Advertisement

DAIKIN ROOM AIR CONDITIONER
Operation Manual
FT18JV1B
MODELS
FT25JV1B
FT35JV1B
FTY18JV1B
FTY22JV1B
FTY35JV1B
ENGLISH
DEUTSCH
FRANÇAIS
NEDERLANDS
ESPAÑOL
ITALIANO
EËËHNIKA
PORTUGUES
DANSK
NORSK
SUOMI

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FT18JV1B and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FT18JV1B

  • Page 1 DAIKIN ROOM AIR CONDITIONER FT18JV1B FTY18JV1B MODELS Operation Manual FT25JV1B FTY22JV1B FT35JV1B FTY35JV1B ENGLISH DEUTSCH FRANÇAIS NEDERLANDS ESPAÑOL ITALIANO EËËHNIKA PORTUGUES DANSK NORSK SUOMI...
  • Page 2: Table Of Contents

    CONTENTS READ BEFORE OPERATION I Safety Precautions ..........2 I Names of Parts G Indoor unit, Receiver explanation ....5 G Outdoor unit, Remote controller ....6 I Preparation Before Operation G Remote controller ......... 7 G Indoor unit ............. 8 OPERATION I AUTO •...
  • Page 3: Safety Precautions

    Safety Precautions I Read the following warnings and cautions WARNING carefully before operating the system and Failure to follow a warning is very likely use it correctly. I This manual classifies the precautions to the to result in such grave consequences as death or serious injury.
  • Page 4 G Do not stand or sit on the outdoor unit. Do not place any object on the unit. The object or the person may fall down or drop, causing injury. G Do not place under the indoor or outdoor unit anything which must be kept away from moisture.
  • Page 5 Installation site I To install the air conditioner in the following types of environments, consult the shop. G Places with an oily ambient or where steam or soot occurs. G Salty environment such as coastal areas. G Places where sulfide gas occurs such as hot springs. G Places where snow may block the outdoor unit.
  • Page 6: Names Of Parts

    Names of Parts Indoor unit Front grille Air purifying filter Air inlet Air purifying filters are attached to the inside of the air filters. Grille tab Air outlet Louvre (vertical blades) Indicator lamps The louvre is inside of the air ON/OFF button TIMER lamp (orange) outlet.
  • Page 7: G Outdoor Unit, Remote Controller

    Names of Parts Outdoor unit Air inlet (Back and side) Refrigerant piping and inter-unit cable Earth terminal Air outlet It is inside of this part. Appearance of the outdoor unit may differ from some models. Drain hose Remote controller Transmitter Display It sends signals to the indoor unit.
  • Page 8: I Preparation Before Operation G Remote Controller

    Preparation Before Operation I I I I I Operating the remote controller Remote controller G To use the remote controller, aim the transmitter at the indoor unit. If there is anything to block signals I I I I I Setting the batteries between the unit and the remote controller, such as a curtain, the unit will not operate.
  • Page 9: G Indoor Unit

    Preparation Before Operation Indoor unit I I I I I Setting the clock I I I I I Setting the air purifying filters Open the front grille. Press G Hold the grille by the tabs on the two sides and lift it until it stops with a click. is displayed.
  • Page 10: I Auto • Dry • Cool • Heat • Fan Operation

    AUTO • DRY • COOL • HEAT • FAN Operation I I I I I To change the air flow rate setting: The air conditioner operates with the settings of your choice. Press FAN . From the next time on, the air conditioner will operate with the same settings.
  • Page 11: I Adjusting The Air Flow Direction

    Adjusting the Air POWERFUL Flow Direction Operation You can adjust the air flow direction to increase POWERFUL operation quickly maximizes the your comfort. cooling (heating) effect in any operation mode. Adjusting the horizontal You can get the maximum capacity with a touch blade (flap) of a button.
  • Page 12: G Off Timer Operation

    Timer Operation Timer functions are useful for automatically ON TIMER operation switching the air conditioner on or off at night or G Check that the clock is correct. If not, set the in the morning. You can also use OFF TIMER clock to the present time (See page 8).
  • Page 13: Care And Cleaning

    Care and Cleaning Cleaning the indoor and outdoor CAUTION units and the remote controller Before cleaning, be sure to stop the operation and turn the breaker OFF. G Wipe them with dry soft cloth. For cleaning, do not use water hotter than 40°C, benzine, gasoline, thinner, nor other volatile Cleaning the air filters oils, polishing compound, scrubbing brushes...
  • Page 14: Cleaning The Front Grille

    Care and Cleaning Check Cleaning the front grille Check that the base, stand and other You may remove the front grille for cleaning. fittings of the outdoor unit are not CAUTION decayed or corroded. G When removing or attaching the front grille, use a Check that nothing blocks the air robust and stable stool and watch your steps carefully.
  • Page 15: Trouble Shooting

    Trouble Shooting G G G G G These cases are not troubles. The following cases are not air conditioner troubles but have some reasons. You may just continue using it. Case Explanation G This is to protect the air conditioner. Operation does not start soon.
  • Page 16: G Check Again

    Trouble Shooting G G G G G Check again Please check again before calling a repair person. Case Check G Hasn’t a breaker turned OFF or a fuse blown? The air conditioner does not G Isn’t it a power failure? operate.
  • Page 17: G Call The Service Shop Immediately

    Trouble Shooting G G G G G Call the service shop immediately. WARNING I When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF. Continued operation in an abnormal condition may result in troubles, electric shocks or fire.
  • Page 18: G Fault Diagnosis

    Trouble Shooting G G G G G Fault diagnosis FAULT DIAGNOSIS BY REMOTE CONTROLLER IN THE EVENT OF AN ABNORMALITY, THE RELEVANT ABNORMALITY CODE APPEARS FLASHING IN THE REMOTE CONTROLLER'S TEMPERATURE DISPLAY. CODE MEANING NORMAL REFRIGEMENT SHORTAGE POWER FACTOR MODULE ABNORMALITY SYSTEM INCORRECT INTERUNIT WIRING(INTERUNIT) INCORRECT INTERUNIT WIRING...
  • Page 20 3P062628-1L M00B035B (0507) HT...

This manual is also suitable for:

Ft25jv1bFt35jv1bFty18jv1bFty22jv1bFty35jv1b

Table of Contents

Save PDF