FT Status LED
The LED stays green while the server is running normally in DUPLEX mode. If this LED does not
illuminate or illuminates/blinks in amber, there is something wrong with the server.
The table below shows indications of the FT Status LED and their meanings.
FT status LED
Description
indications
Green
The device is running
successfully in the Duplex
mode.
Not on
Power is off
Performing POST.
The device is running in
the Sipmlex mode
Amber
One of the CPU/IO
modules has a problem.
Memory dump is being
Blinking in
amber
performed.
General Description 2-23
Action
–
–
Wait for a while; it will illuminate in green and the
mode will become Duplex shortly after POST.
The LED indicates only one of modules is
running. If this status is observed right after the
system startup or activation of a module that has
been stopped, wait for a while. The status will
change to the Duplex mode with the LED lit in
green.
If the LED does not illuminate in green after a few
minutes, a device (LAN, FC-connected storage,
or internal disk) that should be redundant may not
be attached properly. Check to see devices to
make sure they achieve redundancy.
Check the CPU/IO module status LEDs to find the
failing module, and then report your sales agent
which LED of the failing module is blinking.
Wait for memory dump to be completed.