UPPER
SHELL
REMOVAL
NOTE:
Upper
shell
removal
is necessary
when
access to
internal
parts of the heater
is necessary.
1. Remove
the six
(6) screws from
the upper
shell flanges
which
run along each side of the heater.
2. Grip
the upper
shell flange
along
one side of the heater,
pull away
from
the heater to disengage
it from
the lower
shell
flange,
and
lift
up.
Disengage
the
opposite-side
flanges
and lift
off the upper
shell.
3. Replace
the upper
shell by engaging the upper and lower
shells'
flanges
on one side of the
heater,
then
pull
out
and press down
the upper
shell
flange,
on the opposite
side, to engage the lower
shell flange.
4. Align
the six (6) screw holes and install
the screws.
Upper
Shell
Lower Shell
/zScrew
(6)
ELECTRICAL
1. Remove the upper shell, as described in this manual,
and lift off the top fan shroud.
2. Check all internal wiring, for deterioration (hardness and
cracking), obvious component damage, and loose connec-
tions. Repair or replace as necessary.
NOTE:
When
in doubt
about
your
ability
to repair
your
heater,
take it to your
Sears Service
Center.
EU
S T
SAFETY
E T
CONTROL
WHITE
POWER
6OI20PLUG
HZ
V
GREb_
EN
WHITE
WHITE
BLUE
PHOTO -
CELL
WHITE
SPARK
PLUG
RED
RED
Spark Plug
Always make sure the heater is unplugged before
attempting removal of spark plug.
NOTE: At the beginning of each heating season, and after
every 300 hours of operation,
the spark plug must
be removed, cleaned, and gapped. If plug's electrodes
are burned or eroded, replace the plug.
3. Pull the spark plug wire terminal
up and off of plug.
4. Remove
two
(2) screws and the nozzle
adapter
bracket
which
mounts
the spark
plug and nozzle
adapter.
5. Remove the lock nut retaining
the spark plug in the
bracket and remove the plug from the bracket.
6. Clean and gap the plug's electrodes
to 0.050/.060",
or
replace the plug if necessary, making sure the new plug is
properly gapped.
7. Insert the plug into the bracket and thread the Iocknut onto
the plug. Before tightening the nut, position the plug so the
gap between the electrodes is positioned
as illustrated.
Tighten the nut.
8. Position
the
nozzle
adapter
bracket
so screw holes
align. Insert and tighten both screws.
9. Push the spark plug wire terminal
onto
plug.
10.
Set
the
top
fan
shroud
in
position
and
install
the
upper shell.
FRONT VIEW
ROTATE
SPARK PLUG
TO POSITION ELEC-
PLUG
ADAPTER
NOZZLE ADAPTER BRACKET
TOP VIEW
MOTOR
The motor
is a sealed unit and cannot be lubricated
or
serviced electrically.

Advertisement