Dsp Rx Equalizer; Equalizing Receiving Audio; Rx Monitor; Time-Out Timer - Kenwood TS-590S Instruction Manual

Hf/ 50 mhz all mode transceiver
Hide thumbs Also See for TS-590S:
Table of Contents

Advertisement

No.
Function
202
VOICE3
203
MONITOR
204
TX TUNE
205
DATA SEND
206
DOWN
207
UP
208
EMERGENCY
OFF
Note:
◆ Assigned key functions may not work, depending on the
setting.
◆ [AGC SEL] can be used in modes other than FM mode,
and can set a step level of the chosen AGC time constant
(FAST/ SLOW).
◆ [TONE SEL] can also be used in FM mode while TONE or
CTCSS is ON,

DSP RX EQUALIZER

EQUALIZING RECEIVING AUDIO

Use Menu No. 31 to change the receiver frequency
responses of the target signal. You can select one
from 8 different receiver profiles including the default
flat response. Selecting any of the following items
from the Menu causes "
display.
Off (oFF):
Slightly attenuates (1 kHz or higher audio
frequencies).
High boost 1 (hb1):
Emphasizes higher audio frequencies.
High boost 2 (hb2):
Emphasizes higher audio frequencies but lower
audio frequency attenuation is less than High
boost1 (hb1).
Formant pass (FP):
Improves clarity by suppressing audio frequencies
outside the normal voice frequency range.
Bass boost 1 (bb1):
Emphasizes lower audio frequencies.
Bass boost 2 (bb2):
Emphasizes lower audio frequencies but higher
audio frequency attenuation is less than Bass
boost1 (bb1).
Flat (FLAT):
The flat frequency response.
User (U):
Reserved for the ARCP software. Off is
programmed at the factory as a default.
Remark
The lower meter when
transmitting
Mic [PF4] default
The input voice from
the data terminal is
transmitted
Mic [DWN] default
Mic [UP] default
Emergency frequency
call (K type only)
No function
" to appear on the
12 OPERATOR CONVENIENCES

RX MONITOR

RX monitor temporarily disables the squelch function
to monitor the current frequency activities.
To use the RX Monitor function, first assign the
function to a PF key (either on the front panel or the
microphone).
1 Press [MENU], then press [Q-M.IN]/ [Q-MR] or
turn the MULTI/CH control to select Menu No.
79 ~ 86.
2 Press [M.IN]/ [SCAN (SG.SEL)] to select "203".
3 Press [MENU] to exit Menu mode.
4 Press the assigned [PF] key.
While pressing [PF], the speaker unmutes.

TIME-OUT TIMER

The Time-out Timer limits the time of each
transmission. It is also useful to prevent a long
accidental transmission.
1 Press [MENU], then press [Q-M.IN]/ [Q-MR] or
turn the MULTI/CH control to access Menu No. 49.
2 Press [M.IN]/ [SCAN (SG.SEL)] to select "oFF",
"3", "5", "10", "20", or "30" minutes.
3 Press [MENU] to exit Menu mode.

TRANSVERTER

If you have a transverter that converts the TS-590S
operating frequencies to other frequencies, you can
use this TS-590S transceiver as a transverter exciter.
Consult the instruction manual that came with the
transverter for interfacing to the TS-590S transceiver.

FREQUENCY DISPLAY

1 Connect the transverter to the ANT 1, ANT 2, RX
ANT, or DRV connector of the TS-590S.
2 Select the exciter operating frequency on the
transceiver.
The transverter will use this frequency as the
reference for converting frequencies.
3 Press [MENU], then press [Q-M.IN]/ [Q-MR] or
turn the MULTI/CH control to access Menu No. 50.
4 Press [M.IN]/ [SCAN (SG.SEL)] to select "1".
The output power is automatically set to the
lowest power for that frequency (default). Refer
to "TX POWER" {below}.
5 Press [MENU] to exit Menu mode.
6 Press [ENT], then set the target converting
frequency using the numeric keys.
7 Press [ENT] to complete the entry.
The transceiver displays the target transverter
frequency instead of the actual operating
frequency.
55

Advertisement

Table of Contents
loading

Table of Contents