Electrical Shock Hazard
Plug intoa grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension
cord,
Failure to follow these instructions can resuJt in death,
Ire, or electrical
shock.
120-Volt, 60-Hz., AC-only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is also recommended that a separate circuit
serving only this dryer be provided.
GROUNDING
INSTRUCTIONS
_' For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of eiectdc shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The pIug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance with al local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the pIug provided with the
dryer: if it wiII not fit the outlet, have a proper outlet insta/ed
by a qualified electrician.
SAVE THESE
iNSTRUCTiONS
Explosion
Hazard
Use a new AGA or CSA approved
gas supply
line.
_nstaH a shut-off
valve.
Securely
tighten
al gas connections.
ff connected
to LP, have a qualified
person make sure
gas pressure
does not exceed 13" (33 cm) water
column.
Examples
of a qualified
person
include:
licensed
heating personnel,
authorized
gas company
personnel,
and
authorized
service
personnel
Failure to do so can resumt in death, explosion,
or fire.
Gas Type
Natural gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate
conversion.
Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate
in the door well of your dryer. If this information
does not
agree with the type of gas available, contact your local Sears
store or Sears Service Center.
LP gas conversion:
Conversion
must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier.
Gas supply line
1/2"IPS pipe is recommended.
%" approved tubing is acceptable for lengths under 20 ft
(6.1 m) if local codes and gas supplier permit.
Must include V8"NPT minimum plugged tapping accessible
for test gauge connection,
immediately upstream of the gas
connection to the dryer (see following illustration).