The domestic hot water can only be adjusted on the throughout the boilers entire instruction pack. boiler if it is installed with a Vaillant uniSTOR unvented We assume no liability for any damage caused by cylinder and relevant controls. Once the controls are set the boiler operates automatically.
The boiler is supplied factory set for use on Natural • Do not use naked flames, such as matches or Gas (G20). The ecoTEC plus boilers can be field cigarette lighters. adjusted for use on LPG (propane G31), see section •...
If you have a sealed water system contact your in the countries of destination. installation/ servicing company as draining, refilling To obtain service, please call your installer or Vaillant and pressurising MUST be carried out by a competent Service Solutions (0870 6060 777).
It is important that no alteration is made to the boiler, Appliance Gas council numbers without permission, in writing, from Vaillant. ecoTEC plus 415 41-044-53 Any alteration that is not approved by Vaillant, could ecoTEC plus 418 41-044-54 invalidate the warranty and could also infringe the ecoTEC plus 428 41-044-55 current issue of the Statutory Requirements.
125 mAT 125 mAT 125 mAT Minimum flow rate of water L/min. 10.8 12.9 20.3 27.2 through the boiler Weight Electrical supply 230/~50 230/~50 230/~50 230/~50 External fuse Power input Case height Case width Case depth Installation and Servicing ecoTEC plus...
Preliminary remarks for room sealed spanners (not pipe wrench, or extensions, etc.). appliances Incorrect use and/or unsuitable tools can lead This appliance should only be installed with a Vaillant to damage being caused (e.g. gas or water flue system. leakage)! Install the flue system as detailed in the separate flue installation instructions supplied with this boiler.
(15 mm). The complete installation must be checked for leaks and purged as described in BS 6891. Danger! Vaillant appliances are certified only for use with genuine Vaillant flue pipes. Only use genuine Vaillant flue pipes. Malfunctions can occur if you use other accessories.
Vertically from a terminal on the same wall 1500 for cooling purposes. Horizontally from a terminal on the same wall Distance from adjacent wall for vertical Flue Table 3.1 Flue terminal position for a fan assisted concentric flue Installation and Servicing ecoTEC plus...
Unvented hot water cylinder 3.14 Pump specification The ecoTEC plus can be connected to an unvented The pump should be fitted on the flow pipe from the hot water cylinder. Vaillant offer a range of cylinders boiler and have isolating valves each side.
Page 14
3 General requirements ecoTEC plus 415 pressure loss graph ecoTEC plus 428 pressure loss graph ecoTEC plus 418 pressure loss graph ecoTEC plus 438 pressure loss graph Fig. 3.8 Pressure loss Installation and Servicing ecoTEC plus...
The cold feed must be 15mm minimum size. The vent must rise continuously and be unrestricted. It is important that the relative positions of the pump, cold feed and open vent are as shown in fig 3.9. Fig. 3.9 Open vented system Installation and Servicing ecoTEC plus...
BS5449 and filling loop. BS7074 Part 1. Example: For an initial design pressure of 0.7 bar, the minimum total vessel volume required is 0.063 x Total System Volume. Fig. 3.10 Typical installation Installation and Servicing ecoTEC plus...
Institute of Gas Engineers document IGE/UP/7/1998. If in doubt seek advice from the local gas undertaking or Vaillant. A removable compartment door can be placed at least 5mm in front of the appliance...
4 Boiler installation sequence 4.1.4 Contents included with delivery The Vaillant ecoTEC plus is delivered pre-mounted in a package unit. Check that all the parts have been delivered intact (see fig. 4.2 and table 4.1. DO NOT remove the boiler from the polystyrene base at this stage.
Remove the front casing securing screws then lift the RETAINING case upwards off the two top retaining dowels, see fig DOWEL (2 OFF) 4.4. Note! Take care not to damage the front casing. FRONT CASING SCREW (2 OFF) Fig. 4.4 Removing front casing Installation and Servicing ecoTEC plus...
The condense drain is suitable for use with standard "Push fit" overflow pipe and couplings DO NOT use adhesive when connecting to the spigot (1) The condense drain pipe (2) should be non corrosive plastic. The drain pipe should have a continuous fall Installation and Servicing ecoTEC plus...
Ensure that the power supply is connected such that the current carrying conductors become taut before the earth conductor should the supply cable slip from the cable clamp Fig. 4.6 Water connections Installation and Servicing ecoTEC plus...
Page 24
X 20/17 red (24 Vdc) X 20/18 red (24 Vdc) X 20/9 blue (earth) green/yellow Chassis earth Pump connection fuse T2E 250 Volts 230V black green/yellow green/yellow Electronic control box Fig. 4.10 Mains Supply Connection Installation and Servicing ecoTEC plus...
34 mbar. Caution! Before operating the boiler check the type plate and ensure that the correct gas type Fig. 5.2 Gas service valve Installation and Servicing ecoTEC plus...
Adjust the control (1) anti-clockwise to its lowest Note! setting (The indent position just before off). If contacting Vaillant Service Solutions please Turn on external heat demand to boiler. remember to quote the fault code, as this will The fan should start and after a few seconds the help to pinpoint the fault.
CASE ON CASE OFF CASE ON THROTTLE ADJUSTMENT The ecoTEC plus is able to be field adjusted for use on ecoTEC LPG – propane G31 gas. To enable conversion the use plus 415 9.1+0.2-0.5 9.3+0.2-0.5 10.1+0.5-0.5 10.3+0.5-0.5 5 TURNS of a combustion analyser is necessary.
(see Section 7.1.1 Fig. 7.2 Display indicator during heating mode 7.1.1 Domestic hot water (If optional VR65, uniSTOR cylinder & Vaillant control are installed) • Switch on the appliance. • Fully open the hot water tap. • Press “i” to activate the status indicator.
7.1.3 Final flush of the heating system (hot) Vaillant warranty • Operate the appliance until the heating system is up Vaillant provide a full parts and labour warranty for to temperature. this appliance. • Check the heating system for leaks.
Note! Only genuine Vaillant spare parts may be used for The boiler is fitted with a combustion analysis inspections, maintenance and repair work to ensure test point. A suitable combustion analyser...
Page 32
If a flue gas analyser is not available check the ignition and burner flame picture visually. through the viewing window. Check boiler for leaks of any kind, rectify as necessary. Complete gas boiler commissioning checklist (Benchmark). Table 8.1 Inspection and maintenance steps Installation and Servicing ecoTEC plus...
3. Check the operational performance of the central heating agrees with the technical specification. INNER CASE CHASSIS PANEL SCREW (2 OFF) ELECTRONICS SCREW (4 OFF) Fig. 8.2 Control panel Installation and Servicing ecoTEC plus...
Inspect the burner for any signs of damage. Remove and discard the burner door seal and replace with new, see fig 8.7. Removal of the burner is not necessary during a normal service. Fig. 8.5 Gas service cock Installation and Servicing ecoTEC plus...
CONNECTOR ELECTRODE COMBUSTION CONNECTOR CHAMBER BURNER DOOR SECURING NUTS (5 OFF) IGNITION LEAD GAS VALVE CHASSIS FRONT ELECTRICAL RETAINING SLOTS LEAD GAS PIPE BRACKET GAS VALVE ELECTRICAL PLUG Fig. 8.6 Fan, Gas valve and Burner Installation and Servicing ecoTEC plus...
• Check for ignition and an even flame on the burner. • Check that the heating system is working. • Fill out the Benchmark gas boiler commissioning checklist at the rear of this guide. Installation and Servicing ecoTEC plus...
(if fitted) are fully open. 5. Set the central heating temperature to maximum. 6. Set the domestic hot water temperature to maximum (Only if additional Vaillant accessories are fitted). 7. Check that all external controls are on and calling for heat (if no external controls are fitted, boiler terminals 3 and 4 must be linked).
S.96 Return-sensor check is running, demand (DHW or with out having to enter the password again. heating) is blocked S.98 Flow-/Return-sensor check is running, demand (DHW or heating) is blocked Table 10.1 Status codes (continued) Installation and Servicing ecoTEC plus...
Page 40
°C d.44 Digitised ionisation potential Display range of 0 to 102, > 80 no flame, < 40 even flame d.47 Outside temperature (with weather compensating Vaillant Actual value in °C controller only) d.67 Remaining burner anti cycling time in min d.76...
Page 41
Adjustment range in min: 20, 21, 22 to 90 (Factory setting: 45) controller (system boilers only) d.77 Storage partial load (storage charging capacity Adjustment range in kW: appliance specific Factory setting: max limit, system boilers only) output Table 10.3 Diagnostics codes of the second diagnostic level Installation and Servicing ecoTEC plus...
Pump blocked or defective, pump output too low, flow and return NTC between flow and return NTC too large interchanged F.24 Water shortage, temperature rise too Pump blocked, insufficient pump output, air in appliance, water pressure too quick Table 10.4 Error codes Installation and Servicing ecoTEC plus...
Page 43
Condensate pump defective or flume flap feedback triggered heating F.78 Wrong configuration with accessory link box VR65 connected to combination boiler No communication to main board Connection error display main board Table 10.4 Error codes (continued) Installation and Servicing ecoTEC plus...
Remove the gas valve refer to section 11.3. Remove the venturi plate secured with three screws and remove the two screws securing the fan to the gas manifold, see fig 11.1. Check the gasket and replace if necessary. Installation and Servicing ecoTEC plus...
Parts replacement 11 Note! The ecoTEC plus 428 and 438 fan is secured through an extension piece with two securing screws, check and replace any seals or gaskets if necessary. 11.5 Replacing the heat exchanger For access refer to section 8.1.4.
12.1 Appliance ADAPTER The Vaillant ecoTEC plus consists largely (92 %) of metal components designed for eventual recycling by incorporation into the smelting process of a steelworks. This gives these parts virtually unlimited FLOAT scope for subsequent re-use.