Cables
Cable type
1
1 Power cable
2
3
2 Alarm I/O cable
3 Audio cable
Connecting the power cable to AC 24 V source
Conductor
1.0 mm dia
1.6 mm dia
2.0 mm dia
diameter (mm)
or more
or more
or more
Max cable
distance (meters)
90
240
(Reference value)
Note
For safety reasons, turn on the power only after
confirming that all the connections are completed.
Be sure to turn off the camera before connecting
cables.
If you use both the AC 24 V power cable and the
PoE-based LAN cable simultaneously, the camera
may fail. Always supply power using either method.
To use an AC 24 V power supply, remove the
factory-installed tape from the power cable, connect
to an AC 24 V power supply, and wrap the connector
with new insulation tape and waterproof tape.
Audio cable connection
Connect the audio cable for an audio device.
Audio cable (Brown and White) (MIC IN)
: Connect to a condenser microphone that has a plug-in power
Audio cable (Black and White) (LINE OUT) : Connect to a speaker with a built-in amp, etc.
Memo
A shielded audio cable is recommended.
* For the location to connect the audio cable, refer to [Cabling] (
Alarm I/O cable connection
Alarm input
Connect an infrared sensor, door sensor, metal
sensor, a manual switch or other device.
To avoid noise entering the internal circuit, enter the
non-voltage contact signal in the Alarm IN terminal.
Do not supply voltage.
The alarm can be set to be activated during close
contact (MAKE) or during open contact (BREAK)
can be set from the menu.
The alarm signal should last for at least 500
msec. If the alarm signal is short, it may not be
recognized.
Input conditions
Connect non-voltage a contact or open collector
output circuit
(For details on how to set polarities, please refer to
"Instructions (Setting)".)
Low level terminal current below 1 mA
High level terminal current 3.3 V
This
camera
Sensor example (1)
DC3.3 V
VCC
Input 1 or
Input 2
R
OUT
3.3 V
1 mA
G
G
(Alarm input equivalent circuit)
Sensor example (2)
Relay switch or
other devices
OUT
G
* For connecting the Alarm I/O cable, refer to [Cabling] (
(VN-H257VPU)
Color
Red
AC 24 V
Black
AC 24 V
Red
INPUT 1 (ALARM)
Brown
INPUT 2 (ALARM)
Black
Orange
OUTPUT 1 (ALARM)
Yellow
OUTPUT 2 (ALARM)
Black
GND (ALARM)
White
MIC IN
Brown
Yellow
GND (MIC IN)
White
LINE OUT
Black
Yellow
GND (LINE OUT)
LAN cable
When connecting to a switching hub:
Use a straight cable.
When connecting to a computer:
Use a crossing cable.
370
A 100-meter or less length and Category-5 or higher
grade STP (shielded) cable is recommended.
Note
The crossing cable may not be used for some
computer models. Check the LAN specifications of
the computer when you directly connect this unit to
the computer.
Alarm I/O cable
A 50-meter or less length shielded cable is
recommended.
Attach the supplied ferrite core to the cable.
(VN-H257VPU)
system, etc.
page 2).
(VN-H257VPU)
Alarm output
Connect an alarm device, indicator, lighting, buzzer or
other device.
An alarm output signal is an open collector output.
You can configure the menu to set the alarm to
sound when contacts short circuit (MAKE) or
when the contacts are open (BREAK). (Pressure
resistance lower than 16V, 30 mA)
This terminal has different polarities. The output
voltage at the positive terminal must always be
higher than the output voltage at the negative
terminal. Otherwise, the circuit may be damaged.
Output conditions
Equivalent to NPN open collector output
(For details on how to set the output logic, please
refer to "Instructions (Setting)".)
Safe excitation voltage: DC16 V or lower
Allowable surge current: 30 mA
Momentary (100 ms to 5000 ms) output
(For details on how to set the time, please refer to
"Instructions (Setting)".)
This
camera
Output 1 or
Output 2
G
(Alarm output equivalent circuit)
Note
Connect the G terminal cable of this camera to the
GND of the alarm device.
page 2).
Signal name
Symptom
No monitor image is output.
The external mic sound is not heard.
Movement of network image is not
smooth
Lens is out of focus
* The specifications and appearance of this unit are subject to change for purposes of improvement without prior notice.
Image sensor
Effective pixels
Camera
section
Minimum illuminance
of subject
Monitor output
Input
Audio input
Reference voltage
Impedance
Audio output
Image compression
format
Frame size
Network
output
Audio compression
formats
Network interface
Alarm input
Alarm output
Alarm record
Focal length
Maximum aperture
ratio
Lens
Aperture range
Zoom ratio
Standards
LAN
Communication
standards
protocol
Power supply voltage
Current consumption
Ambient temperature
General
Ambient humidity
Mass
Dustproof/Waterproof IP66 compliant
Alarm device
example
DC12 V
R
IN
VN-H257VPU/VN-H237VPU
External dimensions (unit: mm)
G

Troubleshooting

Causes and Countermeasures
The image output may be turned Off on Internet Explorer.
Check the monitor output setting.
Check the MIC connection.
Is the audio setting turned off? (
If the monitor image output is turned ON, a lower frame rate is set for
network images.
If you turned the monitor image output to OFF, set the frame rate
again.(
"Instructions (Setting)" - "Internet Explorer Setting" -
"Encoding Page")
Is the focus adjustment gear engaged? Check the location of the catch.

Specifications

VN-H257VPU
1/3-inch Square-Pixel Progressive Scan CMOS (elementary color filter)
Approximately 2,120,000 pixels
1944 (H) x 1092 (V)
(50 %, AGC High, 1/30 s)
Color : 0.3 lx (typ.)
Black and White: 0.03 lx (typ.)
75 Ω, 1.0 Vp-p
NTSC or PAL (switch selectable)
Can connect to a microphone
that has a plug-in power system
DC2.47 V (typ.)
2.2 kΩ (typ.)
Line OUT (200 Ω, Max 1.9 Vp-p)
JPEG, H.264 High Profile, H.264 Baseline Profile, MPEG-4
1920 x 1080
1280 x 960
1280 x 720
μ-Law (64 kbps), AD/DA 16 bits,
Fs = 8 kHz, monaural
RJ-45
100BASE-TX/10BASE-T/FULL/HALF/Auto-negotiation enabled
No-voltage a contact input, PNP
open collector input, low level,
latch/momentary (500 msec or
longer) (1 mA circuit current at
low level, and 3.3 VDC applied
voltage at high level)
NPN open collector -output (16
VDC safe excitation voltage, and
30 mA allowable sink current)
16 MB
f = 3 mm to 9 mm
F 1.2 (f =3mm) to F 2.1 (f =9 mm)
F 1.2 to F 360
3 x
Compliant with IEEE802.3, IEEE802.3u and IEEE802.3af
TCP/IP, UDP/IP, FTP, ICMP, ARP, DHCP, SNTP, HTTP, SMTP, RTP,
RTSP, IPv4, IPv6, DSCP, HTTPS, SNMP
AC24 V 50 Hz/60 Hz, or
PoE (DC-48 V)
AC24 V 0.5 A, or PoE 150 mA (7.2 W) 120 mA
-10 °C to 50 °C (Operation)
0 °C to 40 °C (Recommended)
20 %RH to 90 %RH (without condensation)
Approx. 1.3 kg
121
113
9
Screws for duct G3/4-14UNC
(Bottom, side)
160
"Instructions (Setting)"→ "Audio Page")
VN-H237VPU
640 x 480
640 x 360
320 x 240
f = 2.8 to 10.5 mm
F 1.2 (f = 2.8 mm) to
F 2.6 (f = 10.5 mm)
F 1.2 to F 360
3.75 x
PoE (DC-48 V)
LST1236-001D
4

Advertisement

loading

This manual is also suitable for:

Vn-h237vpuVn-h257vpbu