INSTALLATION
IBEFORE YOU IIBEOIN
Read these instructions
completely
and carefully.
• IMPORTANT-
Save these instructions
for local inspector's
use.
IMPORTANT-
Observe all
governing
codes
and
ordinances.
• Note to Installer - Be sure to leave these
instructions
with
the customer.
• Note
to Customer
- Keep
these
instructions
for
future
refer-
ence.
• Before the appliance
is removed
from service or discarded,
remove the washer and dryer
door.
• Inspect the dryer exhaust outlet
and straighten
the outlet
walls if they are bent.
• Service information
and the wiring
diagram
are located
at
the access panel.
• Do not allow
children
on or in the appliance.
Close supervi-
sion of children
is necessary
when the appliance
is used
near children.
• Install the appliance
where the temperature
is above 50 ° F
(10 ° C) for satisfactory
operation
of the dryer control
sys-
tem.
Tools You Will
Need
INSTRUCTIONS
@
Exposure to these substances can be minimized further by prop-
erly venting the dryer to the outdoors.
• This appliance
must be exhausted to the outdoors.
• Use only 4" rigid metal ducting for exhausting the appliance
to
the outdoors.
• DO NOT install a clothes dryer with flexible plastic ducting ma-
terials. If flexible metal (semi-rigid or foil-type)
duct is installed,
it must be UL listed and installed in accordance with the instruc-
tions found in the section "Connecting The Dryer To House Vent"
on this Use & Care Guide. Flexible venting materials are known
to collapse, be easily crushed, and trap lint. These conditions will
obstruct dryer airflow and increase the risk of fire.
• Do not install or store this appliance in any location where it
could be exposed to water and or weather.
• Save these instructions. (Installers: Be sure to leave these instruc-
tions with the customer).
In the state of Massachusetts,
installation
must be per-
formed
by a qualifiedor
licensed
contractor,
plumber,
or
gasfitter
qualified
or licensed
by the state.
• When
using ball type gas shut-off
valves, they should
be
T-handle
type.
• A flexible
gas connector,
when used, must not exceed
3
feet.
1/4"
Nutdriver
Hat Blade
Screwdriver
10" Adjustable Wrenches (2)
8"
Pipe Wrench
_
Siip Joint
Pliers
,eve_ "-.._
V_ZARNIING
RISK OF
FIRE
• To reduce the risk of severe injury or death, follow all installation
instructions.
• Appliance installation must be performed
by a qualified in-
staller.
• Install the appliance
according to these instructions and in ac-
cordance with local codes. In the absence of local codes, instal-
lation must comply with National
Fuel Gas Code, ANSIZ223.1/
NFPA 54 or the Canadian Natural Gas and Propane Installation
Code, CSA B149.1.
• California Safe Drinking Water and Toxic Enforcement Act. This
act requires the governor of California to publish a list of sub-
stances known to the state to cause cancer, birth defects or
other reproductive
harm and requires businesses to warn cus-
tomers of potential exposure to such substances. Gas appliances
can cause minor exposure to four of these substances, namely
benzene, carbon monoxide, formaldehyde
and soot, caused pri-
marily by the incomplete combustion of natural gas or LP fuels.
Properly adjusted dryers will minimize incomplete combustion.
Materials
You Will
Need
4"
Dia. Metal
Duct
(Recommended)
%
4"
Diam.
Metal
Elbow
Exhaust
Hood
Pipe Compound
4" Dia. Flexible
Metal
(Semi-Rigid)
UL Listed Transition
Duct
(If Needed)
4"
Duct Clamps
(2)
Kit WX08X10077
(Includes
2 Elbows)
or
4" Spring
Clamps
(2)
4"
Dia. Flexible
Metal
(Foil Type)
UL Listed Transition
Duct
(If Needed)
(5
4" Cover
Plate (If Needed)
Soap
Solution
For
(Kit WE1M454)
Leak Detection
Duct
Tape
Gloves
Flexible
Gas Line Connector
Safety
Glasses
Parts Supplied
2 Washer Hoses
%
2 Rubber
Washers
(washersmay be
in water hoses)
oo
2 Stainer Screens/
Ruber
Washers
1 Cable
Tie
19

Advertisement