Table of Contents Table of Contents ..................4 Preface......................6 Important notice..................6 Environmental information..............7 Safety Instructions................. 8 Recommendations for using your display system......11 Unpacking and handling tips .............. 12 Preventing fire and injury..............13 Cleaning the display................14 Shipping/storing the display ..............
Barco software products are the property of Barco. They are distributed under copyright by Barco N.V., for use only under the specific terms of a software license agreement between Barco N.V. and the licensee.
Environmental information Disposal Information The lamps inside the display contain mercury. Do not throw the display in the trash. Dispose of it as required by local ordinances or regulations. This equipment has required the extraction and use of natural resources for its production. It may contain hazardous substances for health and environment.
Safety Instructions General Recommendations • Read the safety and operating instructions before operating the display. • Retain safety and operating instructions for future reference. • Adhere to all warnings on the display and in the operating instructions manual. • Follow all instructions for operation and use. Electrical shock Warning- To prevent the risk of fire or shock hazards, do not expose...
Page 9
Mode of Operation: Continuous. Intended use This display is an AMLCD display designed for viewing medical X-ray images. This unit should not be used near patients and should be kept outside of 1.83 m perimeter and 2.29 m vertical. Power connection Power requirements: The display must be powered using a medical approved 12VDC power supply (MDRC-1119) or a 24VDC power supply (MDRC-2120).
Page 10
combinations – systems – shall comply with the standard IEC 60601-1-1, Safety requirements for medical electrical systems. Equipment not complying with UL/EN / IEC 60601-1 shall be kept outside the patient environment, as defined in the standard. Equipment not complying with IEC 60601 must be kept outside the patient environment, as defined in the standard as at least 1.5 meters from the patient or the patient support.
You can activate a screen saver in the “Display properties” window of your workstation. Barco recommends setting screen saver activation after 5 minutes of non-usage. A good screen saver displays moving content. In case you are working with the same image or an application with...
To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels. To learn more about LCD technology and missing pixels, consult the dedicated white paper available at www.barcomedical.com. 4. Enhance user comfort Every Barco multi-head display system is color matched with the highest specification in the market.
Cosmetics and oils on the skin are both detrimental to the screen and difficult to remove. • Allow the display to warm up to room temperature before turning it on. Avoid sudden temperature changes in the environment, as this may cause condensation, which damages the display.
Cleaning the display Observe the following guidelines to maintain display and LCD screen. • Use a clean, lint-free, absorbent cotton cloth to clear off any residual glue from removal of the protective film or to remove surface dust. Apply light pressure to remove the dust. •...
3 Use the stand lock to anchor the panel. Explanation of symbols DISPOSAL. Do not use household or municipal waste collection services for disposal of electrical and electronic equipment. EU countries require the use of separate recycling collection services. CAUTION. Read the accompanying text carefully for proper operation and maintenance of the display system.
Introduction About the product Thank you for choosing Barco. The MDRC series are LCD displays with an active matrix, thin-film transistor (TFT) liquid crystal display (LCD). These products also demonstrate the following outstanding features: MDRC-1119 • Dual Analog and Digital signal.
Page 17
MDRC-2120 • Dual Analog and Digital signal. • 20.1” diagonal Screen. • 1600x1200 high resolution. • Wide Viewing Angle Technology. • 31.5 ~ 93.75 kHz horizontal scan. • 59 ~ 61 Hz refresh rate. • Auto Adjustment and Re-scaling function. •...
Tilt Grasp the LCD Display with both hands and adjust the tilt as desired. Kensington Security Slot The Monitor can be secured to your desk or any other fixed object with Kensington lock security products. Kensington lock is not included. Kensington Security Slot...
Start Your Installation Connecting the Display Use only the power adapter, power cord, and the video cable shipped with this display. For MDRC-1119 :The universal external 12V DC/ 5.0A power adapter (100-240V~, 1.5A, 50-60Hz for power adapter rating) is the AULT (JMW160KB1200F04). For MDRC-2120, the universal external 24V DC/ 2.7A power adapter (100-240V~, 1.5A, 50-60Hz for power adapter rating) is the AULT (JMW160KA2400F04) To setup this display, please refer to the following figure and...
Adjusting the screen position Vertical Height Portrait/Landscape Left to Right Pan Front to Back Tilt Remove Monitor Stand may forcefully extend and cause injury Lift Monitor to "Full UP" position in advance Picking up the base or removing the monitor...
No./ Icon Control Function - Power Switch 1. Press the jog dial button for 1 sec to - Menu power off to the LCD Display. Jog Dial button 2. Swivel jog dial button for OSD menu 1. Green indicates the display is turned on.
Adjustments Menu Function Description Brightness To adjust the overall image and background Brightness level. Contrast* To adjust the image brightness in relation to the background (only applicable if VGA is selected) Sharpness* Manual adjustment of the image sharpness (only applicable if VGA is selected) Gamma Gamma selection Native...
Page 29
Dynamic Gamma Dynamic Gamma 1.8 selection Dynamic Gamma Dynamic Gamma 2.2 selection Dicom Dicom selection User User definable table via QAWeb Agent Exit Exit Menu...
Color Menu Function Description Native Set the image color temperature to the LCD panel’s native, uncorrected color temperature Clearbase Set the image color temperature to Clearbase Bluebase Set the image color temperature to Bluebase User User definable color temperature. Can be changed manually Exit Exit to main menu...
Geometry Menu Function Description Auto set* Automatically adjusts the image parameters to obtain a correctly aligned image clock* Manually adjust the internal clock frequency. Increasing this value makes the image wider. Decreasing this value makes the image Smaller. Phase* Manually adjusts the internal clock phase. When not adjusted correctly, vertical bands with alternate intensity appear in the image.
Setting Menu Function Description OSD setting OSD settings menu Factory init Select this function to reset all display parameters to the factory settings Language Select the OSD language DPMS DPMS menu Exit Exit menu...
Page 33
OSD Settings Menu Function Description OSD Time out Set time when OSD will disappear OSD Horizontal OSD horizontal alignment OSD Vertical OSD vertical alignment OSD direction Rotate OSD to Landscape or portrait Exit Exit menu...
Information Menu Function Description Display Name MDRC- 1119 or MDRC-2120 Firmware version Firmware version Display run time Display run time Backlight run time Backlight run time Notes:Symbol (*) means only analog signal is used.
Appendix Troubleshooting If you are experiencing trouble with the LCD display, refer to the following troubleshooting. If the problem persists, please contact your local dealer or our service center. Problem: No image appears on screen. • Check that all the I/O and power connectors are correctly and well connected as described in the “Installation”...
Problem: Image is unstable and flickering • Use “Phase” to make an adjustment. Problem: Image is scrolling • Check and make sure the VGA signal cable (or adapter) is well connected. • Check and reconfigure the display mode of the vertical refresh rate of your graphics card to make it compatible with the LCD Display.
OSD languages English, French, German, Spanish, Italian, Dutch, Simplified Chinese, Traditional Chinese, Korean. Options Protective Cover Touch Screen Landscape/Portrait Approvals EN 60601-1-2; FCC-B; ICES-001, VCCI, KETI, CCC, BSMI Safety CE EN60601-1; UL 60601-1, c-UL, CCC, KETI, PSE, BSMI Mechanical characteristics Display dimensions (W x H x D) 418 x 346 x 70 mm Landscape, w/o pedestal...
Compatibility Modes MDRC -1119 Vertical Horizontal Standard Resolution Refresh Scan (Hz) (KHz) 640x350 31.5 IBM VGA IBM VGA 640x480 31.5 IBM VGA 720x400 31.5 640x480 37.9 VESA VGA VESA VGA 640x480 37.5 800x600 35.1 VESA SVGA VESA SVGA 37.9 800x600 VESA SVGA 48.1 800x600...
Page 42
Technical specifications MDRC-2120 LCD Panel MDRC-2120 Technology TFT Color LCD (IPS) Native resolution 1600 x1200 Active screen diagonal 20.1" (510.54 mm) Active screen area 432 x 331.5 mm Pixel Pitch 0.255 x 0.255 Visual Characteristic Maximum luminance 300 cd/m2 DICOM calibrated luminance 180 cd/m2 Image stabilization BLOS (Backlight sensor)
Page 43
OSD languages English, French, German, Spanish, Italian, Dutch, Simplified Chinese, Traditional Chinese, Korean. Options Protective Cover Touch Screen Landscape/Portrait Approvals EN 60601-1-2; FCC-B; ICES-001, VCCI, KETI, CCC, BSMI Safety CE EN60601-1; UL 60601-1, c-UL, CCC, KETI, PSE, BSMI Mechanical characteristics Display dimensions (W x H x D) 455 x 354 x 70 mm Landscape, w/o pedestal...
(EMC) laws. Barco NV has made great efforts to support the medical device industry, in particular, medical device manufacturers and medical device system integrators. We offer state-of-the-art color displays that are compliant...
Page 46
CE mark according to Annex XII of the directive, with no notified body annotation. In the opinion of Barco NV registration required to put this device into commerce is the responsibility of the medical device/system manufacturer, and Barco supports this requirement by providing a European Commission (EC) declaration of conformity.
Page 47
EU EMC Directive 89/336/EEC EU Electromagnetic Compatibility Directive EN 60601-1-2 (2001) Collateral standard electromagnetic Medical Electrical Equipment compatibility requirements EN 55011 (Class B) Limits and methods of measurements for radio interference characteristics of industrial, scientific, and medical equipment IEC 61000-3-2 Harmonic emissions IEC 61000-3-3 Voltage fluctuations/flicker...
Page 48
IEC 61000-4-6 Conducted immunity IEC 61000-4-8 Magnetic field immunity Conformance to the Medical Device Directive 93/42/EEC EN 60601-1 Medical Part 1 General requirements for safety Electrical Equipment. U.S. FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may...
Page 49
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technical for help. CAUTION: Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Page 50
Any claim under the Warranties must be notified to Barco in writing within 8 days from the date the defect or failure has been discovered or noticed the first time. The Customer, upon the occurrence of...
Page 51
Any host configuration not explicitly supported by Barco nv, MID. All software installed on the system, whether they are acquired from Barco nv, MID or third party. An exception is made for software delivered by Barco nv, MID that would prove to be a cause for the...
Page 52
(4): ‘Factory Calibrated Luminance’: is the typical luminance value that a specific diagnostic display model is calibrated at during the production process. This figure is printed on the Warranty certificate of each display or can be requested at your local Barco office. c. Lamps, optical components in projectors d.
Page 53
If there is an indication that the equipment was used – even temporary – outside its specifications, Barco nv, MID is entitled not to perform warranty repairs and terminate the warranty agreement. Any actions that have been taken by Barco nv, MID in this respect, may be invoiced to the Customer at normal pricing.
Page 54
NEGLIGENCE, STRICT TORT, WARRANTY OR OTHERWISE, SHALL BE LIMITED TO THE REPAIR OR REPLACEMENT OF THE PRODUCT OR ANY PART THEREOF WHICH SHALL BE AT CUSTOMER'S SOLE OPTION AND COST. BARCO’S LIABILITY SHALL NOT EXCEED THE PRICE OF THE ITEM OR ITEMS OF GOODS OR SERVICES UPON WHICH SUCH LIABILITY IS BASED.
Need help?
Do you have a question about the MDRC Series and is the answer not in the manual?
Questions and answers