Preparing for installation
Plume kit installation instructions
The plume kit enables the relocation of the flue outlet of a standard horizontal flue system
to another position and is available as an optional extra, please contact your supplier for
further information.
Routing options
A
Plume kit standard delivery 2m max
length
Ensure the max. length of 3m (externally)
and 7m (internally) is not exceeded.
The max. length is reduced by 1m when
using a further 87° bend or 2x45° bends.
32
B
Plume kit standard delivery additional
options:
• 2 x 87° bends
• 1 pipe 1m long
C
Plume kit standard delivery additional
options:
• 2 x 45° bends
• 1 pipe 1m long
Deduct 3m from the max. possible standard
concentric horizontal flue length and add the
standard plume kit max length to give max.
length of entire flue system. ie. 6m - 3m +
2m = 5m max.