Salt Indicator - Miele G 646 SC Operating Instructions Manual

Table of Contents

Advertisement

The salt indicator light comes on to no-
tify you that the reservoir is empty.
^ The reservoir should then be refilled
with dishwasher salt for reactivation.
(See: Filling the salt reservoir).
After the reservoir has been filled, the
water softener is automatically reacti-
vated the next time the dishwasher is
run. The salt indicator light may still be
illuminated during this process. It will
go out once the salt concentration has
reached the correct level.
If the water in your area is very soft and
constantly lower than 0.7 mmol (4 °d)
you do not need to add salt to the res-
ervoir. The salt indicator light, however,
will still come on, but should be ig-
nored.
(See "After sales service" for definition
of "PC").
17

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G 646 SC and is the answer not in the manual?

Questions and answers

David McMyn
January 18, 2025

How do I change/service a water inlet filter which is integrated with the inlet hose? Can’t detach or open it. Any ideas?

User image 678b97badfb78
1 comments:
Mr. Anderson
February 4, 2025

To change or service the water inlet filter on a Miele G 646 SC when it is integrated with the inlet hose, follow these steps:

1. Locate the filter: The filter is located in the screw connection of the valve on the water inlet hose.

2. Remove the rubber seal: Carefully take out the rubber seal from the connection.

3. Withdraw the filter: Use pointed pliers to gently pull out the filter.

4. Clean the filter: Rinse the filter under running water to remove any dirt or debris.

5. Replace the filter and seal: Ensure both the filter and seal are positioned correctly.

6. Reconnect the inlet hose: Screw the inlet hose back onto the stopcock securely.

Important Notes:
- Avoid submerging the plastic housing of the water connection in water, as it contains an electrical component.
- If your mains water has a high level of insoluble substances, consider installing a large-area filter between the stopcock and the water inlet hose.