HSU-18/24HEK13/R2 Table of Contents 1.Features...................... 1 2.Introduction ....................2 3.Specifications ..................... 7 4.Printed circuit board connector wiring diagram ........9 5.Functions and control ................10 5.1 Main functions and control specification ..........10 5.2 Value of thermistor ................... 15 6. System configuration ................23 6.1 System configuration ................
HSU-18 24 HEK13/R2 Features 1. Features Intelligent air With twin-blade technology ,the airflow can be adjusted not to blow directly to human ESF filter : Trap harmful dust and remove unpleasant odors effectively DRY function: Make dehumidifying in the room when the unit is working in the "DRY" mode Anti-mold filter: Catches most small particles and remove unpleasant odors effectively Sleep mode: The setting temprature and the indoor noise can be adjusted to a more comfortable level when you set the "sleep mode"during night sleep...
Introduction HSU-18 24HEK13/R2 2. Introduction 2.1 Safety Cautions Be sure to read the following safety cautions before conducting repair work. The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead to serious accidents under some conditions if they are not followed.
HSU-18 24HEK13/R2 Introduction Warning Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock.
Page 6
HSU-18 24HEK13/R2 Introduction Warning Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to the electrical equipment, the internal wiring regulations and the instruction manual for installation when conducting electrical work. Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire. Be sure to use the specified cable to connect between the indoor and outdoor units.
Page 7
Introduction HSU-18 24HEK13/R2 Warning Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock.
Introduction HSU-18 24HEK13/R2 2.1.4 Using Icons Icons are used to attract the attention of the reader to specific information. The meaning of each icon is described in the table below: 2.1.5 Using Icons List Icon Type of Information Description A “note” provides information that is not indispensable, but may Note: Note nevertheless be valuable to the reader, such as tips and tricks.
r i ng Diagram Connector W HSU-18 24 HEK13/R2 4.Printed Circuit Board Connector Wiring Diagram 4.1 Indoor unit Connectors Indoor PCB 1)CN1connector for transformer input 3)CN3 connector for transformer output 2)CN2 connector for terminal block 4)CN5” or CN5”(1) connector for up and down step motor 5)CN6 connector for ambient temp. sensor and piping temp 6)CN7 connector for receiver display 7)CN8 connector for AC fan feedback motor 8)CN9 connector for AC fan motor CN5”...
Functions and Control HSU-18 24 HEK13/R2 5 Functions and control 5.1 main functions and control specifications Including brief introduction to air conditioners of series models and electric control function. 5.1.1 Automatic running 5.1.1.1 Single cold automatic run mode: After entering into this mode, the main control “MCU” determines the corresponding work pattern according to the indoor temperature so as to maintain the preset temperature (the preset temperature is 26 ).
Page 16
Functions and Control HSU-18 24HEK13/R2 5.1.6 Timer function: You can set 24-hour timer on or timer off as required, and the minum time unit is 1 minute. After setting, the indicator of indoor unit is on , and it is off when timer setting is completed. There are several timer mode as follows.
HSU-18 24HEK13/R2 Functions and Control 5.1.8.4 Enter emergency operation from timer mode, then timer is cancelled. 5.1.9 Test run: 5.1.9.1 The temperature sensor of inlet air doesn’t work, and compressor starts (but subject to the limit of -minute delay excluding the first time), and high wind, cooling, and air door is open.The indoor fan motor runs, running indicator lights up, compressor relay and the one of outdoor fan motor is closed 5.1.9.2 During test run: The prevention of freezing of evaporator doesn’t work.
HSU-18 24HEK13/R2 System Configuration 6. System Configuration 6.1 System Configuration After the installation and test operation of the room air conditioner have been completed, it should be operated and handled as described below. Every user would like to know the correct method of operation of the room air conditioner, to check if it is capable of cooling (or heating) well, and to know a clever method of using it.In order to meet this expectation of the users, giving sufficient explanations taking enough time can be said to reduce about 80% of the requests for servicing.
HSU-18 24HEK13/R2 System Configuration Operation Emergency operation and test operation Base Operation Emergency Operation: Use this operation only when the remote controller Remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which SPEED means the start of this operation.
HSU-18 24HEK13/R2 System Configuration Operation Sleep Operation In AUTO mode The unit operaters in corresponding sleep mode Before going to bed,you can simply press the SLEEP adapted to the automatically selected operation button and unit will operate in SLEEP mode and bring mode.
HSU-18 24HEK13/R2 System Configuration Operation Timer On/Off On-Off Operation For Smart Use of The Air Conditioner Set clock correctly before starting TIMER operation. Do not block the air inlet Setting of proper room 1.After unit starts, select your desired operation mode. temperature or outlet 2.Press TIMER button to change TIMER mode.
Page 30
HSU-18 24HEK13/R2 System Configuration Maintenance Replacement of Air Purifying Filter (NOTE: Air purifying filter is optional part) ATTENTION: 1.Open the lnlet Grille The white side of the photocatalyst air purifying Prop up the inlet grille by using a filter face outside,and the black side face the unit. small device named grille-support which located in the right side of The green side of the bacteria-killing medium air...
Page 31
HSU-18 24HEK13/R2 System Configuration Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING Check proper When abnormality such as burnt-small found, Use an exclusive immediately stop the operation button and power source...
System Configuration HSU-18 24HEK13/R2 Trouble shooting Cautions Before asking for service, check the following first. The machine is adaptive in following situation Cause or check points Phenomenon 1.Applicable ambient temperature range: When unit is stopped, it won't restart The system does not restart immediately until 3 minutes have For: T1 immediately.
HSU-18 24HEK13/R2 Functions and control 7.Codes and Description 7.1.Problem Symptoms and Measures Symptom Check Item Details of Measure Check to make sure that the rated voltage is None of the units Check the power supply. supplied. operates Check the indoor PCB Check to make sure that the indoor PCB is broken Equipment operates but does...
HSU- HEK13/R2 Codes and description 7.2 Error Codes and Description indoor display Code indication Reference Description Page indoor Room temperature sensor failure Indoor Malfunction u l i The code indication that is listed above is the main fault Troubleshooting Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred.
HSU-18 24HEK13/R2 Installations 9. Installations Preparation Selection of Installation Place Necessary Tools for Installation Torque wrench Indoor Unit Driver (17mm,22mm,26mm) Nipper Place, robust not causing vibration, where the body can be supported suf ciently. Hacksaw Pipe cutter Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the Hole core drill Flaring tool unit are not disturbed.
HSU-18 24HEK13/R2 Installations Installation of the Indoor Unit Drawing of pipe [ Rear piping ] Floor fixing dimensions Floor fixing dimensions Draw pipes and the drain hose, then fasten them with the adhesive tape of the outdoor unit of the outdoor unit (Unit:mm) (Unit:mm) [ Left Left-rear piping ]...
HSU-18 24HEK13/R2 Installations Outdoor unit Installation of Outdoor Unit Power cable: 3G1.0mm Drawing for the installation of indoor and outdoor units Install according to 3G1.0mm Connection of pipes Indoor unit Outdoor unit HSU-07HEK13/R2 To bend a pipe, give the roundness as large as possible not to crush the pipe , and the bending radius should be 30 to 40 mm or longer.
Page 48
Installations No gas leakage? On Drainage In case of gas leakage, tighten parts of pipe connection. If Please install the drain hose so as to be downward slope without fail. leakage stops, then proceed 6. steps Please don’t do the drainage as shown below. If it does not stop gas leakage, discharge whole refrigerants from the service port.
Page 49
Piping diagrams Domestic air conditioner...
HSU-18 24HEK13/R2 Outdoor OUTDOOR DIAGRAM 0010560078 TO INDOOR UNIT 1(L) 2(N) FRESH AIR MOTOR W(orBorBR) CAPACITOR CAPACITOR 4-way valve TO INDOOR COMPRESSOR FRESH AIR MOTOR FAN MOTOR NOTE: BL:BLUE 1.See above for wiring of heat pump type. 2.There are no dotted lines on cool only type.(marked BLACK with @),Wire is connected from 4 (marked with @@)on terminal block to 1.
HSU-18 24HEK13/R2 Operation range 10.6 Operation range Cooling 40 43 l l u indoor temp Notes The graphs are based on the following condition Equivalent piping length 7.5m Level difference Domestic air conditioner...
Page 58
HSU-18 24HEK13/R2 10.7 Accessories HSU-18/24HEK13/R2 R-03 dry battery Steel nail Plastic cap Cover Cushion Pipe supporting plate Drain-elbow...
Page 59
Heating Nominal cooling capacity (12000BTU/h) The structure code of indoor & outdoor unit: S(wall-mounted) H-Abbreviation of Haier Examples: HSU-07RD03/R1,It represents wall-mounted split type heat pump air conditioner .The cooling capacity is 7000BTU/h,and the power supply is 220-230V/50Hz,”D” means the developing sequence,and"R1"...
Page 60
The end HSU-18 24HEK13/R2 Liu Ming Zhang Jing He Shiquan Wu Hongjin 0532 8893 6935...