Settings Affected by INIT, SAVE, and LOAD
Commands
The following commands apply to camera setting data.
Command
AE-MODE
INIT initializes to fixed value.
AGCMAX-STEP
INIT initializes to fixed value.
AGCMAX-FINE
INIT initializes to fixed value.
CCDIRIS-MAX
INIT initializes to fixed value.
SSHUTTER-MAX
INIT initializes to fixed value.
AE-SPEED
INIT initializes to fixed value.
AE-REF
INIT initializes to fixed value.
GAIN-STEP
INIT initializes to fixed value.
GAIN-FINE
INIT initializes to fixed value.
SHUTTER
INIT initializes to fixed value.
WB-MODE
INIT initializes to fixed value.
RGAIN
INIT initializes to factory default value.
BGAIN
INIT initializes to factory default value.
ATW-SPEED
INIT initializes to fixed value.
CRS-MODE
INIT initializes to fixed value.
DTL-MODE
INIT initializes to fixed value.
DTL-ENHANCER
INIT initializes to fixed value.
2DNR-MODE
INIT initializes to fixed value.
3DNR-MODE
INIT initializes to fixed value.
PEDESTAL
INIT initializes to fixed value.
GAMMA-MODE
INIT initializes to fixed value.
NEGAPOSI
INIT initializes to fixed value.
WHITECLIP
INIT initializes to fixed value.
WPC-MODE
INIT initializes to fixed value.
OPD-DISP
INIT initializes to fixed value.
OPD-AE-POS
INIT initializes to fixed value.
OPD-AE-SIZE
INIT initializes to fixed value.
OPD-AWB-POS
INIT initializes to fixed value.
OPD-AWB-SIZE
INIT initializes to fixed value.
VOUTSEL
INIT initializes to fixed value.
HPHASE
INIT initializes to factory default value.
VPHASE
INIT initializes to factory default value.
COLORBAR
INIT initializes to fixed value.
FLIP
INIT initializes to fixed value.
OSD
INIT initializes to fixed value.
MEMO-DISPLAY
INIT initializes to fixed value.
Remarks
Setting Value Initialization
Command
INIT
Name
Parameter
None
Conditions
None
Process
Returns the camera's user memory to its
factory default state.
The last loaded user memory is not changed.
Remarks
The communication speed is not initialized.
Setting Value Saving
Command
SAVE
Name
Parameter 1 User memory save destination: 0 to 1
0: User memory A
1: User memory B
Conditions
None
Process
Writes to user memory A or B.
Setting Value Loading
Command
LOAD
Name
Parameter 1 Load original user memory: 0 to 2
0: User memory A
1: User memory B
2: Stand-alone user memory
Conditions
None
Process
Loads user's camera control command
settings, and saves them as the last loaded
user memory selection information. These
user memory settings are loaded the next
time the camera is turned on.
View Setting Values
Command
RMEM
Name
Parameter
None
Conditions
None
Process
Sends all data that can be set with camera
information.
The setting value of each camera control
command is displayed one command per