Porter-Cable C5510 Instruction Manual

Porter-Cable C5510 Instruction Manual

Oillube single-stage portable compressor

Advertisement

Oillube Single=Stage
Portable Compressor
IMPORTANT
Please make certain that the person who
is to use this equipment carefully reads
and understands
these instructions before
starting operations.
The Model and Serial No. plate is located on the frame.
Record these numbers
in the spaces below and retain for
future reference.
Model No.
Type
Serial No.
Part No.
A10260-052-0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C5510 and is the answer not in the manual?

Questions and answers

Summary of Contents for Porter-Cable C5510

  • Page 1 Oillube Single=Stage Portable Compressor IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference.
  • Page 2 This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols.
  • Page 3 Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. WARNING: Risk of explosion or fire How To Prevent It What Could Happen If electrical sparks...
  • Page 4 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could 'revent It Modifications or attempted repairs Never drill into, weld, or make any the tank.
  • Page 5 WARNING: Risk of Electrical Shock What Could Happen How To Prevent it Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with...
  • Page 6 WARNING: Risk of Burns I ,_,,_ .=,==,=,=== i What Could Hapjoen How To Prevent It WARNING: Risk from Moving Parts What Could Happen How To Prevent it Moving parts such as the pulley, flywheel, Never operate the compressor with and belt can cause serious injury if guards or covers which are damaged...
  • Page 7 WARNING: Risk of Serious injury or Property Damage When Transporting Compressor (Fire, Inhalation, Damage to Vehicle Surfaces) What Could Ha How To Prevent WARNING: Risk of Unsafe Operation How To Prevent It What Could Happen Review and understand all instructions Unsafe operation of your air compressor and warnings...
  • Page 8 Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SOFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters...
  • Page 9 Tools Required for Assembly 1 - 9/16" socket or open end wrench 1 - 1/2" socket or open end wrench Unpacking Remove unit from carton and discard all packaging. NOTE: Save all parts bags. To install Handle The wheels and handle do not provide adequate clearance, stability, or support for pulling the unit up and...
  • Page 10 If the handle has excessive movement, it is improperly installed. Check the following. Are both tabs inside the handle (Step #3)? Does each clip pass through both the saddle and handle (Step #4)? To Assemble Wheels lt will be necessary to brace or support one side of the...
  • Page 11 To Add Oil To Pump Compressors are shipped without oil. A small amount of oil may be present in the pump upon receipt of the air compressor. This is due to plant testing and does not mean the pump contains oil.
  • Page 12 HOW TO SET UP YOUR UNiT Location of the Air Compressor Locate the air compressor in a clean, dry, and well ventilated area. Place on a solid surface to prevent rocking or tipping. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.
  • Page 13 Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end.
  • Page 14 Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. On/Auto/Off Tank Pressure Switch Gauge...
  • Page 15 Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank.
  • Page 16 Before Each Start=Up: Place On/Auto/Off lever to "Off". Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero. Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.
  • Page 17 Customer Responsibilities Before Daily Every Every Every Every or after each each Yearly hours hours hours hours Check Safety Valve • Drain Tank • Oil Leaks • Check Oil • Change Oil • • Unusual Noise and/or IVibration • A_r Filter Drive Belt-Condition •...
  • Page 18 To Drain Tank NOTE: Operation of the air compressor will cause condensation to build up in the air tank. Always drain tank on a washable surface or in a suitable container to prevent damaging or staining surfaces. Set the On/Auto/Off lever to "Off".
  • Page 19 Air Filter = inspection and Replacement Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed. Allow compressor to cool prior to servicing. E__! Keep the air filter clean at all times. Do not operate air compressor with the air filter removed.
  • Page 20 Motor Pulley/Flywheel Alignment NOTE: Once the motor pulley has been moved from its factory set location, the grooves of the flywheel and pulley must be aligned to within 1/16" to prevent excessive belt wear. The air compressor flywheel and motor pulley must be in-line (in the same plane) within 1/16"...
  • Page 21 ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN. E_I_ isk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical...
  • Page 22 To Replace Regulator Release all air pressure from air I Quick Outlet Pressure Gauge Connect tank. See "To Drain Tank" in the "Maintenance" section. Set the On/Auto/Off lever to "Off" and unplug unit. Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator.
  • Page 23 Before you store the air compressor, make sure you do the following: Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. Set the On/Auto/Off lever to "Off" and unplug unit. Turn the regulator counterclockwise and set the outlet pressure to zero. Remove the air tool or accessory.
  • Page 24 Risk of Unsafe Operation. Unit cycles automatically when power is on. When performing maintenance, may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance repair, disconnect power source from the compressor and bleed off all air pressure.
  • Page 25 PROBLEM CORRECTION CAUSE it is normal for "some" If there is an excessive amount Pressure reading pressure drop to occur. of pressure drop when the on the regulated accessory is used, adjust the pressure gauge regulator as instructed in the drops when an Operation section.
  • Page 26 PROBLEM CAUSE CORRECTION Motor will not Let motor cool off and Motor overload protection overload switch will run. switch has tripped. automatically reset. Motor will start automatically Tank pressure exceeds when tank pressure drops pressure switch "cut-in" below "cut-in" pressure of pressure.
  • Page 27 CORRECTION PROBLEM CAUSE Knocking Noise. Possible defect in safety Operate safety valve manually valve. by pulling on ring. If valve still leaks, it should be replaced. Defective check valve. Remove and clean, or replace. Loose pulley. Tighten pulley set screw, see Parts manual for torque specifications.
  • Page 28 PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 YEARS...

Table of Contents