PRO MODE

When the mode selection key is held down for four seconds in the RUN mode, the PRO mode will open.
The mode will change to the RUN mode when the mode selection key is held
down during this setting process. In this case, the changed item is entered.
The leftmost settings are the default settings (factory setting).
<RUN mode>
Hold down for
MODE
four seconds
<PRO mode>
When
'No.
display'
or
'Custom dis-
play' is set in
MODE
'Sub-display
selection'.
<Sub-display selection>
(Standard)
(Display OFF)
MODE
<Display speed selection>
250ms
(500ms)
MODE
<Hysteresis fixed value selection> (1 level: Approx. 1 digit) (When Pa unit is selected.)
MODE
<Displayed color relation selection>
Relating with com-
Relating with com-
parative output 1
parative output 2
MODE
<Eco mode setting>
OFF
(Standard)
MODE
<Setting check code>
Automatic
MODE
<Setting copy mode>
Copy sending
Copy sending
OFF
ON
MODE
<Reset setting>
MODE
<RUN mode>
Setting item
Changes the indication of the sub-display.
'
': Displays nothing.
'
' Presently selected pressure unit is displayed.
Sub-display selection
'
' Desired No. can be shown
'
' Desired numbers, alphabets (some of them cannot be displayed) and signs can be shown.
Display speed selection Changes the speed of the displayed pressure value on the main display.
Sets hysteresis of the EASY mode and the window comparator mode.
Hysteresis fixed
(8 steps)
value selection
Displayed color
The setting contents set at the displayed color setting in Menu setting mode
relation selection
can be related with either comparative output 1 or comparative output 2.
(Standard type only)
Current consumption can be lowered.
'
': Normal operation (ECO mode is off.)
'
' : If any key operation is not carried out for approx. 5 sec. in RUN mode,
the display becomes dark.
Eco mode setting
'
': If any key operation is not carried out for approx. 5 sec. in RUN mode,
the display is turned off.
Press any key to temporarily show the normal indication.
Current setting contents can be checked. For codes. refer to 'Code table'.
Setting check code
The setting of the master side sensor can be copied to the slave side sensors.
For details, refer to '
Copy mode setting
The setting contents are copied.
The setting contents are copied, and the slave side sensor goes into key-lock state.
Reset setting
Returns to default settings (factory settings).
<Sub-display selection>
When '
' is set.
When '
' is set.
MODE
MODE
Change the dis-
played details with
and
.
MODE
MODE
<RUN mode>
(Unit display)
(No. display)
(1,000ms)
(Max.)
(Min.)
(Max.)
Copy sending
ON-L
MODE
MODE
Description
11

SETTING COPY FUNCTION

Code table
First digit
Comparative out-
put 1 output mode
EASY
Hysteresis
MODE
Window
comparator
MODE
(Custom display)
Fifth digit
Response time
100ms
250ms
500ms
1,000ms
5,000ms
11
SETTING COPY FUNCTION
This can copy the settings of the master side sensor to the slave side sensor.
Be sure to use the setting copy function between the identical models.
This function cannot be used between different models.
Only one sensor can be connected on slave side with a master side sensor for the setting copy function.
<Setting procedure>
Set the setting copy function of the master side sensor to 'Copy sending ON' or
'Copy sending ON-L', and then press the mode selection key so that the sensor is in
copy ready state. For details, refer to <Setting copy mode> in '
Turn off the master side sensor.
Connect the master side sensor with the slave side sensor as shown below.
Color code of cable with connector
Master side sensor
Copy ready
Notes: 1) For the high-function type, analog voltage / external input.
state
Turn on the master side sensor and the slave side sensor at the same
time. (Note 2) (Note 3)
Set contents (16-bit coded) are shown in orange on the main display of
the master side sensor and the copying starts.
The same code explained above is shown in green on the the main display of the
slave side sensor, and '
Turn off the power of the master side sensor and the slave side sensor
and disconnect the wire.
If copying the setting to another sensor repeatedly, follow steps
Notes: 2)
Take care that if the power is not turned on at the same time, the setting con-
tents may not be copied.
3)
Note that when the power is on, pulse output is output to comparative output 1.
<To cancel the setting copy mode of master side sensor>
Whilst the slave side sensor is disconnected, turn on the power of the
master side sensor.
Press the mode selection key for approx. two seconds.
Second digit
High-func-
Standard type
tion
Comparative out-
N.O. / N.C.
N.O. / N.C.
Analog voltage out-
put 2 output mode
selection
put / external input
selection
Analog volt-
N.O.
OFF
OFF
age output
Auto ref-
N.C.
N.O.
erence
EASY
Remote zero-
N.O.
N.C.
adjustment
N.C.
N.O.
Hysteresis
N.C.
N.O.
N.C.
N.O.
Window
comparator
N.C.
6th digit
Unit selection
2.5ms
MPa
5ms
kPa
2
10ms
kgf/cm
25ms
bar
50ms
psi
mmHg
inchHg
(Brown) +V
(Blue) 0V
(Black) Comparative output 1
(Black) Comparative output 1
(White) Comparative output 2 (Note 1)
(White) Comparative output 2 (Note 1)
' is shown on the sub-display (When copying is complete.)
Fourth digit
Third
Standard
digit
type
type only
Displayed color of
Displayed
Threshold
display
the main display
color relation
C o m p a r a-
P-1, Lo-1
tive output 1
Red when
ON
C o m p a r a-
Hi-1
tive output 2
C o m p a r a-
P-2, Lo-2
Green when
tive output 1
ON
C o m p a r a-
Hi-2
tive output 2
C o m p a r a-
ADJ.
tive output 1
Always red
C o m p a r a-
tive output 2
C o m p a r a-
tive output 1
Always green
C o m p a r a-
tive output 2
7th digit
8th digit
Display speed
Eco mode
250ms
OFF
500ms
Std
1,000ms
Full
10
PRO MODE'.
Power supply
Slave side sensor
(Brown) +V
(Blue) 0V