Table of Contents

Advertisement

Available languages

Available languages

Quick Links

MICROWAVE HOOD COMBINATION
INSTALLATION INSTRUCTIONS
This product is suitable for use above electric or gas cooking products up to 36" (91.4 cm) wide.
These installation instructions cover different models. The appearance of your particular model may differ slightly from the
illustration in these installation instructions.
INSTRUCTIONS D'INSTALLATION
DE L'ENSEMBLE FOUR
MICRO-ONDES/HOTTE
Ce produit est congu pour I'utilisation au-dessus d'appareils de cuisson 61ectriques ou _.gaz de 36" (91,4 cm) de largeur
ou moins.
Ces instructions d'installation sont valables pour plusieurs modules. II se peut que I'apparence de votre propre module soit
16g_rement diff6rente de celle montr6e sur les illustrations dans ce document.
Table of Contents / Table des mati@res
SAFETY ..................... 2
..........................................
2
Tools and Parts .....................................................................
2
Location Requirements .........................................................
3
Product Dimensions ..............................................................
3
Electrical Requirements ........................................................
4
............................................
4
Remove Mounting Plate ........................................................
4
Rotate Blower Motor .............................................................
4
Locate Wall Stud(s) ...............................................................
6
Mark Rear Wall ......................................................................
7
Drill Holes in Rear Wall ..........................................................
7
Attach Mounting Plate to Wall ..............................................
8
Prepare Upper Cabinet .........................................................
8
Install Damper Assembly ......................................................
9
Install the Microwave Oven ...................................................
9
Complete Installation ..........................................................
10
.................................. 11
ASSISTANCE ..........................................................................
12
Replacement Parts ..............................................................
t 2
Accessories .........................................................................
12
SleCURITle DE L'ENSEMBLE FOUR .& MICRO-ONDES/HOTTE
...13
EXIGENCES D'INSTALLATION .........................................................
13
Outillage et pieces ...........................................................................
13
Exigences d'emplacement
..............................................................
14
Dimensions du produit ....................................................................
14
15
..................................................
15
D_pose de la plaque de montage ...................................................
15
R_orientation du moteur du ventilateur ..........................................
15
mural ............ 17
Trac_ sur lemur arri_re ...................................................................
18
Pergage de trous dans lemur arriere ..............................................
18
Fixation de la plaque de montage sur lemur .................................
19
Preparation du placard mural ..........................................................
20
Installation du module du clapet anti-reflux .................................... 20
Installation du four & micro-ondes
..................................................
21
Achever I'installation ........................................................................
22
SPleCIFICATIONS/CONCEPTION
DU CIRCUIT D'IeVACUATION.23
ASSISTANCE ......................................................................................
24
Pieces de rechange .........................................................................
24
Accessoires .....................................................................................
24
8206588

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool 8206588

  • Page 1: Table Of Contents

    Install the Microwave Oven ........... Installation du four & micro-ondes ..........Achever I'installation ................ Complete Installation ............VENTING DESIGN SPECIFICATIONS ........11 SPleCIFICATIONS/CONCEPTION DU CIRCUIT D'IeVACUATION.23 ASSISTANCE ................ASSISTANCE ..................Replacement Parts .............. Pieces de rechange ................. Accessories ................. Accessoires ..................8206588...
  • Page 2: Microwave Hood Combination Safety

    MICROWAVE HOOD COMBINATION SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
  • Page 3: Electrical Requirements

    Installation Dimensions NOTE: The grounded 3 prong outlet must be inside the upper cabinet. See "Electrical Requirements" section. Check t heopening where t hemicrowave oven will b einstalled. The location m ust p rovide: • Minimum i nstallation dimensions. See "Installation Dimensions"...
  • Page 4: Installationinstructions

    Recommended: A time-delay fuse or time-delay circuit breaker. A separate circuit serving only this microwave oven. GROUNDING INSTRUCTIONS [] For all cord connected appliances: The microwave oven must be grounded. In the event of an electrical short circuit, grounding reduces the risk of Electrical Shock Hazard electric shock by providing an escape wire for the electric Plug into a grounded 3 prong outlet.
  • Page 5: Rotate Blower Motor

    Remove 2 screws attaching blower motor to back of microwave oven. Roof Venting Installation Only 1. Repeat Step 1 from "Wall Venting Installation Only." 2. Repeat Step 2 from "Wall Venting Installation Only." 3. Repeat Step 3 from "Wall Venting Installation Only." 4.
  • Page 6 Lx}c@e S 'ud(s) NOTE: If no wall studs exist within the cabinet opening, do not 1. Using a stud finder, locate the edges of the wall stud(s) within install the microwave oven, the opening. See illustrations in "Possible Wall Stud Configurations," 2.
  • Page 7: Mark Rear Wall

    Wall Venting Installation Only The microwave oven must be installed on a minimum of I wall Centerline Upper cabinet bottom stud, preferably 2, using a minimum of I lag screw, preferably 2. 1. Using measuring tape, find and clearly mark the vertical centerline of the opening.
  • Page 8: Locate Wall Stud(S)

    Wall Stud at One Corner Hole (Figure 3) A csc! Mou l>ee o W(:s NOTE: Secure the mounting plate to the wall at both bottom 1. With the support tabs of the mounting plate facing forward, corner hobs drilled into the wall studs and/or drywall using either insert a 1/4-20 x 3"...
  • Page 9 5. Cut the 11/2"(3.8 cm) diameter hole at the circular shaded area "G" on the template. This hole is for the power supply cord. ns xs the Mc o7 'e Oven NOTE: If upper cabinet is metal, the supply cord bushing needs to be installed around the supply cord hole, as shown.
  • Page 10 NOTE: Ifmicrowave oven does notneed tobeadjusted, skip 2. Connect vent to damper assembly. steps 7-9. 7. Ifadjustment isrequired, rotate m icrowave oven downward. Using 2 ormore people, liftmicrowave oven offofmounting plate, a nd setaside onaprotected surface. 8. Loosen m ounting plate screws. Adjust mounting plate and retighten screws.
  • Page 11: Venting Design Specifications

    VENTING DESIGN SPECIFICATIONS This section is intended for architectural designer and builder/ Rectangular to Round Transition contractor reference only. NOTE: The minimum 3" (7.6 cm) clearance must exist between NOTES: the top of the microwave oven and the rectangular to round transition piece so that the damper can open freely and fully.
  • Page 12: Assistance

    Recommended Vent Length ASSISTANCE A 31/4"x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used. Call your authorized dealer or service center. When you call, you will need the microwave oven model number and serial number. The total length of the vent system including straight vent, Both numbers can be found on the model and serial number elbow(s), transitions and wall or roof caps must not exceed the...
  • Page 13: Exigences D'installation

    SECURITE DE L'ENSEMBLEFOURA MICRO-ONDES/HOTTE Votre s_curit_ et celle des autres est tres importante. Nous donnons de nombreux messages de securite importants dans ce manuel et sur votre appareil menager. Assurez-vous toujours lire tous les messages de securite et de vous y conformer. Ce symbole d'alerte de securite vous signale les dangers potentiels de deces et de blessures graves &...
  • Page 14: Specifications

    Dimensions & respecter lois de I'installation REMARQUE : La prise de courant a 3 alveoles reliee a la terre dolt _tre situee a I'interieur du placard mural. Voir la section Inspecter I'espace ou le four & micro-ondes sera install& "Specifications electriques".
  • Page 15: Instructionsd'installation

    INSTRUCTIONS DE LIAISON .&.LA TERRE [] Pour tout appareil menager connecte par un cordon de courant electrique II faut que le four & micro-ondes soit relie & la terre. En cas de court-circuit electrique, la liaison & la terre reduit le risque de choc electrique car le courant electrique dispose d'un itineraire direct d'acheminement &...
  • Page 16 2. Conserver ensemble la plaque de support du clapet et la vis. Pour une installation avec d_charge & I'ext_rieur 3. Retirer deux vis fixant le moteur du ventilateur a I'arriere du travers le toit seulement four a micro-ondes. 1. Rep6ter I'etape 1 de "Pour une installation avec decharge murale seulement".
  • Page 17 d® "ff ..(A,,5/d®spo ® xux du co omb(xg® u {s REMARQUE : S'il n'y a aucun poteau du colombage clans la zone 1. Utiliser un detecteur magnetique de clou/vis pour Iocaliser delimit6e par I'ouverture dans le placard mural, ne pas installer le dans I'ouverture les rives des poteaux du colombage mural.
  • Page 18: Identifier La Position Du/Des Poteaux Du Colombage Mural

    Pour une installation avec d_charge murale seulement Le four & micro-ondes dolt _tre fixe sur au moins un poteau du colombage mural, et de preference sur 2 poteaux; on utilise pour cela au moins 1 vis d'ancrage, et de preference 2 vis ou plus. Axe central_ Fond d_card mural...
  • Page 19 Pousser les vis avec ecrou articule & travers le panneau de gypse; visser les vis a la main pour verifier que chaque ecrou Un trou d'angle face _ un poteau du colombage mural articule s'est deploye et prend appui contre le panneau de (Figure 3) gypse.
  • Page 20 Interrompre I'alimentation electrique. Retirer tout le contenu du placard mural. Placer le gabarit "placard mural" contre le fond du placard V@ifier que la lame du clapet anti-reflux manoeuvre librement mural, et le fixer avec du ruban adhesif ou des punaises. et s'ouvre completement.
  • Page 21 4. Alors que I'avant du four & micro-ondes est encore incline, enfiler le cordon d'alimentation a travers le trou de passage perce dans le fond du placard mural. Risque du poids excessif Utiliser deux ou plus de personnes pour d_placer et installer le four a micro-ondes, Le non-respect de cette instruction peut causer une blessure au dos ou d'autre blessure.
  • Page 22 Pour une installation avec d_charge & I'ext_rieur travers le toit seulement 1. Pour I'installation des filtres sur I'appareil, voir le Guide d'utilisation et d'entretien. 1. Inserer le module du clapet anti-reflux a travers I'ouverture decoupee darts le placard, de telle maniere que la patte Iongue du module du clapet anti-reflux puisse glisser sous les pattes d'arrimage relevees de la plaque de support du clapet.
  • Page 23 SPECIFICATIONS/CONCEPTION DU CIRCUIT D'EVACUATION Cette section presente de I'information de reference uniquement, a I'intention des architectes/concepteurs et constructeurs. REMARQUES Raccord de transition rectangulaire/rond • Les materiaux du circuit d'evacuation necessaires & REMARQUE : On doit disposer d'un espace libre de 3" (7,6 cm) I'installation ne sent pas fournis avec I'ensemble four a micro- ou plus entre le sommet du four a micro-ondes et le raccord de...
  • Page 24: Outillage Et Pieces

    De plus on devra utiliser une extension de conduit rectangulaire de 3" (7,6 cm) entre le clapet anti-reflux et le raccord de transition rectangulaire/rond, pour eviter toute entrave a la manoeuvre du clapet anti-reflux. 8206588 4619-656-17992 ©2006, 7/06 All rights reserved.

Table of Contents