Basic version 3, software version 3
Table of Contents

Advertisement

09.91
6.4

Device connection data

SINUMERIK reader T40 and T50
Cable Order No. 6FC9 340-8S.
Device data
Transfer rate
Character format
Settings on T40 reader
Switch block A:
1 2
3
4
5
ON ON -
OFF OFF OFF OFF OFF
Switch block B:
1 2
3
4
5
ON OFF OFF OFF OFF OFF OFF OFF
Settings on T50 reader
Jumper assignment at 27 P01:
not allocated
Jumper assignment at 27 P02:
Jumpers 2 and 5 closed
Jumper assignment at 27 S02:
Jumpers 1, 2, 3, 4 open
Operating notes
To automatically start from the
SINUMERIK 810T, the reader must be
ready to start, the "Reader start" LED
must be lit.
An exact character stop is not possible.
If programs are produced externally, and
several programs punched onto one tape,
at least 20 blanks must be left between
programs.
When punching programs from the
SINUMERIK 810T, these blank characters
are automatically generated, provided the
"Output without leader and trailer" setting
data bit is not set. (SD no. 5016, bit 1 for
interface 1 or SD no. 5024, bit 1 for
interface 2)
© Siemens AG 1990 All Rights Reserved
SINUMERIK 810T, GA3 (BN)
SINUMERIK reader T60 (hand-held
unit) Type GNT 2910
Cable Order No. 6FC9 344-2C.
Device data
Transfer rate
9600 baud
Character format
start bit
8 Data bits
2 Stop bits
Settings
DIP switch in unit
1
6
7
8
OFF OFF OFF OFF OFF OFF ON OFF
Operating notes
Before switching the device on, ensure that
6
7
8
the paper tape has been inserted. If there
is a fault, the green LED flashes.
Acknowledge by switching the device off
and on. Read-in start is controlled by the
SINUMERIK 810T.
Further operating conditions
The device stops precisely at character.
SINUMERIK WS 800
Cable Order No: 6FC9 344-1B. (RS232C
Device Data
Interface: RS232C (V.24) or
20 mA current loop (TTY)
Transfer rate
Character format
Setting of the interface module DF 20
Interface SS2
RS232C (V.24): no hardware setting
TTY : passive
6ZB5 410-0EP02
6 Data Interfaces
6.4 Device connection data
9600 baud
1 Start bit
8 Data bits
2 Stop bits
2
3
4
5
6
(V.24))
6FC9 344-1Q. (20 mA)
9600 baud
1 Start bit
8 Data bits
2 Stop bits
Socket X9
Jumpers
2 - 14 Receive
3 - 13
6 - 10 Transmit
7 -
9
7
8
6-5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sinumerik 810T and is the answer not in the manual?

Questions and answers

rana faisal
February 28, 2025

siemens 810t after battery changed the sms show on secreen programe is not in memory

1 comments:
Mr. Anderson
February 28, 2025

After changing the battery on the Siemens Sinumerik 810T, the program may not be in memory because the data was lost when the battery failed. This is indicated by a user reporting data loss after a battery failure, requiring a re-upload of backup files. If the backup is not restored correctly or is incomplete, the machine may display "program is not in memory."