Setting the internal switches
CAUTION:
These servicing instructions are for use by qualified service personnel only. To reduce the risk of fire
or electric shock do not perform any servicing other than that contained in the operating instructions
unless you are qualified to do so.
1
Remove the twelve screws, and take off the top
cover.
Top panel:
2 screws
Side panels: 5 screws each for the left and right
panels
Screws (k5)
2
Set the switches on the back side of the front
panel.
Select the method to be used to input the tally
signals.
MAKE:
The tally signals are input by a contact
connection.
POWER:
The tally signals are input by DC power.
MAKE (contact connection) is the factory setting.
For red tally signal
For green tally signal
POWER
MAKE
Screws (k2)
Screws (k5)
Select the microphone to be used for INCOM.
CM (carbon type) is the factory setting.
CM
Carbon type
DM
Dynamic type
11