8"
Pocket
Hole
for Cable
(See Chart)
Mounting
Plate
Fig. 9
Range
Connection
Opening
Size Chart
Supply Cord Kit ampere rating information,
See serial plate on range
for kilowatt
rating
data.
See Serial Plate on Range for
KW Rating
120/240 Volts 120/208
Volts
Cord Kit
Ampere
Rating
8,8-16,5
KW
7.9q2.5
KW
40/50 Amp
16.6-22.5
KW
12,6-18,5
KW
50Amp
Fig.
10
Diameter
(inches)
of Range
connection
Opening
Permanent
Cord Kit
Wiring
1-3/8 in,
1-1/8 in.
1-3/8
in.
1-3/8 in.
4A. POWER
CORD
CONNECTIONS
(4=Wire Connection
Instructions
- Refer to Fig.12)
Before wiring the range review the suggested power source
location drawing in Fig. 3. If connecting to a 4-Wire electrical
system (new branch-circuit
or mobile home requires 4-Wire
connection):
1.
Follow the manufacturer's
installation instructions supplied
with the strain relief and install (Also see Figs. 9, 10 & 11 ).
2.
Insert the end connectors for Line 1, Line 2 and Neutral and
tighten securely to the terminal block.
iMPORTANT
NOTE:
DO NOT LOOSEN the factory
installed nut connections which secure the range wiring to the
terminal block. Electrical failure or loss of electrical
connection may occur if these 3 nuts are loosened or
removed.
3.
You must disconnect
the ground
strap.
Remove the
factory installed ground screw & plate to release the copper
ground strap from the frame of the appliance. Cut and
discard the copper ground strap & plate. KEEP the ground
screw.
4.
Connect the ground wire (Green) lead with the eyelet to the
frame of the appliance with the ground screw using the same
hole in the frame where the ground screw was originally
installed (See Fig. 12).
5.
Make sure all screws are tightened securely and replace the
rear access cover (See Fig. 9).
4-Wire
Connection
Factory
installed
connections
(DO NOT LOOSEN)
Terminal
Connect
Line 1
Connect
here
Connect
here
Neutral
(White or
Center)
Cut Ground
Strap. Discard
Ground Strap
& Ground Plate
Connect
Green
Insulated
Copper
Ground
Wire with
Ground
Screw
here
NOTES:
Install Strain-Relief
Bushing, Center or white
wire must always be
Fig.
12
attached to the center
terminal on block

Advertisement