KitchenAid KGHS02RWH1 Use & Care Manual page 12

Front-loading gas dryer
Table of Contents

Advertisement

Available languages

Available languages

1,
2.
Remove the red cap from the gas pipe.
Using a wrench to tighten, connect the gas supply to the
dryer. Use pipe-joint
compound on the threads of all non-
flared male fittings, If flexible metal tubing is used, be sure
there are no kinks.
A.............................
_
_
............................
B
A. Flared male fitting
B, Non-flared male fitting
NOTE: For LP gas connections,
you must use pipe-joint
compound
resistant to the action of LP gas. Do not use
TEFLON °t tape.
A combination
of pipe fittings must be used to connect the
dryer to the existing gas line. Shown is a recommended
connection. Your connection may be different, according to
the supply line type, size and location.
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Make sure that there are no kinks in the
flexible gas line.
4. Once the exhaust vent connection is made, remove the
corner posts and cardboard.
Check the levelness of the dryer. Check levelness first
side to side, then front to back.
3,
1
A. %" flexible gas connector
B. %" dryerpipe
C. %" to @" pipe elbow
D. %" pipe-to-flare
adapter fitting
Open the shutoff valve in the supply line. The valve is open
when the handle is parallel to the gas pipe.
If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again for
levelness.
..... ' _ _ s_
You can change your door swing from a right-side opening to a
left-side opening, if desired.
Remove
the door
1. Open the dryer door. Remove the 4 screws that hold the door
hinge on the front panel of the dryer. Loosen, but do not
remove, the screw with the top keyhole opening last (second
from the top).
4,
A. Closed valve
B. Open valve
Test all connections
by brushing on an approved
noncorrosive leak-detection
solution. Bubbles will show a
leak. Correct any leak found.
A, Dryer
B, De net remove.
C. Dryer door
Lift and pull forward on the door so that the keyhole clears
the screw head. Remove the door.
t®TEFLON
is a registered trademark
of E.I. Du Pont De Nemours and Company.
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kghs02rmt2Kghs02rmt1Kghs02rwh2

Table of Contents