Fujitsu AOU18RLXFZ Manual page 4

Mini-split air conditioners and heat pumps
Hide thumbs Also See for AOU18RLXFZ:
Table of Contents

Advertisement

Multi-Zone Outdoor Units
AOU18RLXFZ, AOU24RLXFZ, AOU36RLXFZ
AOU36RLXFZ
AOU18, 24RLXFZ
Compact Size
The compact size of the outdoor
units allows for many installation
opportunities.
24" minimum
clearance
required
DC Twin Rotary
Compressor
A high perform-
ance, low noise,
large capacity
DC twin rotary
compressor is
used.
Nominal Capacities, SEER and HSPF Ratings
Data below is based on AHRI 210/240 non-ducted wall mounted models.
Model
Type
Non-Ducted
Ducted
Mixed
AOU18RLXFZ
Specific
Non-Ducted
AOU24RLXFZ
Ducted
Mixed
Non-Ducted
AOU36RLXFZ
Ducted
Mixed
Yellow rows represent models that are ENERGY STAR
4
18, 24 and 36,000 BTUs
Connectable Indoor Unit
Connectable Unit Capacity Class BTU/h
Rated Capacity Cooling/Heating
Clg. Operating Range °F(°C)
Htg. Operating Range °F(°C)
Input Power: Clg/Htg Rated kW*
Voltage/Frequency/Phase
Current: Total Max.
Minimum Circuit Ampacity
Recommended Fuse Size
Outdoor Fan Airflow CFM
Fan: Type x Quantity
Sound Pressure Level Cooling
Sound Pressure Level Heating
Pre-Charge Length Total Ft (m)
Max. Length Total Ft (m)
Max. Length Each Ft (m)
Min. Length Total Ft (m)
Min. Length Each Ft (m)
Max. Pipe Height Difference Between
Outdoor Unit & Farthest Indoor Ft (m)
Max. Pipe Height Difference
Between Indoor Units Ft (m)
Connection Method
Conn. Pipe Diameter
Net Weight lbs.
Dimensions: Height
2
See Design & Technical Manual for allowed combinations within this connectable capacity range.
Cooling
Indoor Unit
Capacity
Btu/h
95 ◦ F
Combination
ASU9+ASU9
18,000
-
18,000
-
18,000
ASU7+ASU12 and
18,000
ASU9+ASU12
ASU9+ASU7+ASU7
22,000
-
22,000
-
22,000
-
35,200
-
33,800
-
34,400
®
Qualified.
AOU
18RLXFZ
24RLXFZ
Heat Pump
Heat Pump
ASU9+ASU9
ASU9+ASU7+ASU7
2
Number
14 to 21,000
14 to 27,000
2
18,000/22,000 22,000/24,000 35,200/36,400
BTU/h
14 to 115
14 to 115
(-10 to 46)
(-10 to 46)
5 to 75
(-15 to 24)
(-15 to 24)
1.44/1.87
1.76/1.73
208-230/60/1 208-230/60/1
10.0
(A)
13
(A)
25
(A)
1,795/1,619
1,942/1,942
(Clg/Htg)
Propeller x 1
Propeller x 1
49
dB(A)
49
dB(A)
98 (30)
164 (50)
164 (50)
82 (25)
49 (15)
16 (5)
49 (15)
33 (10)
Flare
Liq. 1/4 x 3
Liq. 1/4 x 2
Suc. 1/2 x 1,
Inch
Suc. 3/8 x 2
(kg)
119 (54)
124 (56)
Inch
27-9/16
mm
700
Width
Inch
35-7/16
mm
900
Depth
Inch
13
330
mm
R410A
Refrigerant
1
18+18 is the only 2 indoor unit (ASU, ARU or AUU) combination and requires K9FZ1818.
EER
SEER
12.50
18.0
12.10
16.0
12.30
17.0
12.50
18.0
12.50
18.0
10.60
15.5
11.55
16.8
8.80
16.0
8.10
14.5
8.45
15.3
AOU
AOU
36RLXFZ
36RLXFZ
Heat Pump
18+18 Combo
ASU9 x 4
ASU18+ASU18
2 to 3
3 to 4
27 to 39,000
2
2
31,600/35,800
32 to 115
50 to 115
(0 to 46)
(10 to 46)
5 to 75
14 to 75
(-10 to 24)
(-10 to 24)
4.00/3.00
3.98/3.66
208-230/60/1
208-230/60/1
13.7
20.1
17
25
25
30
2,119/2,237
2,119/2,237
Propeller x 1
Propeller x 1
51
53
52
55
98 (30)
164 (50)
230 (70)
131 (40)
82 (25)
82 (25)
49 (15)
66 (20)
16 (5)
16 (5)
49 (15)
49 (15)
33 (10)
33 (10)
Flare
Flare
Liq. 1/4 x 4
Liq. 3/8 x 2
Suc. 1/2 x 1,
Suc. 1/2 x 2
3/8 x 2
3/8 x 3
149 (68)
149 (68)
27-9/16
32-11/16
32-11/16
700
830
35-7/16
35-7/16
900
900
13
13
330
330
R410A
R410A
Heating Capacity
COP
Btu/h
47 ◦ F
17 ◦ F
47 ◦ F
22,000
13,900
3.44
22,000
13,900
3.52
22,000
13,900
3.48
22,000
13,900
3.67
24,000
14,100
4.04
24,000
14,100
3.42
24,000
14,100
3.74
36,400
22,000
3.56
36,400
21,200
3.08
36,400
21,600
3.32
AOU
1
2
1
36,000
1
14 to 75
20.1
25
30
53
55
66 (20)
82 (25)
49 (15)
25 (7.5)
49 (15)
33 (10)
Flare
1
830
35-7/16
900
13
330
R410A
HSPF
9.3
9.0
9.2
9.0
9.5
9.0
9.3
9.4
8.7
9.1

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AOU18RLXFZ and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF