QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are for illustrative purposes only. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification.
Page 3
User’s Guide QConvergeConsole CLI 2400, 2500, 3200, 8100, 8200 Series Adapters Added glossary of terms used. Glossary SN0054667-00 B Page iii...
Page 4
User’s Guide QConvergeConsole CLI 2400, 2500, 3200, 8100, 8200 Series Adapters Page iv SN0054667-00 B...
This preface explains the QConvergeConsole CLI help system, describes the typographic conventions used in this guide, lists related documents, specifies the intended audience, refers you to the QLogic license agreements, and provides technical support and contact information. The remainder of the user's guide is organized into the following chapters: ...
This guide is for system administrators who are responsible for installing, configuring, and managing QLogic adapters using QConvergeConsole CLI. Related Materials For additional help installing or using QConvergeConsole CLI, refer to the following related documents posted on the QLogic Web site http://driverdownloads.qlogic.com: QConvergeConsole CLI Readme QConvergeConsole CLI Release Notes...
License Agreements Refer to the QLogic Software End User License Agreement for a complete listing of all license agreements affecting this product. SN0054667-00 B...
Technical Certification courses include installation, maintenance, and troubleshooting QLogic products. Upon demonstrating knowledge using live equipment, QLogic awards a certificate identifying the student as a certified professional. You can reach the training professionals at QLogic by e-mail at training@qlogic.com. Contact Information QLogic Technical Support for products under warranty is available during local standard working hours excluding QLogic Observed Holidays.
Technical Support Knowledge Database The QLogic knowledge database is an extensive collection of QLogic product information that you can search for specific solutions. We are constantly adding to the collection of information in our database to provide answers to your most urgent questions.
Page 26
Preface Technical Support xxvi SN0054667-00 B...
System Requirements QConvergeConsole CLI is an management utility that centralizes management and configuration of QLogic adapters within the entire network (LAN and SAN). For optimum performance, QConvergeConsole CLI requires the hardware, software, and operating systems listed in this section: ...
The software requirements for the server on which your adapter is physically installed are as follows: QLogic adapter drivers for your operating system NOTE: Refer to the QLogic Web site for QLogic adapter drivers and agents: http://driverdownloads.qlogic.com. Administrative privileges to perform management functions Operating System Requirements QConvergeConsole CLI runs on the following platforms: ...
Page 29
Supported QLogic Adapters 2400 and 2500 Series Fibre Channel Adapters 3200 Series Intelligent Ethernet Adapters 8100 and 8200 Series Converged Network Adapters NOTE: For information about QLogic adapters, refer to the QLogic Web site at http://www.qlogic.com/Products/adapters. SN0054667-00 B...
Installing QConvergeConsole CLI Uninstalling QConvergeConsole CLI NOTE: QConvergeConsole CLI is designed to configure QLogic adapters on the local machine (where it is installed). It cannot configure adapters on remote machines. Downloading QConvergeConsole CLI To download QConvergeConsole CLI from the QLogic Web site: On the QLogic home page (http://www.qlogic.com), click the Downloads...
2–Installing and Uninstalling QConvergeConsole CLI Installing QConvergeConsole CLI Figure 2-1. QLogic Products Download Selections (Example) On the downloads page for the selected adapter, scroll down to the Management Tools table, and then click the appropriate version of QConvergeConsole CLI for your operating system.
QConvergeConsoleCLI-<version>_win_x64.msi where <version> is the version number. The default directory for QConvergeConsole CLI utility is: Program files\QLogic Corporation\QConvergeConsoleCLI If you want to install the QConvergeConsole CLI in a different directory, enter it in the command line. For example: QConvergeConsoleCLI-<version>_win.msi installdir=<directory>...
2–Installing and Uninstalling QConvergeConsole CLI Installing QConvergeConsole CLI in a Linux Environment Passive Windows Installation Issue the following command for a passive installation using default values. For example: QCCCLI.msi /passive The preceding command installs with minimum interaction, showing only the progress bar and any errors.
Command Line Uninstall Start Menu Uninstall To uninstall from the Windows Start menu: Go to Start. Point to All Programs, QLogic Management Suite, and then click Uninstall QConvergeConsole CLI. Control Panel Uninstall To uninstall from the Control Panel: Go to Start, and then click Control Panel.
2–Installing and Uninstalling QConvergeConsole CLI Uninstalling QConvergeConsole CLI in a Linux Environment Uninstalling QConvergeConsole CLI in a Linux Environment To uninstall QConvergeConsole CLI on a Red Hat and SUSE Linux and PPC operating systems, issue the following from a command prompt: rpm -e QConvergeConsoleCLI-AA.BB.CC-DD SN0054667-00 B...
Using Interactive Mode Interactive mode is a menu-driven interface that manages QLogic Ethernet adapters, QLogic Fibre Channel Adapters, and all functions of QLogic Converged Network Adapters, including NIC, Fibre Channel, and iSCSI. Although the QConvergeConsole CLI contains menus for all of these adapter types, for clarity, Use administrator mode for Windows 2008 or later.
Double-click the QConvergeConsole CLI icon on the desktop. Click Start and point to All Programs, QLogic Management Suite, and then click QConvergeConsole CLI. Open a command prompt in the installation directory (default is C:\Program Files\QLogic Corporation\QConvergeConsoleCLI),...
3–Getting Started Main Menu Main Menu When you start QConvergeConsole CLI in interactive mode, the Main Menu appears as follows: Main Menu Adapter Information Adapter Configuration Adapter Updates Adapter Diagnostics Adapter Statistics Refresh Help Exit Please Enter Selection: Selecting an option from the Main Menu prompts you to choose an adapter type. ...
3–Getting Started Getting Help Getting Help Help is available in interactive mode using option 7. Help. Noninteractive mode provides help using the -h switch. For example, to list all of the available command line parameters, issue the following command: qaucli -h To list available online switches, issue the following commands for their respective adapter types: qaucli -pr iscsi -h...
4–NIC Noninteractive Commands Command Summary Command Summary This subsection lists and describes each command line option in alphabetic order, followed by a command description. -beacon (Enable/Disable Port Beacon) To toggle on and off the port beacon (LED), issue the -beacon command as follows: >...
4–NIC Noninteractive Commands For example: > qaucli -pr nic -ch 1 === Displaying CNA config info for 1. CNA Port Index === CNA_Alias CNA X54 To generate XML discovery output, issue the -d command as follows: > qaucli -pr nic -d <flash_file> [xml_output_file] where flash_file is the Flash file and xml_output_file is the XML discovery output.
The QConvergeConsole CLI help file contains a condensed version of the contents of this chapter. (List All QLogic CNA Ports Detected) To view a list of all QLogic adapter ports detected, issue the -i command as follows: > qaucli -pr nic -i [cna_port_inst] For example: >...
4–NIC Noninteractive Commands -icna (CNA Information) -icna (CNA Information) To view adapter information, issue the -icna command as follows: > qaucli -pr nic -icna [cna_port_inst] For example: > qaucli -pr nic -icna 2 === CNA Information for 2. CNA Port Index === Hostname : WIN-4ZKSPMU5N5L Adapter Model...
4–NIC Noninteractive Commands -intloopback (Configure Test Parameters) For example: > qaucli -pr nic -idcbx 1 -------------------------------- DCBX -------------------------------- DCBX Enable : Enabled DCBX Negotiation : Successful Port Pause Type : Per Priority Pause -------------------------------- -------------------------------- Priority Tx Mode : Bandwidth SAN Unused BW to LAN : Disabled LAN Unused BW to SAN...
4–NIC Noninteractive Commands -iset (Display Configured Port Settings) -iset (Display Configured Port Settings) To view configured port settings, issue the -iset command as follows: > qaucli -pr nic -iset [cna_port_inst] For example: > qaucli -pr nic -iset 1 === Configured Port Settings for 1. CNA Port Index === Header_Data_Split_Enable : off IPv4_Large_Send_Offload_v1_Enable...
4–NIC Noninteractive Commands -n (Change Port Alias Name) (Change Port Alias Name) To change port alias names, issue the -n command as follows: > qaucli -pr nic -n [cna_port_inst] <config_name|config_alias> <value> [<config_name|config_alias> <value>] For this release of QConvergeConsole CLI, you can set the following properties: ...
: 1514 Interface Scope ID : 91 Interface Speed : 10 Gbps Interface Description : QLogic 10Gb PCI Ethernet Adapter - Network Load Balancing Filter Device === Port Information for 2. CNA Port Index === . . . -ping (Ping Target) To run a ping diagnostic, issue the -ping command as follows: >...
4–NIC Noninteractive Commands -statport (Display Ethernet Port Statistics) -statport (Display Ethernet Port Statistics) To view the Ethernet port statistics, issue the -statport command as follows: > qaucli -pr nic -statport [cna_port_inst] 4-12 SN0054667-00 B...
Page 53
4–NIC Noninteractive Commands -statport (Display Ethernet Port Statistics) For example: > qaucli -pr nic -statport 1 Port statistics for 1. CNA Port Index txPkts : 12989 txOctets : 2302620 txMulticastPkts : 8444 txBroadcastPkts : 4195 txUnicastPkts : 350 txControlPkts txPausePkts txPkts64Octets : 1013 txPkts65to127Octets...
> qaucli -pr nic -sunreset 1 Port statistics undo reset for 1. CNA Port Index -svmtool SVM is a general purpose utility that displays and configures settings for QLogic Converged Network Adapters. To update the SVM firmware, issue the -svmtool command as follows: >...
To delete a team, issue the -teamdel command as follows: > qaucli -pr nic -teamdel <team_inst|ALL> For example: > qaucli -pr nic -teamdel 3 About to delete team: 1 (QLogic VT-IM Miniport Driver #2). Please wait ... Successfully deleted team: 1 () -teaminfo...
4–NIC Noninteractive Commands -testflash -testflash To test the Flash memory, issue the -testflash command as follows: > qaucli -pr nic -testflash [cna_port_inst] -testhw To test the hardware, issue the -testhw command as follows: > qaucli -pr nic -testhw [cna_port_inst] -testinterrupt To test the interrupt, issue the -testinterrupt command as follows: >...
> qaucli -pr nic -v > qaucli -pr nic -ver For example: > qaucli -pr nic -ver Using config file: G:\Program Files\QLogic Corporation\QConvergeConsoleCLI\qaucli.cfg Installation directory: G:\Program Files\QLogic Corporation\QConvergeConsoleCLI Working dir: G:\Documents and Settings\user1 Using config file: G:\Program Files\QLogic Corporation\QConvergeConsoleCLI\netscli.cfg...
ListIndex: 1 CNA: 1 CNA Port: VLAN ID: 453 MAC: 00:c0:dd:12:0f:f4 Description: QLogic 10Gb PCI Ethernet Adapter -vlaninfo (Display VLAN Information) To view information about the VLAN, issue the -vlaninfo command as follows: > qaucli -pr nic -vlaninfo <vlan_inst|ALL> For example: >...
Page 64
If you do not specify a file name, QConvergeConsole CLI reads the default file (vtstate.cfg) in the installation directory For example: >qaucli -pr nic -vtcfgview c:/system_1.cfg Using config file: E:\Program Files\QLogic\Corporation \QConvergeConsoleCLI\netscli.cfg Accessing file: c:/system_1.cfg Number of Teams: 1 ----------------...
NOTE: The -vtrestore command can restore a configuration file produced only by the -vtsave command. Similarly, a configuration that is saved using the QLogic Windows Teaming Property pages can be restored only with the Windows Teaming Property Pages. For example: >qaucli -pr nic -vtrestore c:/system_1.cfg...
A configuration that is saved with the -vtsave command can be restored only with the -vtrestore command. Similarly, a configuration that is saved using the QLogic Windows Teaming Property pages can be restored only with the Windows Teaming Property Pages.
Fibre Channel Noninteractive Commands This chapter describes the noninteractive Fibre Channel command format and parameters of QConvergeConsole CLI. For a quick reference to informative commands, see Display System Information (Command Line Options -g, -z, and -tp). NOTE: To view help, enter the command -h. Display System Information (Command Line Options -g, -z, and -tp) When you enter one of these options, general information appears in various...
(adapter 0–n), and status (online/offline) Total number of QLogic Fibre Channel adapters detected NOTE: The failover and SAN device management APIs are QLogic-specific libraries required for QConvergeConsole CLI. The versions of these libraries are useful for debugging purposes. Host Configuration...
5–Fibre Channel Noninteractive Commands Host Configuration Host Configuration Use these options to show the information for one or all of the adapter ports in the system. The -z option shows the combination of the commands listed in Table 5-1. The commands are listed in alphabetical order. Table 5-1.
5–Fibre Channel Noninteractive Commands Command Format You can combine the commands -o, -s and -x with other options. However, they must be at the beginning or at the end of the command line. Use these commands as follows: -o = Output the results to a file (see “-o (Output to a File)”...
5–Fibre Channel Noninteractive Commands Command Summary Table 5-2. Command Variables (Continued) Variable Definition Format <target port id> Target port ID xx-xx-xx or xxxxxx <target id> Target ID <lun id> Logical unit number (0–255) IP address xxx.xxx.xxx.xxx <address> Target link speed 1.2, 4, or 8GHz (speed) You can use the -g command to find adapter numbers.
5–Fibre Channel Noninteractive Commands -b (Save or Update the Flash BIOS or FCode) QConvergeConsole CLI toggles the LED’s state. If the LED is flashing, the flashing stops. If the LED is not flashing, the flashing begins. If QConvergeConsole CLI is not in silent mode (see “-s (Silent Mode)”...
5–Fibre Channel Noninteractive Commands -c (Show Parameter Settings) Where: hba instance = Adapter number (use -g command to find) hba wwpn = World wide port name of the adapter BIOS/FCode File = File name or a path to a file in which to save BIOS/FCode Name NOTE: The option to save the FCode to a file type is not supported for QLE8242.
5–Fibre Channel Noninteractive Commands -cna (FCoE Utilities Menu for QLx81xx Adapters) To view general information for the adapter, issue the following command: qaucli -pr fc -cna <hba instance>|<hba wwpn> --geninfo To view data center bridging exchange protocol settings, issue the following command: qaucli -pr fc -cna <hba instance>|<hba wwpn>...
5–Fibre Channel Noninteractive Commands -dm (Display Diagnostics Monitoring Info) (Display Diagnostics Monitoring Info) This option allows you to show general or detailed digital diagnostic monitoring interface for optical transceivers. NOTE: This option is supported only for QLA/QLE/QEM24xx (4GB) adapters. To show transceiver monitoring general information, issue the following command: # qaucli -pr fc -dm (<hba instance>...
Page 80
5–Fibre Channel Noninteractive Commands -e (Boot Device View | Select | Disable) To view the current boot device selection on all adapters: # qaucli -pr fc -e (view | info) To view the current boot device selection for a specific adapter: # qaucli -pr fc -e (<hba instance>...
5–Fibre Channel Noninteractive Commands -ei (List Fibre Channel Error Codes) QConvergeConsole CLI checks all parameters to verify that the adapter, targets, and LUNs are valid. If you select an adapter with no target or a target with no LUN, QConvergeConsole CLI shows an error message and aborts. For all operating systems, if the adapter already has boot devices defined and they are different from the ones in the command parameter or menu selection, you are prompted to confirm the boot device selection:...
5–Fibre Channel Noninteractive Commands -fg (Show Driver Settings) The file must contain only parameters. The file cannot contain another -f option. The following example shows how to set the connection option of an adapter to default (loop preferred, otherwise point-to-point) and the data rate to auto through a command file that is invoked by the -f option: Create a text file (for example, setadapter0.txt) and enter the following command in the text file:...
5–Fibre Channel Noninteractive Commands -fs (Configure Driver Settings) Where: hba instance = Adapter instance number of an adapter port (use -g command to find) hba wwpn = World wide port name of the adapter param name = Name of the parameters param alias = Alias of the parameters param value = New value of the parameters The pairs <param name>...
5–Fibre Channel Noninteractive Commands -gs (Show HBA Statistics) (Show HBA Statistics) To view the adapter statistics, issue the following command: # qaucli -pr fc -gs <hba instance> | <hba wwpn>) [(<param name> | <param alias>) <param value>] Where: hba instance = Adapter number (use -g command to find) hba wwpn = World wide port name of the adapter param name = Name of the parameter (see table 4-7)
5–Fibre Channel Noninteractive Commands -i (Display HBA General Information or VPD Information for One or All HBAs) Where: hba instance = Adapter number (use -g command to find) hba wwpn = World wide port name of the adapter alias = Symbolic adapter name. (100 characters, maximum) To set an alias for the selected adapter: # qaucli -pr fc -ha (<hba instance>...
5–Fibre Channel Noninteractive Commands -kl (Run Loopback Test) (Run Loopback Test) Use the -kl command to perform an external loopback test. To perform a loopback test using the default parameters, issue the following command: # qaucli -pr fc -kl (<hba instance> | <hba wwpn>) To do an external loopback test with customized parameters, issue the following command: # qaucli -pr fc -kl (<hba instance>...
5–Fibre Channel Noninteractive Commands -kr (Run Read/Write Buffer Test) (Run Read/Write Buffer Test) Use the -kr command to do read/write buffer test. To do a read/write test using the default parameters, issue the following command: # qaucli -pr fc -kr (<hba instance> | <hba wwpn>) To do a read/write test with customized parameters, issue the following command: # qaucli -pr fc -kr (<hba instance>...
Page 89
5–Fibre Channel Noninteractive Commands -kr (Run Read/Write Buffer Test) uses the SCSI Read Buffer command to read the returned data and do a data comparison. NOTE: All devices attached to the adapter must support SCSI Read/Write Buffer commands. To do a read/write buffer test using the current parameters, issue the following command: # qaucli -pr fc -kr (<hba instance>...
5–Fibre Channel Noninteractive Commands -kr (Run Read/Write Buffer Test) An example of a successful read/write buffer test follows: HBA 1: QEM2462 Port 1 WWPN xx-xx-xx-xx-xx-xx-xx-xx Port ID 02-0E-00 ------------------ Test Configuration ------------------ Data Pattern : Random Data Size (Bytes) : 512 Number of test(s) (0-65535) : 500 Test Increment (1-65535)
Page 91
5–Fibre Channel Noninteractive Commands -kr (Run Read/Write Buffer Test) Table 5-6. Diagnostics Parameters (Continued) Alias Name Value <param Description <param name> <param value> alias> 8, 16, 32, 64, 128, 256, Actual data transferred dur- DataSize 512, 1024, 2048 ing any given pass of the test 0–65535 Loopback test only...
5–Fibre Channel Noninteractive Commands -kr (Run Read/Write Buffer Test) Table 5-7. Data Pattern (DP) Test Patterns Binary 00000000 01010101 01011010 10100101 10101010 11111111 If the read/write buffer test fails, the system shows the following information: Loop/port ID (the loop ID of the adapter when operating in loop mode). ...
5–Fibre Channel Noninteractive Commands -l (Display LUN Info) (Display LUN Info) This command shows LUN information for: All adapters A specific target A specific LUN on a specific target To show the LUN information for all target devices for a specific adapter Instance, issue the following command: # qaucli -pr fc -l (<hba instance>...
5–Fibre Channel Noninteractive Commands -m (View, Enable, or Disable LUNs) Table 5-8 defines the link status parameter names, aliases, and values. Table 5-8. Link Status Parameters Description Name Alias Value Sets link-status retrieval period AutoPoll 0–256 cycles Sets link-status retrieval polling interval 5–30 seconds PollRate Save link status to CVS log file...
Page 95
5–Fibre Channel Noninteractive Commands -m (View, Enable, or Disable LUNs) To view all selective LUNs for all adapter ports, issue the following command: # qaucli -pr fc -m all (view | info) To view an adapter’s selective LUN list, issue the following command: # qaucli -pr fc -m (<hba instance>...
5–Fibre Channel Noninteractive Commands -n (Set Selected HBA Parameter) To disable (deselect) all LUNs for a specific target on a specific adapter, issue the following command: # qaucli -pr fc -m (<hba instance> | <hba wwpn>) deselect | disable <target wwnn> <target wwpn> To enable (select) all LUNs of all targets on a specific adapter: # qaucli -pr fc -m (<hba instance>...
Page 97
5–Fibre Channel Noninteractive Commands -n (Set Selected HBA Parameter) Table 5-9. Adapter Parameters (Continued) Description Name Alias Value Enable Fibre Channel 1=Enable, 0=Disable EnableFCTape tape Enable hard loop ID 1=Enable, 0=Disable EnableHardLoopID Enable LIP full login 1=Enable, 0=Disable EnableLIPFullLogin Enable LIP reset 1=Enable, 0=Disable EnableLipReset Enable target reset...
5–Fibre Channel Noninteractive Commands -o (Output to a File) Operation mode (QLA/QLE23xx, QLA/QLE24xx, and QLE2562): 0 = interrupt for every I/O completion 5 = interrupt when interrupt delay timer expires 6 = interrupt when interrupt delay timer expires or no active I/O NOTE: QLA200/210 adapters have a limited set of parameters that can be changed.
Page 99
5–Fibre Channel Noninteractive Commands -p (Display Persistent Target Binding Info) NOTE: Under Linux, if you use the IOCTL or sysfs (inbox) driver these features are disabled. To show target persistent binding information for a specific adapter port, issue the following command: # qaucli -pr fc -p (<hba instance>...
5–Fibre Channel Noninteractive Commands -pa (Define Port Alias) target port id = Port ID of the target target id = ID to which the target is bound To bind multiple targets with a single command, repeat the following group: <target wwnn> <target wwpn> <target port id> <target id> To bind all targets on a specific adapter or to bind all targets on all adapters, issue the following command: # qaucli -pr fc -p (<hba instance>...
5–Fibre Channel Noninteractive Commands -q (View or Set Target Link Speed) Where: hba instance = Adapter number (use -g command to find) hba wwpn = World wide port name of the adapter alias = Symbolic name you assign to the adapter port To delete a port alias for the specified adapter port, issue the following command: # qaucli -pr fc -pa (<hba instance>...
5–Fibre Channel Noninteractive Commands -r (Update HBA Parameters) To set the link speed of all targets attached to one adapter or all adapters to the designated speed, enter the following command: # qaucli -pr fc -q (<hba instance> | <hba wwpn> | <all>) <-targets | -t ><speed>...
5–Fibre Channel Noninteractive Commands -s (Silent Mode) To save the adapter parameters to a file, issue the following command: # qaucli -pr fc -r (<hba instance> | <hba wwpn>) save <File Name> Where: hba instance = Adapter number (use -g command to find) hba wwpn = World wide port name of the adapter hba parameters file = File name or a path to a file to save the adapter parameters...
5–Fibre Channel Noninteractive Commands -t (Display Target Information) This feature is supported with 8Gb mezzanine and blade adapters. It is not needed with the standard QLE2562 adapters. (Display Target Information) To show the target information for all adapters in the system, issue the following command: # qaucli -pr fc -t [ <all>...
QConvergeConsole CLI v1.x.x Build x Copyright 2003-2009 QLogic Corp. All rights reserved. Command Line QLogic FC Host Bus Adapters. Build Type: Release Build Date: xx/xx/xxxx xx:xx:xx AM (Virtual Port) To list all virtual ports on a physical adapter port, issue the following command: # qaucli -pr fc -vp (<hba instance>...
5–Fibre Channel Noninteractive Commands -x (Output in XML Format 1) To create a virtual port with a specific WWPN, issue the following command: # qaucli -pr fc -vp (<hba instance> : <hba wwpn>) create <vport hex> When prompted, enter two hexadecimal digits. The system checks these digits to be sure they are unique and, if they are, puts them into byte 1 of the WWPN.
5–Fibre Channel Noninteractive Commands -z (Display All HBA information for One or All HBAs) option (see “-o (Output to a File)” on page 5-28) to create a text file with XML output so that it can be parsed by an XML-compliant utility. For example, to show adapter general information and output it to an XML file named output.xml: # qaucli -pr fc -i all -x2 -o output.xml (Display All HBA information for One or All HBAs)
Noninteractive Commands This chapter describes the noninteractive iSCSI command format and parameters of QConvergeConsole CLI for the QLogic 8242 Converged Network Adapter. NOTE: To view help, enter the command -h. Command Format The noninteractive iSCSI command format is as follows: qaucli -pr iscsi [optional parameters] <Command Option>...
6–iSCSI Noninteractive Commands Command Summary Table 6-1. Noninteractive Command Variables (Continued) Variable Definition CHAP Number Challange handshake authentication protocol (CHAP) num- CHAP Name Null-terminated CHAP name, which is sent by the port instance when responding to the CHAP challenge CHAP Secret CHAP secret, which is used by the port instance when gener- ating the CHAP response Boot Target The target ID of the target device from which to boot Boot LUN The LUN of the boot device...
6–iSCSI Noninteractive Commands -acb -acb To inquire whether the access method control block (ACB) firmware functions are supported, issue the -acb command. In general, up-to-date firmware and driver are required for ACB to be supported. -addchap (Add a CHAP Entry) To add a CHAP entry to the persistent CHAP table, issue the -addchap command as follows: -addchap [-BIDI] <hba_port_inst>...
The -bootcode command updates the boot-code image, which should be done when QLogic releases a new boot code with bug fixes or enhancements. At the prompt, type the name of the file containing the boot-code image to upload to the adapter.
6–iSCSI Noninteractive Commands -c (Display Configured Port Settings) (Display Configured Port Settings) To view the configured settings for the port, issue the -c command as follows: -c [hba_port_inst] When you specify a port instance, information for only that adapter is shown. When you do not specify a port instance, information for all adapter ports in the system is shown.
6–iSCSI Noninteractive Commands -d (Install HBA Driver, All Adapters) (Install HBA Driver, All Adapters) To install an adapter driver for all iSCSI adapters on the system from a .zip or .inf file, issue the -d command as follows: -d <file_name> A system reboot may be required;...
6–iSCSI Noninteractive Commands FW version FW attribute FW version 2 FW attribute 2 Use the -dp command to preinstall an adapter driver specified from a .zip or .inf file. This operation may be performed without an adapter installed in the system.
6–iSCSI Noninteractive Commands -dtdsp (Display Discovered Targets) -dtdsp (Display Discovered Targets) To view the discovered targets that are not persistent, issue the -dtdsp command as follows: -dtdsp <hba_port_inst> -dtdspa (List Targets) To view discovered targets, including both persistent and nonpersistent, issue the -dtdspa command as follows: -dtdspa <hba_port_inst>...
6–iSCSI Noninteractive Commands -dtlia (Login and Persist a Discovered Target) -dtlia (Login and Persist a Discovered Target) To log in all discovered targets, issue the -dtlia command as follows: -dtlia <hba_port_inst> -dtrem (Remove Discovered Target) To remove a nonpersistent discovered target, issue the -dtrem command as follows: -dtrem <hba_port_inst>...
6–iSCSI Noninteractive Commands -edchap (Edit a CHAP Entry) -edchap (Edit a CHAP Entry) To change the value of the specified CHAP entry, issue the -edchap command as follows: -edchap <hba_port_inst> <CHAP> <Parameter> | <Parameter Alias> <Value> [<Parameter> | <Parameter Alias> <Value> …] You can repeat the <Parameter>|<Parameter Alias>...
-pr iscsi –h >file.txt (List All QLogic iSCSI HBA Ports Detected) Use the -i command to view a list of all detected adapter port instances (“ports”) in the system. Each port instance (hba_port_inst) is identified by its number.
Connection medium IP address (IP address of the adapter port instance) iSCSI name (adapter port iSCSI name; the QLogic default name or one you assign) Alias (adapter port instance iSCSI alias name that you assign) Figure 6-1 shows how to read the display.
6–iSCSI Noninteractive Commands -ipdhcp (Configure IP Settings) C = Configure the CHAP table. B = Configure the boot parameters (only valid when the T [targets] parameter is also specified). file_name = The XML file with the adapter configuration. See “-save (Save Host Configuration)”...
6–iSCSI Noninteractive Commands -isns6 (iSNS Settings) -isns6 (iSNS Settings) To configure the iSNS settings for IPv6 (QLE406x and newer), issue the -isns6 command as follows: -isns <hba_port_inst> [iSNS IPv6-or-IPv4 Address] [-iSNSPORT <port_number>] If you do not specify the [iSNS IPv6-or-IPv4 Address] parameter, this command disables the iSNS client on the specified adapter port.
6–iSCSI Noninteractive Commands For example, to link a CHAP entry 9 on port 2 to target 10 with BIDI CHAP turned on, issue the following command: -linkchap 2 9 10 TGTBCA on This command does not reset the adapter. The IPv6 local prefix list is created based on prefix information from router advertisements.
Page 125
6–iSCSI Noninteractive Commands -n (Configure iSCSI Settings) Table 6-3. Adapter Parameters (Continued) Configuration Name Configuration Alias Value IP Options IP_ARP_Redirect IPARP on or off IP_Address IPAD IP address format IP_Subnet_Mask IPSM IP address format IP_Gateway IPGW IP address format iSCSI Options Force_Negotiate_Main_iSCSI_ Keys iSCSI_Alias...
6–iSCSI Noninteractive Commands -nc (Display Neighbor Cache) Table 6-3. Adapter Parameters (Continued) Configuration Name Configuration Alias Value TCP Options TCP_Auto_Discovery SLPADIS on or off TCP_DHCP TCPDHCP on or off TCP_Nagle TCPN on or off TCPMaxWindowSize TCPMWS 1000h–FFFFh TCP_Time_Stamp TCPTMS on or off Miscellaneous Options KeepAliveTO KATO...
6–iSCSI Noninteractive Commands -netconf6 (Configure IPv6 Settings) Setting the IP address, subnet mask, or gateway turns off DHCP address resolution for the IP configuration, if it is on. -netconf6 (Configure IPv6 Settings) To manually configure the IPv6 network settings, issue the -netconf6 command as follows: -netconf6 <hba_port_inst>...
6–iSCSI Noninteractive Commands -nh (Configure iSCSI Settings) To set only the local link address, issue the following command: -netconf6 0 -IPLL fe80::1 To set everything automatically, issue the following commmand: -netconf6 0 -IPLLA -IPR01A -IPRRA To disable the IPv4 network, issue the following command: -netconf6 0 -DISN4 To disable the IPv4 and IPv6 networks, issue the following command: -netconf6 0 -DISN4 DISN6...
6–iSCSI Noninteractive Commands -pbootcode (Set Primary Boot Target Information) -pbootcode (Set Primary Boot Target Information) To set the primary boot-code boot target and LUN, issue the -pbootcode command as follows: -pbootcode <hba_port_inst> <tgt> <lun> This command is not active for the PPC. For information on secondary boot code, see “-sbootcode (Set Secondary Boot Target Information)”...
6–iSCSI Noninteractive Commands -ping (Ping Target) -ping (Ping Target) To ping the target device, issue the -ping command as follows: -ping <hba_port_inst> <IP Address> <Ping Count> <Packet size> <IPv6 source address> The following provides the IPv6 source address values: 0 = Do not care 1 = Local link 2 = Address 0 3 = Address 1...
6–iSCSI Noninteractive Commands -r (Update ROM Image) (Update ROM Image) CAUTION! Before attempting to update the ROM image, contact QLogic Customer Support. Before updating the ROM image, ensure that no I/O processes are running. An administrator must take necessary actions to ensure changes are fully recognized by the operating system (reboot, flush cache, sync disk, and so forth).
Page 132
6–iSCSI Noninteractive Commands -rwt (Perform Read/Write Buffer Test) Where: hba_port_inst = Adapter port whose factory settings you want to restore. A = Restore the factory settings for the entire adapter (firmware parameters, network parameters, iSCSI name, targets, CHAP table, NVARAM, and IPSec). Issuing this command resets the adapter.
6–iSCSI Noninteractive Commands -save (Save Host Configuration) Where: –STOP = Stop the test if a failure occurs. –RWPAT n = Set the pattern to write to the buffer, one of the following: n = 1 (8 bytes of 0x55h) (default) n = 2 (8 b.0tes of 0x5Ah) n = 3 (16 bytes of 0xAAh) n = 4 (16 bytes of 0xFFh)
6–iSCSI Noninteractive Commands -sdmrc -sdmrc To return the SDM library return code, issue the -sdmrc command as follows: -sdmrc [Simple_Pattern] When [ ] is given, only the lines containing that string are simple pattern printed. -stadd To add a send target for discovery, issue the -stadd command as follows: -stadd <hba_port_inst>...
6–iSCSI Noninteractive Commands -stathba -stathba To display adapter-level statistics, issue the -stathba command as follows: -stathba <hba_port_inst> -stdsp To view the send targets, issue the -stdsp command as follows: -stdsp <hba_port_inst> To use the -stdsp command, you must first issue the -stadd command at least once to add a send target for discovery only.
To view the QConvergeConsole CLI utility version, issue the -ver command as follows: -ver -vpd (Display VPD Information) To view VPD information, if any, issue the -vpd command as follows: -vpd <hba_port_inst> Available VPD information varies by adapter manufacturer. QLogic adapters ship with VPD information shown as N/A. 6-28 SN0054667-00 B...
NIC Interactive Commands This section describes the interactive mode command line options for Intelligent Ethernet Adapters. The interactive mode uses a series of menus from which you select the option you want and enter the number for that option. For information on non-interactive mode operation—in which you simply enter a one- or two-letter code to perform operations on the adapter refer to Section...
7–NIC Interactive Commands Adapter Information Adapter Information 1. Adapter Information1. Converged Network Adapter From the main menu, select the Adapter Information option, and then select the adapter type (Converged Network Adapter). The Converged Network Adapter Information menu presents options for viewing information about the adapter, ports, and VPDs.
7–NIC Interactive Commands CNA Adapter Information (-icna) CNA Adapter Information (-icna) 1. Adapter Information1. Converged Network Adapter1. CNA Adapter Information From the Converged Network Adaptor Information menu, select the CNA Adapter Information option. From the adapter menu, and then select the adapter (CNA Model) for which to view adapter information.
7–NIC Interactive Commands Adapter Configuration Adapter Configuration 2. Adapter Configuration1. CNA Configuration From the main menu, select the Adapter Configuration option, and then select the adapter type (CNA Configuration). The Converged Network Adapter (CNA) NIC Configuration menu presents options to configure the adapter alias and the NIC port settings.
7–NIC Interactive Commands NIC Port Setting Configuration Display Configured Port Settings (-iset) 2. Adapter Configuration1. CNA Configuration2. NIC Port Setting Configuration<port selection> 1. Display Configured Port Settings From the Port Settings Menu, select the Display Configured Port Settings option to view the configure port parameters. For example: IPv4_Checksum_Offload_Enable : RxTx Jumbo_Frames_MTU_9000_Enable...
7–NIC Interactive Commands Adapter Updates Change Port Alias Name (-n) 2. Adapter Configuration1. CNA Configuration2. NIC Port Setting Configuration<port selection> 3. Change Port Alias Name From the Port Settings Menu, select the Change Port Alias Name option to change the port alias. For example: Port_Alias [None]: port_alias Successfully saved Port Alias Change MAC Alias Name (-n)
7–NIC Interactive Commands Flash Update (-updimages) Flash Update (-updimages) 3. Adapter Updates1. Converged Network Adapter1. Flash Update From the CNA Adapter Update menu, select the Flash Update option to update flash memory. From the adapter menu, select an adapter for which to update flash memory, and then type the name of the file that contains the Flash image.
7–NIC Interactive Commands Register Test (-testregister) Register Test (-testregister) 4. Adapter Diagnostics1. Converged Network Adapter1. Register Test From the Converged Network Adapter (CNA) Diagnostics menu, select the Register Test option. From the port menu, select a port for which to test the Converged Network Adapter (CNA) Diagnostics CNA Model QLE3242 SN: AFE1030C04339...
7–NIC Interactive Commands Interrupt Test (-testinterrupt) Interrupt Test (-testinterrupt) 4. Adapter Diagnostics1. Converged Network Adapter3. Interrupt Test From the Converged Network Adapter (CNA) Diagnostics menu, select the Interrupt Test option. From the port menu, select a port for which to test the interrupts.
7–NIC Interactive Commands Beacon/LED Test (-testled) Link Test Results: Status=Failed Passed=0, Failed=1, ErrorCode=15 Beacon/LED Test (-testled) 4. Adapter Diagnostics1. Converged Network Adapter6. Beacon/LED Test From the Converged Network Adapter (CNA) Diagnostics menu, select the Beacon/LED Test option. From the port menu, select a port to run the test. For example: Converged Network Adapter (CNA) Diagnostics CNA Model QLE3242...
7–NIC Interactive Commands Display NIC Port Statistics (-statport) Display NIC Port Statistics (-statport) 5. Adapter Statistics1. Converged Network Adapter1. Display NIC Port Statistics From the Converged Network Adapter (CNA) Statistics menu, select the Display NIC Port Statistics option. From the port menu, select a port for which to view NIC port statistics.
6. Refresh From the main menu, select the Refresh option to refresh (reload) the adapters and adapter port indexes. For example: Scanning for QLogic adapters, please wait... Using config file: C:\Program Files\...\iscli.cfg Using config file: C:\Program Files\...\netscli.cfg Loading: 1. CNA ... adapters, please wait...
7–NIC Interactive Commands Help (-h) Help (-h) 7. Help From the main menu, select the Help option to view the syntax and description for each noninteractive command line option. For more detailed information about each command, see the noninteractive section for the specific adapter type. Exit 8.
Fibre Channel Interactive Commands This section describes the interactive mode command line options for Fibre Channel Adapters. The interactive mode uses a series of menus from which you select the option you want and enter the number for that option. For information about non-interactive mode operation—in which you simply enter a one- or two-letter code to perform operations on the adapter refer to Section...
8–Fibre Channel Interactive Commands Adapter Information Adapter Information 1. Adapter Information2. Fibre Channel Adapter From the main menu, select the Adapter Information option and then select 2 (Fibre Channel Adapter). The FC Adapter Information menu presents options to view Fibre Channel adapter information, Fibre Channel port information, Fibre Channel VPD information, and Fibre Channel target and LUN information.
8–Fibre Channel Interactive Commands FC Port Information (-i) -------------------------------------------------------------------------------- FC Port Information (-i) 1. Adapter Information2. Fibre Channel Adapter2. FC Port Information From the FC Adapter Information menu, select the FC Port Information option. From the port menu, select a port for which to view port information. For example: Adapter Information HBA Model QLE2462 SN: GFC0718P57753 1: Port...
8–Fibre Channel Interactive Commands FC VPD Information (-i) FC VPD Information (-i) 1. Adapter Information2. Fibre Channel Adapter3. FC VPD Information From the FC Adapter Information menu, select the FC VPD Information option. From the port menu, select a port for which to view VPD information. For example: Adapter Information HBA Model QLE2462 SN: GFC0718P57753 1: Port...
8–Fibre Channel Interactive Commands Adapter Configuration (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 Target List Menu ======================================================= : 0 Port: 1 : GFC0718P57753 HBA Model : QLE2462 HBA Desc. : QLE2462 PCI Express to 4Gb FC Dual Channel FW Version : 4.00.26...
8–Fibre Channel Interactive Commands HBA Parameters Boot Devices Configuration Target Link Speed (iiDMA) Export (Save) Configuration Generate Reports HBA Parameters 2. Adapter Configuration2. Fibre Channel Adapter1. HBA Parameters From the Fibre Channel Adapter Configuration menu, select the HBA Parameters option. From the port menu, select a port to open the HBA Parameters Menu with options to view adapter parameters, configure adapter parameters, and restore adapter defaults.
8–Fibre Channel Interactive Commands HBA Parameters Configure HBA Parameters (-n) 1. HBA Parameters<port selection>2. Configure HBA Parameters From the HBA Parameters Menu, select the Configure HBA Parameters option to open the Configure Parameters Menu with options to configure connection options, data rate, frame size, hard loop ID, loop reset delay, BIOS, Fibre Channel tape support, operation mode, interrupt delay timer, execution throttle, login retry count, port down retry count, LIP full login, link down timeout, target reset, LUNS per target, and receive out of order frame.
8–Fibre Channel Interactive Commands Target Persistent Bindings (-p) Restore Defaults 1. HBA Parameters<port selection>3. Restore Defaults From the HBA Parameters Menu, select the Restore Defaults option to reset the adapter parameters to their default values. For example: Warning: Please update the HBA parameters with extreme care. Incorrectly updating the HBA parameters may render the HBA inoperable.
8–Fibre Channel Interactive Commands Target Persistent Bindings (-p) Target ID : 2: Disk Vendor : SEAGATE Product ID : ST318453FC Port Name : 22-00-00-0C-50-68-1E-9A Port ID : 11-0A-E2 Bind : No Target ID 3: All Target(s) (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 Enter Target ID: 1 Target Persistent Binding - FC Port Configuration...
8–Fibre Channel Interactive Commands Boot Devices Configuration 2: Disk Vendor : SEAGATE Product ID : ST318453FC Port Name : 22-00-00-0C-50-68-1E-9A Port ID : 11-0A-E2 Bind : Yes Target ID 3: All Target(s) (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 Target Persistent Binding - FC Port Configuration Select More...
8–Fibre Channel Interactive Commands Boot Devices Configuration Configure Boot Device(s) (-e) 3. Boot Devices Configuration<port selection>2. Configure Boot Device(s) From the Boot Device Settings Menu, select the Configure Boot Device(s) option to open the Boot Device Settings submenu with options to configure the primary and alternate boot devices.
8–Fibre Channel Interactive Commands Target Link Speed (iiDMA) Basic Configuration 2. Adapter Configuration2. Fibre Channel Adapter4. Target Link Speed (iiDMA)1. Basic Configuration From the iiDMA Menu, select the Basic Configuration option to specify the link speed. For example: iiDMA Menu (Basic) ======================================================= : 0 Port: 1 : GFC0718P57753...
8–Fibre Channel Interactive Commands Export (Save) Configuration Apply Changes to selected Target(s) (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 iiDMA Menu (Advanced) ======================================================= : 0 Port: 1 : GFC0718P57753 HBA Model : QLE2462 HBA Desc.
2: WWPN: 21-01-00-1B-32-37-F9-C4 Loop Down (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 QLogic FCAPI v1.7.3 Build 38 Copyright (C) 2003-2010 QLogic Corp. All rights reserved. QLogic FC/FCoE Common Library Build Type: Release...
8–Fibre Channel Interactive Commands Adapter Updates Adapter Updates 3. Adapter Updates2. Fibre Channel Adapter From the main menu, select the Adapter Updates option and then select 2 (Fibre Channel Adapter). The Fibre Channel Adapter Update menu presents options options to update Flash memory, update adapter parameters, and update the parameter template.
8–Fibre Channel Interactive Commands Parameters Update (-r) Parameters Update (-r) 3. Adapter Updates2. Fibre Channel Adapter2. Parameters Update From the Fibre Channel Update menu, select the Parameters Update option. From the port menu, select a port for which to specify the parameter update file name.
8–Fibre Channel Interactive Commands Adapter Diagnostics (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 3 Updating HBA Parameters on HBA instance 0 - QLE2462. Please wait... HBA Parameters update complete. Changes have been saved to HBA instance 0 and are effective immediately.
8–Fibre Channel Interactive Commands Loopback Test (-kl) Loopback Test (-kl) 4. Adapter Diagnostics2. Fibre Channel Adapter1. Loopback Test From the FC Diagnostics menu, select the Loopback Test option. From the port menu, select a port to open the Loopback Test menu with options to view test parameters, reset test parameters, configure test parameters, and run the external loopback test.
8–Fibre Channel Interactive Commands Loopback Test (-kl) Display Test Parameters 4. Adapter Diagnostics2. Fibre Channel Adapter1. Loopback Test<port selection>1. Display Test Parameters From the Loopback Test menu, select the Display Test Parameters option to view the external loopback test parameters. For example: -------------------------------------------------------------------------------- HBA Instance 0: QLE2462 Port 1 WWPN 21-00-00-1B-32-17-F9-C4 PortID 00-00-00 --------------------------------------------------------------------------------...
8–Fibre Channel Interactive Commands Read Write Buffer Test Number Of Test(s) Test Increment(s) Abort On Error Start Diagnostics Test 4. Adapter Diagnostics2. Fibre Channel Adapter1. Loopback Test<port selection>4. Start Diagnostics Test From the Loopback Test menu, select the Start Diagnostics Test option to run the external loopback test.
8–Fibre Channel Interactive Commands Read Write Buffer Test Please Enter Selection: 1 Read Write Buffer Test Display Test Parameters Reset Test Parameters Configure Test Parameters Start Diagnostics Test Display Test Parameters (-kr) 2. Read Writer Buffer Test<port selection>1. Display Test Parameters From the Read Write Buffer Test menu, select the Display Test Parameters option to view the read write buffer test parameters.
8–Fibre Channel Interactive Commands Transceiver Diagnostics Monitoring Interface (DMI) HBA Desc. : QLE2462 PCI Express to 4Gb FC Dual Channel FW Version WWPN : 21-00-00-1B-32-17-F9-C4 WWNN : 20-00-00-1B-32-17-F9-C4 Link : Online ======================================================= Data Patterns Data Size Number Of Test(s) Test Increment(s) Abort On Error Enable/Disable Device(s) Start Diagnostics Test (-kr)
8–Fibre Channel Interactive Commands Transceiver Diagnostics Monitoring Interface (DMI) -------------------------------------------------------------------------------- Media Information -------------------------------------------------------------------------------- Vendor: FINISAR CORP. Type: 400-M6-SN-I Part Number: FTLF8524E2KNL Speed: 100 MBytes/Sec, 200 MBytes/Sec, 400 MBytes/Sec Revision: A Serial Number: PBA00CE -------------------------------------------------------------------------------- Temperature Voltage Tx Bias Tx Power Rx Power (mA) (mW)
8–Fibre Channel Interactive Commands Adapter Statistics Vendor PN: FTLF8524E2KNL Adapter Statistics 5. Adapter Statistics2. Fibre Channel Adapter From the main menu, select the Adapter Statistics option, and then select the adapter type (Fibre Channel Adapter). The FC Statistics menu presents options to view port statistics and link status.
8–Fibre Channel Interactive Commands Display FC Port Link Status Set Rate Set Log File Display HBA Statistics (-gs) 1. Display FC Port Statistics<port selection>4. Display HBA Statistics From the HBA Statistics Menu, select the Display HBA Statistics option to view Fibre Channel port statistics.
8–Fibre Channel Interactive Commands Display FC Port Link Status ======================================================= Display Parameters Reset Parameters Configure Parameters Display Link Statistics Display Parameters 2. Display FC Port Link Status<port selection>1. Display Parameters From the Link Statistics Menu, select the Display Parameters option to view link status logging parameters.
6. Refresh From the main menu, select the Refresh option to refresh (reload) the adapters and adapter port indexes. For example: Scanning for QLogic adapters, please wait... Using config file: C:\Program Files\...\iscli.cfg Using config file: C:\Program Files\...\netscli.cfg Loading: 1. CNA ... adapters, please wait...
8–Fibre Channel Interactive Commands Help (-h) network state, or firmware parameters. To ensure that you are viewing the most current information, you should perform a Refresh. (In some cases, QConvergeConsole CLI automatically refreshes the information before or after specific commands.) Help (-h) 7.
Converged Network Adapter Interactive Commands This section describes the interactive mode command line options for Converged Network Adapters. The interactive mode uses a series of menus from which you select the option you want and enter the number for that option. For information on noninteractive mode operation—in which you simply enter a one- or two-letter code to perform operations on the adapter, refer to the following sections for the corresponding adapter function:...
9–Converged Network Adapter Interactive Commands Adapter Information Adapter Information 1. Adapter Information1. Converged Network Adapter From the main menu, select the Adapter Information option, and then select the adapter type (Converged Network Adapter). The Converged Network Adapter Information menu presents options for viewing information about the adapter, ports, VPDs, VLANs, teaming, FCoE, iSCSI, and port target/LUNs.
Serial Number : AFE1028C03899 MAC Address Function 1 : 00:0e:1e:04:95:ec MAC Address Function 0 : 00:0e:1e:04:95:e8 Driver Information : QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Driver Name : qlxgnd64.sys Driver Version : 4.2.15.1125 Active Firmware Version : 4.07.31...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
1. Adapter Information1. Converged Network Adapter 3. CNA VPD Information<port selection>3. iSCSI From the CNA VPD Information menu, select the iSCSI option to view iSCSI port VPD information. For example: -------------------------------------------------------------------------------- Description : QLogic PCI-Express Dual Port 10Gb CNA Part Number : QLE8242 Serial Number : AFE1028C03899...
(p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 -------------------------------------------------------------------------------- Team: 1 Team Description: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 VLAN ID: None Team Type: Fail Over Team Members: CNA: 1 CNA Port: 1 MAC: 00:0e:1e:04:95:e8 Description: "QLogic Dual Port 10...
9–Converged Network Adapter Interactive Commands CNA FCoE Information (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 CNA FCoE Information FCoE 1. Adapter Information1. Converged Network Adapter6. CNA FCoE Information<port selection>1. NIC From the CNA FCoE Information menu, select the NIC option to view FCoE NIC port information.
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
9–Converged Network Adapter Interactive Commands CNA Port Target/LUN Information Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
9–Converged Network Adapter Interactive Commands Adapter Configuration (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 LUN List Menu HBA Instance 0 (QLE8242 Port 1) : Online Device Product Vendor: DGC Product ID : RAID 0 Product Rev...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online...
Page 206
9–Converged Network Adapter Interactive Commands CNA FCoE Configuration the value. Refer to Table 5-9 for details about these parameters and their values. For example: Connection Options Data Rate Frame Size Hard Loop ID Loop Reset Delay (seconds) Enable BIOS Enable HBA Hard Loop ID Enable Fibre Channel Tape Support Operation Mode Interrupt Delay Timer (100ms)
For example: Delete vPorts Menu HBA Instance 0 (QLE8242 Port 1) : Online WWPN: 21-00-00-0E-1E-04-95-EB Desc: QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) 1: vPort 0: WWPN: 21-DD-00-0E-1E-04-95-EB Online [ ] 2: Select All 3: Proceed (p or 0: Previous Menu;...
Page 216
9–Converged Network Adapter Interactive Commands CNA FCoE Configuration MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Driver Settings Menu -----------------------...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
Page 219
9–Converged Network Adapter Interactive Commands CNA FCoE Configuration Vendor : N/A Product ID : N/A Port Name : 20-70-00-C0-FF-D8-32-7F Port ID : 00-00-00 Bind : Yes Target ID (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 Selective LUN Menu (Configuration) Disk...
9–Converged Network Adapter Interactive Commands CNA FCoE Configuration HBA Instance 0 (QLE8242 Port 1) : Online Target WWPN 50-06-01-60-41-E0-63-25 LUN 0: Enable Disable (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 Select more LUN(s)? Select More Commit Changes...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
Page 226
Port Link Settings Menu ======================================================= : 0 Port: 2 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EE.5 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EE IPv4 Address : 192.168.1.45 ======================================================= Display Active Link Configuration Display Configured Link Configuration...
Page 227
4010 default port settings, and save changes. For example: Port Link Settings Menu ======================================================= : 0 Port: 1 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 ======================================================= Display Configured Port Settings...
Page 228
For example: Port Firmware Settings Menu ======================================================= : 0 Port: 1 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 ======================================================= Display Configured Port Settings Edit A Specific Port Setting...
Page 229
9–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Display Configured Port Settings—Select this option to view configured port settings. For example: ---------------------------------------------------------------------------- ---- *** Displaying ISCSI Settings inst=1 *** Force_Negotiate_Main_iSCSI_Keys iSCSI_Send_Markers off(*) iSCSI_Header_Digests iSCSI_Data_Digests iSCSI_Immediate_Data iSCSI_Initial_R2T iSCSI_Data_Seq_In_Order on(*) iSCSI_Data_PDU_In_Order on(*) iSCSI_CHAP_Auth off(*)
Page 230
9–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Configure Device Settings—Select this option to configure device settings. For more information about these settings, refer to Table 6-3. For example: Large_Frames [off] : ExeThrottle [0] : FirstBurstLen [256] : KeepAliveTO [30] : MaxBurstLen [512] : MaxOutstandingR2T [1] : IPv4TOS [0] :...
Page 232
Refresh—Select this option to refresh the adapter data. Legacy 4010 Restore Default Port Settings Select this option to restore QLogic 4010 iSCSI adapter default port settings. Save changes and reset HBA Select this option to save changes and reset the adapter.
Page 233
ID, save changes, and reset the adapter. For example: BIOS/UEFI Settings Menu ======================================================= : 0 Port: 1 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 ======================================================= Display BIOS/UEFI Information...
Page 234
9–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Target ID: 6 hba_no: 1 IP: 192.168.30.85 Port: 3260 TGT Instance #: 6 ISCSI Name: iqn.2010-03.com.apps4085:storage.disk4 Alias: State: Session Active Enter a Target ID:2 Enter a LUN Number[0,(default 0)]: Set Secondary Boot Target Information Select this option to set the secondary boot target parameters.
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
Page 240
CHAP entries, save changes, and refresh adapter data. For example: Configure Target Authentication Menu ======================================================= : 0 Port: 1 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 ======================================================= Display CHAP Table...
Page 241
9–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Display CHAP Table Select this option to view the CHAP table. For example: -------------------------------------------------------------------------------- CHAP TABLE Entry: 1 Name: chap_target1 Secret: q1w2e3r4t5y6 Entry: 2 Name: chap_target2 Secret: a1s2d3f4g5h6 Entry: 3 Name: chap_target3 Secret: z1x2c3v4b5n6 -------------------------------------------------------------------------------- Display Targets Using CHAP Entries Select this option to view targets that are...
Page 242
Edit a CHAP entry Select this option to edit a CHAP entry. Delete a CHAP entry Select this option to delete a CHAP entry. For example: CHAP TABLE Entry: 1 Name: qlogic Secret: qle82xx55 Entry: 2 Name: abcd Secret: 1234567890asdfghjk...
Page 243
9–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Mark Send Target for re-discovery Remove a Send Target Login and persist a discovered target Duplicate a Persistent Target Duplicate a Discovered Target Remove Discovered Target Display iSNS Settings Configure iSNS Save changes and reset HBA (if necessary) Refresh Display Send Targets Select this option to view the persistent send target list.
Page 244
9–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Add a Send Target Select this option to add a send target. For example: Do you want this new send target to be auto-login and persistent?y IPv6 Target? [off]: TGT_TargetIPAddress [0.0.0.0] :192.168.1.100 Does the send target require CHAP?y CHAP TABLE Entry: 1...
ID, save changes, and reset the adapter. For example: BIOS/UEFI Settings Menu ======================================================= : 0 Port: 1 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 SN0054667-00 B 9-59...
Page 246
9–Converged Network Adapter Interactive Commands CNA iSCSI Configuration iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 ======================================================= Display BIOS/UEFI Information Set BIOS/UEFI Mode Set Primary Boot Target Information Set Secondary Boot Target Information Clear Primary Boot Target Information Clear Secondary Boot Target Information Set Alternatve Client ID Save changes Save changes and reset HBA (if necessary)
Page 247
9–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Set Secondary Boot Target Information 2. CNA iSCSI Configuration5. Boot Devices Configuration<port selection>4. Set Secondary Boot Target Information From the BIOS/UEFI Settings Menu, select the Set Secondary Boot Target Information option to set the secondary boot target. For example: Target ID: 2 hba_no: 1 IP: 192.168.30.85...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
9–Converged Network Adapter Interactive Commands CNA NIC Configuration Refresh Save Host Configuration 6. Export (Save) Configuration<port selection>1. Save Host Configuration From the Export (Save) Configuration menu, select the Save Host Configuration option to save the host configuration. For example: What is the filename you would like to save this Host to? hostconfig Import HBA Configuration 6.
Port Settings Menu ======================================================= : 1 Port 1 : AFE1028C03899 CNA Model : QLE8242 CNA Desc. : QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter MPI Fw Version: 4.07.31 Physical MAC : 00-0E-1E-04-95-E8 LAA MAC : 00-0E-1E-04-95-E8 IPv4 Address : 192.168.10.55...
Page 251
9–Converged Network Adapter Interactive Commands CNA NIC Configuration Change MAC Alias Name Save Port Configuration Display Configured Port Settings 3. CNA NIC Configuration2. NIC Port Setting Configuration<port selection>1. Display Configured Port Settings Select the Display Configured Port Settings option to view configured port settings.
9–Converged Network Adapter Interactive Commands CNA NIC Configuration Refresh 3. CNA NIC Configuration3. VLAN Configuration6. Refresh From the Configure VLANs Menu, select the Refresh option to refresh the adapter information. For example: Refreshing CNA data ... Loading: 1. CNA ... Loading: 1.
Page 257
Subnet Mask : 255.255.0.0 IPv6 Address : fe80::a8af:6f72:3a1e:f781 Link Status : Up Primary Member : QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Updating parameters ... Plese wait ... Configurable Properties: ======================== IFP_Jumbo_Packet_Size : 1514 IFP_LSO_IPv4_V1 : Enabled...
Page 258
Select one or more CNA Port Indices (2 or ALL) : 2 Do you want ot set primary? (yes, no) [yes]: Member selected as Primary: QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Add Non-QLogic Ports as members? (yes, no) [no]: Updating parameters ...
Page 259
From the Configure Teams Menu, select the Configure Team Parameters option to configure team parameters. For example: Team Index: 1 Team Description: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 Select Team Index : 1 Updating parameters ... Plese wait ...
Page 260
1 Team Description: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 Select Team Index (or ALL) : 1 About to delete Team 1 Team Description: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3. Please wait Successfully deleted Team: 1, Team Description: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3.
Page 261
Team Members valiable for selection: 2. Description: QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Member selected as Primary: QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Saving team: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 About to save team config.
Page 262
Current selection: Team : [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 Primary : QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Clear primary? (yes, no) [yes]: y Saving team: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 About to save team config. Please wait ...
From the Save/Restore VLAN/Teams Menu, select the Restore VLAN & Teaming Configuration option to restore the VLAN and teaming configuration. For example: Enter file name (or ENTER for vtstate-user.cfg) : Accessing file: C:\Program Files\QLogic Corporation\QConvergeConsoleCLI\vtstate-user.cfg Number of Teams: 0 ----------------...
9–Converged Network Adapter Interactive Commands Adapter Updates Refreshing interfaces ... Please wait ... Updating IP properties for all ports ... Please wait ... Adapter Updates 3. Adapter Updates1. Converged Network Adapter From the main menu, select the Adapter Update option, and then select the adapter type (1: Converged Network Adapter).
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
Converged Network Adapter (CNA) Diagnostics CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] 9-80 SN0054667-00 B...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
9–Converged Network Adapter Interactive Commands Loopback Test Display Test Parameters 6. Loopback Test<port selection>2. FCoE1. Display Test Parameters From the Loopback Test menu, select the Display Test Parameters option to view the loopback test parameters. For example: -------------------------------------------------------------------------------- HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20 -------------------------------------------------------------------------------- -------------------- Diagnostics Settings...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
9–Converged Network Adapter Interactive Commands Read Write Buffer Test Display Test Parameters 7. Read Write Buffer Test<port selection>1. FCoE1. Display Test Parameters From the Read Write Buffer Test menu, select the Display Test Parameters option to view the read write buffer test parameters. For example: -------------------------------------------------------------------------------- HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20 --------------------------------------------------------------------------------...
9–Converged Network Adapter Interactive Commands Transceiver Diagnostics Monitoring Interface (DMI) WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 LED Test Starts ...
HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Media Information -------------------------------------------------------------------------------- Vendor: FINISAR CORP. Type: 10G Base-SR Part Number: FTLX8571D3BCL-QL Speed: 10 Gbits/Sec Revision: A Serial Number: AH208K5 QLogic SFP Installed: Yes -------------------------------------------------------------------------------- Temperature Voltage Tx Bias Tx Power Rx Power (mA) (mW) (mW) --------------...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
9–Converged Network Adapter Interactive Commands iSCSI Port Diagnostics Ping Target 11. iSCSI Port Diagnostics<port selection>1. Ping Target From the iSCSI Port Diagnostics menu, select Ping Target option to ping a target device. Specify the target IP address, the number of ping attempts, and the packet size.
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
9–Converged Network Adapter Interactive Commands iSCSI Port Logs Display ARP Table 12. iSCSI Port Logs<port selection>1. Display ARP Table From the iSCSI Port Logs menu, select the Display ARP Table option to view the ARP table. For example: ARP Table Entry number 0 ------------------------------- IPAddress = 192.168.1.11 MAC Address = 00-60-16-32-3E-7E...
9–Converged Network Adapter Interactive Commands iSCSI Port Logs Export Connection Error Log 12. iSCSI Port Logs<port selection>3. Export Connection Error Log From the iSCSI Port Logs menu, select the Export Connection Error Log option to export the connection error log to a file. For example: Enter the filename to save the connection error log to:log100 inst 0 Number of entries = 0x2 (2) inst 0 Number of displayed entries (for all target IDs) = 0x2 (2)
9–Converged Network Adapter Interactive Commands Adapter Statistics Adapter Statistics 5. Adapter Statistics1. Converged Network Adapter From the main menu, select the Adapter Statistics option, and then select the adapter type (Converged Network Adapter) to open the Converged Network Adapter (CNA) Statistics menu with options for viewing NIC port statistics, FCoE port statistics, FCoE port link status, and iSCSI port statistics.
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
CNA Model QLE8242 SN: AFE1028C03899 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online (p or 0: Previous Menu;...
CNA Model QLE8242 SN: AFE1028C03870 1. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:97:74 WWPN: 21-00-00-0E-1E-04-97-77 Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214. Link Down 2. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:97:70 WWPN: 21-00-00-0E-1E-04-97-73 Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214. Online (p or 0: Previous Menu;...
6. Refresh From the main menu, select the Refresh option to refresh (reload) the adapters and adapter port indices. For example: Scanning for QLogic adapters, please wait... Using config file: C:\Program Files\...\iscli.cfg Using config file: C:\Program Files\...\netscli.cfg Loading: 1. CNA ... adapters, please wait...
Ethernet Converged Network Adapter The most widely used LAN technology that QLogic Converged Network Adapters. transmits information between computer, support both data networking (TCP/IP) typically at speeds of 10 and 100 million and storage networking (Fibre Channel) bits per second (Mbps).
Page 296
User’s Guide QConvergeConsole CLI 2400, 2500, 3200, 8100, 8200 Series Adapters Fibre Channel path A high-speed serial interface technology A path to a device is a combination of a that supports other higher layer protocols adapter port instance and a target port as such as SCSI and IP.
Page 297
User’s Guide QConvergeConsole CLI 2400, 2500, 3200, 8100, 8200 Series Adapters port instance SCSI The number of the port in the system. Small computer system interface. A Each adapter may have one or multiple high-speed interface used to connect ports, identified with regard to the adapter devices, such as hard drives, CD drives, as port 0, port 1 and so forth.
Need help?
Do you have a question about the 2400 Series and is the answer not in the manual?
Questions and answers