Download Print this page

GE DNCK440EA1WC Installation Manual

Advertisement

Quick Links

Installation
Instructions
Electric D ryer
37
I
Questions
on Installation?
Call: 1-8OO-GECARES
(US)
or Visit our Web site at: www.GEAppliances.com
(US)
BEFOREYOU BEGIN
Read
these
instructions
completely
and
carefully.
•IMPORTANT
- Save these
instructions
for local inspector's
use.
•IMPORTANT
- Observe
all
governing
codes and ordinances.
• Note
to Installer
- Be sure to leave these
instructions
with
the customer.
• Note
to Customer
- Keep
these instructions
with your Use
and Care Book for furore
reference.
• Exhausting
the dryer
to the outdoors
is strongly
recom-
mended
to prevent
large amounts
of moisture
from being
blown
into the room.
• Before
the old dryer
is removed
from service
or discarded,
remove
the dryer
door.
• Service
information
and the wiring
diagram
are located
in
the control
console.
• Do not allow children
on or in the appliance.
Close
supervision
of children
is necessary
when
the appliance
is
used near children.
FOR YOUR SAFETY:
WARNING
• Use only rigid metal or flexible metal 4-in. diameter
ductwork for exhausting to tile outdoors. Never
use plastic or other combustible,
easy-to-puncture
ductwork.
• This appliance
must be properly
grounded
and installed
as described
in these instructions.
• Do not install or store appliance
in an area where it
will be exposed to water and/or weather
• Install tile dryer where the temperature
is above ,50°F
for satisfactory operation
of the dryer control system.
NOTE: Installation
and service of this dryer
requires
basic mechanical
and electrical
skills.
It is your responsibility
to contact
a qualified
installer
to make the electrical
connections,
I
TOOLS YOU
WILL NEED
SLIP JOINT PLIERS
[_
FLAT BLADE SCREWDRIVER
PHILLIPS SCREWDRIVER
MATERIALS YOU WILL NEED
4" DIA. M ETAL D UCT
4"
(RECOMMENDED)
DUCT
CLAMPS ( 2)
OR
4"SPRING
CLAMPS ( 2)
4"DIA.FLEXIBLE METAL DUCT
(IFNEEDED)
%
4"DIA. M ETAL
ELBOW
EXHAUST HOOD SAFETY G LASSES
_
3/4"_RELIEF
DUCT TAPE
GLOVES ULRECOGNIZED
DRYER P OWER
CORD KIT
(NOTPROVIDED
WITH DRYER)
ULRATED 120/240V, 30A
WITH 3 OR4PRONGS.
IDENTIFY THEPLUG TYPE
ASPER THEHOUSE
RECEPTACLE
BEFORE
PURCHASING
LINE CORD.
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Prepare the Area and Exhaust for Installation
of
New Dryer (see section 1).
Check and Ensure the Existing External Exhaust is
Clean (see section 1) and Meets Attached
Installation
Specifications
(see section 3).
Remove the Foam Shipping Pads (see section 1).
Move the Dryer to the Desired Location.
Connect the Power Supply (see section 2).
Connect the External Exhaust (see section 4).
Level Your Dryer (see section ,_).
Step 8
Step 9
Check the Operation
of the Power Supply
and Venting.
Place the Owners Manual and the Installation
Instructions
in a Location Where They Will Be
Noticed By tile Owner.
For Alcove or Closet Installation,
see section 6.
For Bathroom
or Bedroom
Installation,
see section 7.
For Mobile or Manufactured
Home see, section 8.
For side or bottom exhaust, see section 9.

Advertisement

loading

Summary of Contents for GE DNCK440EA1WC

  • Page 1 Installation Electric D ryer Instructions Questions on Installation? Call: 1-8OO-GECARES (US) or Visit our Web site at: www.GEAppliances.com (US) BEFOREYOU BEGIN FOR YOUR SAFETY: Read these instructions completely carefully. WARNING •IMPORTANT - Save these instructions for local inspector's use. • Use only rigid metal or flexible metal 4-in. diameter •IMPORTANT - Observe ductwork for exhausting to tile outdoors.
  • Page 2: Installation Instructions

    Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration must be given to provide adequate clearance for installation and service. [] PREPARING FOR INSTALLATION [] ELECTRICAL CONNECTION OF NEW DRYER...
  • Page 3: Installation

    Installation Instructions 1. Turn off the circuit breaker (s) (30 amp) or remove the dryer's [] EXHAUST INFORMATION circuit fuse at the electrical box. 2. Be sure the dryer cord is unplugged from tile wall receptacle. JIIWARNING - USE ONLY METAL 4-IN.
  • Page 4: Exhaust Connection

    Installation Instructions [] EXHAUST CONNECTION STANDARD REAR EXHAUST (Vented above floor level) ,_,WARNING - TO REDUCE RISK OF FIRE OR PERSONAL INJURY: ELBOW HIGHLY • Exhausting the dryer to the outdoors is strongly recom- RECOMMENDED mended to prevent large amounts of moisture from being...
  • Page 5 Installation Instructions, Indoor Exhausting INDOOR EXHAUSTING USING FLEXIBLE METAL DUCTS If rigid allmmtal duct cannot be used, then flexible allmmtal ducting NOTE: MOBILE HOME, BEDROOM, BATHROOM, can be used, but it will reduce the maxinmnl recotmnended duct ALCOVE OR CLOSET INSTALLATIONS length.
  • Page 6 Installation Instructions ADDING NEW DUCT [] DRYER EXHAUST TO RIGHT, LEFT OR BOTTOM CABINET FIXING HOLE I/A, WARNING- BEFORE PERFORMING PORTION "A" THIS EXHAUST INSTALLATION, BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY. PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET.
  • Page 7 Installation Instructions IT0qCHANGING DIRECTION ADDING ELBOW FOR EXHAUST DOOR OPENING THROUGH BOTTOM OF CABINET 1. ()pen tile door and remove tile filler plugs opposite tile • Insert the elbow through tile rear opening and connect it to hinges. _¥ith tile door completely open, remove the the dryer internal duct.
  • Page 8 Notes...