Rheem CRITERION II Product Information Manual

Rheem CRITERION II Product Information Manual

80.0-82.2% a.f.u.e. downflow gas furnaces; models with input rates from 50,000 to 150,000 btu/hr [15 to 44 kw]

Advertisement

GAS FURNACES
RGLH- SERIES
Models with Input Rates from
50,000 to 150,000 BTU/HR
[15 to 44 kW]
ENER
UIDE
AFUE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
HIGH
78%
82%
88%
97%
CRITERION
80.0-82.2% A.F.U.E.
DOWNFLOW
GAS FURNACES
The Rheem
®
Criterion
®
II line of downflow gas furnaces is
designed for installation in closets, alcoves, utility rooms, or
attics. The design is certified by CSA.
Features
Patented heat exchanger, constructed of both stainless
and aluminized steel for the maximum in corrosion
resistance.
Low profile "34 inch" [864 mm] design is lighter and easier
to handle, and leaves room for optional equipment.
Left or right side gas and electric inlet connections with
quick, simple change.
Direct Spark ignition models and integrated board with
humidifier and electronic air cleaner hookups.
Insulated blower compartment helps to reduce jacket loss
and noise.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Grab-holes in doors to aid in easy door removal and
replacement.
A variety of cooling coils and plenums designed to use with
Rheem Criterion II gas furnaces are available as optional
accessories.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Energy test procedures.
FORM NO. G11-449 REV. 6
Supersedes Form No. G11-449 Rev. 5
®
II

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CRITERION II and is the answer not in the manual?

Questions and answers

Jason
February 4, 2025

Does my furnace have an electronic ignition for the pilot light

1 comments:
Mr. Anderson
February 10, 2025

Yes, the Rheem Criterion II furnace has a hot surface ignition (HSI) system, which is an electronic ignition method. It does not use a standing pilot light but instead relies on an HSI to ignite the burners.

This answer is automatically generated

태현
March 6, 2025

이 기종에 오류코드를 좀 알 수 있을까요? 파워버튼은 들어오는데 ok버튼이 두 번씩 깜빡거립니다.

1 comments:
Mr. Anderson
March 6, 2025

The error codes for the Rheem Criterion II furnace include the following:

1. 1 blink followed by a 2-second pause – 1-hour lockout
2. 2 blinks followed by a 2-second pause – Pressure switch is open
3. 3 blinks followed by a 2-second pause – Limit switch is open
4. 4 blinks followed by a 2-second pause – Pressure switch closed
5. 5 blinks followed by a 2-second pause – Additional code for deluxe models with twinning capabilities

If the OK button blinks twice, it indicates that the pressure switch is open.

This answer is automatically generated

태현
March 6, 2025

이 기종의 오류코드를 알고 싶습니다. 파워버튼은 정상작동하나 ok버튼이 깜빡거립니다.

Summary of Contents for Rheem CRITERION II

  • Page 1 Models with Input Rates from A variety of cooling coils and plenums designed to use with 50,000 to 150,000 BTU/HR Rheem Criterion II gas furnaces are available as optional [15 to 44 kW] accessories. A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.
  • Page 2: Components View

    Remote Sense In-Shot Burners STANDARD EQUIPMENT All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved Completely assembled and wired; induced draft; pressure switch; redundant kits must be used to convert from natural to L.P.
  • Page 3: Specifications

    [519-628 L/s] Furnace 100,000 [29 kW] R = 11 x 10 G = 1450-1750 CFM 125,000 [37 kW] [279 x 254 mm] [684-826 L/s] 150,000 [44 kW] J = 1800-2075 CFM [850-979 L/s] [ ] Designates Metric Conversions Rheem Manufacturing Company...
  • Page 4: Dimensions And Clearance

    May be 0" [0 mm] with type B vent. May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with ANSI Z21.47-1993 • CAN/CGA-2.3-M93 venting table guidelines, and in accordance with local codes. [ ] Designates Metric Conversions Rheem Manufacturing Company...
  • Page 5: Blower Performance Data

    1815 [857] 15NARJR HIGH —0000 2340 [1104] 2290 [1081] 2215 [1045] 2145 [1012] 2080 [982] 1995 [942] NOTES: *Not to be used as a heating speed. Data compiled with factory filters installed. [ ] Designates Metric Conversions Rheem Manufacturing Company...
  • Page 6: Combustible Floor Base Dimensions

    (Kit packaged with furnace. Requires field installation.) GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product Gas Heat Exchanger Limited Warranty ..Twenty (20) Years which fails in normal use and service within the applicable *Any Other Part..........One (5) Years...
  • Page 7 NOTES Rheem Manufacturing Company...
  • Page 8 Federal, State, Provincial, and Local codes, regulations, and practices. 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A. 11-01 DC FORM NO.

This manual is also suitable for:

Rglh-05eauerRglh-05nauerRglh-07eauerRglh-07nauerRglh-07eamgrRglh-07namgr ... Show all

Table of Contents

Save PDF