Line or low voltage humidistat/dehumidistat

Advertisement

Available languages

Available languages

Quick Links

Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
These wall-mounted, line or low voltage humidity controls
are available as a Humidistat commonly used to control
and operate a furnace humidifier or as a Dehumidistat
commonly used to cycle an air conditioning system to
control humidity in an unoccupied home to prevent mil-
dew build-up associated with high humidity levels.
These humidity controls feature a moisture-sensitive
nylon sensing element and also provide positive ON-OFF
settings for manual operation.
If in doubt about whether your wiring is line, or low voltage,
have it inspected by a qualified heating and air condition-
ing contractor, electrician, or someone familiar with basic
electricity and wiring.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
CONTENTS
Description .............................................................................. 1
Precautions ............................................................................. 1
Specifications .......................................................................... 2
Installation ............................................................................... 2
Select Humidity Control Location
Route Wires to Location
Wiring
Attach Humidity Control to Wall
Operation ................................................................................ 4
Humidistat Control
Dehumidistat Control

INSTALLATION INSTRUCTIONS

2271W
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system, at main
fuse or circuit breaker box, until installation is
complete.
Do not short out terminals on primary control to
test. Short or incorrect wiring will burn out humid-
ity control and could cause personal injury and/or
property damage.
Do not use on circuits exceeding the rated volt-
age. Higher voltage will damage control and could
cause shock or fire hazard.
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
2271/72/73/74W
Line or Low Voltage
Humidistat / Dehumidistat
DESCRIPTION
PRECAUTIONS
CAUTION
WARNING
PART NO. 37-9600D
2274W
Replaces 37-9600C
0528

Advertisement

loading

Summary of Contents for White Rodgers 2274W

  • Page 1: Installation Instructions

    These humidity controls feature a moisture-sensitive nylon sensing element and also provide positive ON-OFF settings for manual operation. 2271W 2274W PRECAUTIONS If in doubt about whether your wiring is line, or low voltage, This control is a precision instrument, and should be have it inspected by a qualified heating and air condition- handled carefully.
  • Page 2: Specifications

    5% RH 2272W Operating Ambient: 10 to 40 C (50 to 104 F) 2273W De-Humidistat 1.0A, @ 120V AC, 60 Hz. 2274W Pilot Duty 30V AC, 60Hz., 60VA. INSTALLATION SELECT THERMOSTAT LOCATION 2. Through this hole drop a light chain, or 6" chain Proper location insures that the humidity control will attached to a strong cord.
  • Page 3 ATTACHING HUMIDITY CONTROL TO ELECTRICAL BOX 1. With wallplate still attached to humidity control and wires through wallplate, connect leads together; one black to Line, other black to Load and secure with wire nuts. Connect green wire to electrical box ground. Figure 2.
  • Page 4 Figure 5. Typical Parallel Wiring Diagram of Dehumidistat with THERMOSTAT COOL 1E56/1F56(W) Heat/Cool Low Voltage Thermostat SWITCH FIXED COOLING HEAT ANTIC. BIMETAL ADJ. HEATING ANTIC. TYPE 1E56/1F56(W) THERMOSTAT THERMOSTAT CAPTIVE TYPE 2273/2274 SCREWS DEHUMIDISTAT SWITCH SUBBASE AUTO SYSTEM SWITCH GREEN WIRE WIRE SYSTEM NUTS...
  • Page 5 SETTING & ADJUSTMENT DEHUMIDISTAT CONTROL A dehumidistat wired in parallel may be used to maintain 1. A relative humidity environment of 50-55% is desir- the relative humidity level during unoccupied times re- able during the summer. To achive this the cooling gardless of ambient temperature.
  • Page 6 Ces humidostats sont dotés d'un détecteur de nylon et d'un bouton avec positions ON et OFF pour le 2271W fonctionnement manuel. 2274W PRÉCAUTIONS Si vous n’êtes pas certain de la tension du câblage de Cette commande est un instrument de précision qui doit votre système (soit à...
  • Page 7 0,5 A à 120 V c.a., 60Hz. Plage de températures 2273W Humidostat de déshumidification: 2274W 1,0 A à 120 V c.a., 60 Hz de fonctionnement : 10 à 40 C (50 à 104 F) Charge de veilleuse : 30V c.a., 60Hz., 60VA.
  • Page 8 MONTAGE DE LA COMMANDE DANS LA BOÎTE DE RACCORDEMENT 1. Pendant que la commande est encore montée sur le socle, par lequel passent les fils, exécutez ainsi les raccordements:un fil noir sur le secteur, l'autre sur la charge, en prenant soin de les relier à l'aide de Figure 2.
  • Page 9 Figure 5. Schéma typique de câblage de la commande de COMMUTATEUR déshumidification en parallèle avec un thermostat de chauffage et DU THERMOSTAT CLIMATISATION ANTIC. de climatisation à basse tension 1E56/1F56(W) CLIM. CHAUFFAGE FIXE BILAME ANTIC. CHAUF. RÉGL.. THERMOSTAT 1E56/1F56(W) THERMOSTAT COMMANDE DE PRISONNIÈRES COMM.
  • Page 10 RÉGLAGE Température °C Supérieure 0° à l'exterérieur °F Supérieure 1. Un taux d'humidité relative de 50 à 55% est désirable +20° pendant l'été. Pour obtenir ce taux, régler le thermostat Réglage de climatisation à un point de consigne supérieur à la 25 % 30 % 35 %...

This manual is also suitable for:

2273w2272w2271w2271