The condensate in the pump can be harmful if it comes Potentially dangerous situations for the prod- into contact with the eyes. Make sure the ecoLEVEL con- uct and environment! densate pump is operated out of the reach of children.
Vaillant warranty General information We only grant a Vaillant manufacturers warranty if a The ecoLEVEL condensate pump is used for the extrac- suitably qualified engineer has installed the system in tion of condensate which accumulates in condensing accordance with Vaillant instructions. The system owner boilers.
1. The appliance must be installed in accordance with CE label safety regulations, as well as all other relevant local or CE labelling shows that the ecoLEVEL condensate pump state regulations. Proper grounding, adequate electri- complies with the requirements of the following applica-...
Vaillant warranty observe all danger and caution warnings. We only grant a Vaillant manufacturers warranty if a 6. This list is not a comprehensive representation of all suitably qualified engineer has installed the system in the required measures for the safe operation of the accordance with Vaillant instructions.
Fig. 4.1 Dimensions and installation spaces suitable wall is not available, a suitable mounting surface must be prepared. The ecoLEVEL condensate pump should not be used as Installing the wall bracket a storage shelf. • Slide the pre-assembled wall bracket downward and out of the condensate pump housing.
• Pull off the cover and return valve by lifting them upwards. Fig. 4.2 Installing the wall bracket Fig. 5.1 Removing the return valve and cover • Push the feed hose into one of the feed openings (3) on the removed cover until it catches. Installation and maintenance manual ecoLEVEL...
(4) and con- nect the additional hose as shown above. ca 3˚ • Put the cover back onto the ecoLEVEL condensate pump from above. Connecting and laying the discharge hose • Push the discharge hose onto the removed non-return valve as far as it will go.
• You can install a mains plug on the cable (1) and con- the cable (1) with the free end. nect the pump with a mains socket (the plug is not The overflow safety switch is connected to the Vaillant included in the scope of delivery). boiler using the cable (2).
Page 14
• Remove the cable bridge from the blue slot (“Anl- Therm”) on the circuit board. • Plug the blue Pro E plug on the end of the ecoLEVEL condensate cable into this slot. Fig. 6.2 Connecting the overflow safety switch, connection...
Page 15
• Connect with the mains voltage connection on the tions. boiler as shown in Fig. 6.4. • Connect to the 230 V mains voltage connection on the ecoLEVEL condensate pump as shown in Sec. 6.2. Boiler 230 V ~ 230 V ~ Fig.
7 Start-up 8 Maintenance 9 Troubleshooting Start-up Troubleshooting Once the ecoLEVEL condensate pump has been Problems mechanically and electrically installed, it is ready for The ecoLEVEL condensate pump can rectify temporary operation. The green LED lights up. faults during normal operation by itself. The red LED sig-...
Technical data 11 10 Customer service Vaillant customer service To ensure regular servicing, it is strongly recommended that arrangements are made for a Maintenance Agreement. Please contact Vaillant Service Solutions (0870 6060 777) for further details. Technical data Technical data Units...