The Oximeter 1. Power of batteries might be
can not be
inadequate or not be there at all
powered on
2. Batteries might be installed
incorrectly
3. The Odrneter mig)) be damaged
Indication
1. The product is automatically
lamps are
powered off when no signal is
suddenly off
detected longer than 8 seconds
2 Power quantity of the batteries is
started being inadequate
Error3' or
1. Low power
"Error4" is
2. Receiving tube being shielded or
displayed on
damaged together with broken
screen
connector.
3. Mechanical Misplace for
receive-emission tube
4. Amp circuit malfunctions.
Error7' is
1. Low power
displayed on
2. Emission tube damaged.
screen
3. Current control circuit
malfunctions.
1. Please replace batteries
2. Please reinstall the batteries
3. Please contact with local
customer service centre
1. Normal
2. Replace the batteries
1. Change batteries
2. Please contact local customer
service center
3. Please contact local Customer
service center
4 Please contact local
customer service center
1 Please change battery
2 Please contact local
customer service center
3 Please contact local
customer service center
1.
Replace the batteries in time when low voltage lamp is lighted.
2.
Clean surface of the fingertip oximeter before it is used in diagnosis for patients.
3.
Remove the batteries inside the battery cassette if the Oximeter will not be
operated for a long time.
4.
It is best to preserve the product in a place where ambient temperatures is -20
t-55t(4---131I') and relative humidity is n93%.
5.
It is recommended that the product should be kept in a dry environment anytime.
A wet ambient might affect its lifetime and even might damage the product.
6.
Please follow the law of the local government to deal with used battery
1. Display Type: LED
2. Sp02
:
Measurement range: 70-99%
Accuracy. 80%-99%. ±20 %; 70%-80%±3%; ..69% no definition.
3. Pulse Rate:
Measure range: 30-235 BPM
Accuracy: 30-99bpm, ±2bpm; 100-235bpm, ±2%
Pulse Intensity: Bargraph Indicator
4. Power Requirements:
Two AA) alkaline Batteries
Power consumption: Less than 40mA
Low power indication:
LIZIP
Battery Life. Two AAA 1.5V, 600mAh alkaline batteries could be continuously operated
as long as 30 hours.
5. Dimension:
Length: 56mm - 62mm
Width: 32mm---38mm
Height: 34mm-38mm
Weight: 45g 60g (including two AAA batteries)
6. Environment Requirements:
Operation Temperature: 5---40C
Storage Temperature: -20-- 55%
Ambient Humidity:
80%, no condensation in operation.
93%, no condensation in storage
7. Measurement Performance in Low Perfusion Condition: required the test
equpment (B(O-TEK INDEX Pulse Oximeter tester) the pulse wave is available without
failure when the simulation pulse wave amplitude is at 6%.
8. Interference Resistance Capacity against Ambient Light: Device works normally
when mixed noise produced by BlO-TEK INDEX Pulse Oximeter tester.
Symbol
Definition
Type BF applied part.
Attention, consult accompanying documents.
% Sp02
Oxygen saturation
BPM
Heart rate (BPM)
IIZII
Low power indication
No Sp02 Alarm
Power switch
SN
Serial No.
Applicable m
MD300C1
MD300C1C MD300C12 MD300C12-P MD300013 MD300014
MD300C1-E MD300C15 MD300C16 MD300C17 MD300C18 MD300C19
MD300C10 MD300C1A MD300C16 MD300C1D MD300C1E
Note: The illustration used in this manual may differ slightly from the appearance
of the actual product.
EMC of this product complies with 1EC60601-1-2 standard
The materials which the user can come into contact have no toxicity and no action on
tissues comply with 15010993-1, 1S010993-5 and lSO10993-10.
Guidance and manufacturer's declaration - electromagnetic emission
The
Pulse Ox/meter
is intended for use in the electromagnetic environment specified
below. The customer or the user of the
Pulse Oximeter
should assure that it is used
in such an environment.
Emission test
Compliance
Electromagnetic environment - guidance
RF emissions
Group 1
The
Pulse Oximeter
uses RE energy only for its
CISPR 11
internal function. Therefore, its RF emissions are
very low and are not likely to cause any
interference in nearby electronic equipment.
RF emission
Class B
The
Pulse Ox/meter
is suitable for use in all
CISPR 11
establishments, including domestic
establishments and those directly connected to
the public low-voltage power supply. network
that supplies buildings used for domestic
purposes.
Possible
Problems
,t-ii and I7rTTh..
Possible reason
Solution
Sp02 or PR
1. Finger is not inserted correctly
1 .Retry by inserting the finger
can not be
2. Patient's Oxyhemoglobin value is 2. Try some more times, If you
shown
too low to be measured
can make sure no problem is
normally
existing in the product.
Please go to a hospital timely
for exact diagnosis.
Sp02 or PR is 1. Finger might not be inserted deep 1. Retry by inserting the finger
shown
enough.
2. Try not to move
unstably
2. Finger is trembling or patient's
body is in movement status.
S
Be,
iing Choice Eiecfron,c Technoiogy Co. Lid
Blcngycan81127-1128.Fcei'g R.A36
100039 hepng
PEOPLE'S REPUBLIC Of CHINA
Em-t-13. 80,20537
EC REP
Ho,nbcrg GERMANY
Shanghai internatIonal
Raiding Coip.Gnlb$-4(Edrop,.)
'
ALL RIGHTS RESERVED
Issue date: 25/February 2010

Advertisement

loading
Need help?

Need help?

Do you have a question about the Fingertip Pulse Oximeter and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Md300c1