Do you have a question about the ZB Copeland Scroll and is the answer not in the manual?
Questions and answers
Ezequiel cano
February 13, 2025
Hi my name is Ezequiel and I **** loocking for a Rotolock valve for a compressor model # ZB11KCE-PFV-**** can you help me thanks
Daniel
February 28, 2025
hello what is "CH" used on compressor Type : One-stage hermetic scroll
. Model : ZB38KQE
Isaac Madrigan Gyebi
April 12, 2025
How scroll compressor looks like
1 comments:
Mr. Anderson
April 12, 2025
The Emerson ZB Copeland Scroll compressor contains two scroll members: one fixed scroll and one orbiting scroll. These scrolls form crescent-shaped gas pockets. The orbiting scroll moves in a circular motion without rotating, compressing gas toward the center where it is discharged. The outer part handles suction and the inner part handles discharge, both occurring continuously.
Series Index General Information Dimensions 46-65 Brazing Connection 46-49 Description of Features ZB15 ~ ZB29 (BOM 524) ZB38 ~ ZB48 (BOM 524) Nomenclature & BOM ZB58 (BOM 524) ZB66 ~ ZB88 (BOM 524) Application Envelope Rotalock Connection 50-53 ZB15 ~ ZB29 (BOM 523) R404A/R507 &...
Page 3
* Oil sight glass & Rotalock features Customers can be confident that ZB scroll compressors are coming from Emerson Climate Technologies experience of over 80 million scroll compressors. ZB scroll compressors are manufactured in our scroll factories in Suzhou, China and Rayong, Thailand. To our customers, this gives additional value by lower inventory and reduced shipping cost.
Page 4
Series Description of Features Dual Compliance Unloaded Start Compliance means sealing between the orbiting and fixed scroll The scroll sets separate at the instant of compressor shutdown. This involutes. Dual compliance means the sealing is on both the axial and allows the scroll set internal pressures to equalize on compressor radial directions.
Series Nomenclature & BOM Compressor Motor Protection Generation Code Description Inherent internal line break motor protector Electronic motor protection with Lubricant themistors and control module in Blank: Mineral Oil the terminal box E: Ester Oil Compressor Family Bill of Material Z B 7 6 K Q E - T F D - X X X High/Medium Temp Motor voltages...
Series Application Envelope ZB15 ~ ZB88 ZB95/ZB114 (TFD Motor Only) Evaporating Temp. Evaporating Temp. Note: Note: 1. Envelope In Non Shaded Region, max return gas temperature of 18.3°C 1. Envelope In Non Shaded Region, max return gas temperature of 18.3°C 2.
Page 7
Series Application Envelope R404A/R507 & R134a ZB15 ~ ZB88 ZB95/ZB114 R404A/R507 R404A/R507 Evaporating Temp. Evaporating Temp. Note: Note: 1. Envelope In Non Shaded Region, max return gas temperature of 18.3°C 1. Envelope In Non Shaded Region, max return gas temperature of 18.3°C 2.
Series Application Guide 1. Scroll Compression process Compression in the scroll is created by The open passages are sealed off As the spiral continues to orbit, the interaction of an orbiting spiral and as gas is drawn into the spiral. the gas is compressed into two a stationary spiral.
Series Application Guide 2. Compressor Internal Protections 2.2 Internal Scroll Temperature Protection Events such as loss of charge, condenser fan failure, or low side charging 2.1 Internal Pressure Relief Valve: with inadequate pressure will cause the discharge gas to quickly rise. Models ZB15- ZB48 has internal pressure relief valve, which open at a Excessively high discharge gas temperatures would affect the scroll discharge to suction differential pressure of 375 to 450 psi.
Series Application Guide Models ZB95KQ/E and ZB114KQ/E with motor protection code “W” use 3.2 Rotation Direction of Three Phase Scroll Compressors a combination of sensors and an electronic module (INT69SU) for motor Scroll compressors will only compress in one rotational direction. protection.
Page 11
A separate form may be requested (Form 93-11) other compressors. Due to the different thermal properties of steel which lists Emerson approved lubricants that may be used to recharge and copper, brazing procedures may have to be changed from those these compressors or if the addition of oil is required.
Series Application Guide 3.8 Special handling consideration for ZB58-ZB114 Three-phase models ZB58- ZB114 model compressors have the suction fitting located low on ZB15–ZB48- outdoor only the shell. Due to this, its recommended to leave the suction connection Crankcase heaters are required on three phase compressors where the plug in place until the compressor is set into the unit.
This compressor into the low side on shut down. Emerson recommends that phenomenon can occur with any compressor when the motor is the cut out setting of the pump-down pressure control be set no more immersed in refrigerant and does not present any safety issue.
Series Application Guide Proper indoor and outdoor blower/fan operation should be verified. • Determine the control voltage by using a voltmeter and then measure the voltage across the M1-M2 contacts: With service gauges connected to suction and discharge pressure If the measured voltage is equal to the control volts then the fittings, turn on the compressor.
S1-S2 then the module is faulty and should be replaced. Figure 2 Table 4 Technical Data Summary Of Module New Installations Emerson P/N 071-0641-00 • The copper-coated steel suction and discharge tubes on scroll Manufacturer P/N Kriwan 69SU Kriwan 69SU...
Page 16
Series Application Guide Field Service 6.2 Compressor Replacement after Motor Burn Unbrazing System Components In the case of a motor burn, the majority of contaminated oil will be removed with the compressor. The rest of the oil is cleaned through use CAUTION! of suction and liquid line filter dryers.
Series Electrical Wiring Diagram ZB15 ~ ZB114 Single Phase Circuit (ZB15-ZB29) Electrical Schematics L1/N/PE: Single Phase Lines (line/neutral/ground) Q1: Manual Switch F1/F6: Fuse K1: Compressor Contactor To Control Circuit C2: Run Capacitor M: Compressor Motor R/C/S: Compressor Terminal 3 Phase (ZB15-ZB114) (with Motor Protection Code “F”) Electrical Schematics F6...8...
Page 69
Series Electrical Wiring Diagram ZB15 ~ ZB114 Control Circuit 220/230 V Alternating Current Traditional Solid-state Timer (optional) Fuse Attention: If you use timer,do not connect A&B Exhaust-pipe Thermostat Compressor Connector Thermostat (Optional) CDU Fan connector Other protection (optional) device (optional) Crankcase heater 3 Phase (ZB95-114 TW*) (with Motor Protection Code “W”)
Page 70
Tel: (91-22) 2500 6630/ 2500 6632 Fax: (886-2) 2702 9630/ 2784 0022 Fax: (91-22) 2500 6570 China - Shanghai Thailand - Rayong Plant c/o Emerson Climate Technologies (Suzhou) Co. Ltd Indonesia c/o Emerson Electric (Thailand) Ltd Shanghai Sales Office PT. Emerson Indonesia No.
Need help?
Do you have a question about the ZB Copeland Scroll and is the answer not in the manual?
Questions and answers
Hi my name is Ezequiel and I **** loocking for a Rotolock valve for a compressor model # ZB11KCE-PFV-**** can you help me thanks
hello what is "CH" used on compressor Type : One-stage hermetic scroll . Model : ZB38KQE
How scroll compressor looks like
The Emerson ZB Copeland Scroll compressor contains two scroll members: one fixed scroll and one orbiting scroll. These scrolls form crescent-shaped gas pockets. The orbiting scroll moves in a circular motion without rotating, compressing gas toward the center where it is discharged. The outer part handles suction and the inner part handles discharge, both occurring continuously.
This answer is automatically generated