iNSTALL
THE DUCTWORK
(DUCTED HOODS ONL Y)
,_
CAUTION: To reduce the risk of fire, use only metal ductwork.
1. Decide where the ductwork will run between the hood and the outside.
2. A straight, short duct run will allow the hood to perform most efficiently.
3. Long duct runs, elbows, and transitions
wilt reduce the performance
of the
hood. Use as few of them as possible. Larger duct!rig may be required for best
performance with longer duct runs.
4. Install a roof or wall cap. Connect round metal ductwork to cap and work back
towards hood location. Use duct tape to seal the joints between ductwork sec-
tions.
[
ROOF CAP
\
]
iNSTALL
ELECTRICAL
_, WARNING: Electrical wiring must be done by a qualified person(s) in accor-
dance with all applicable
codes and standards.
This range hood must be
properly grounded.
Turn off electrical power at service entrance before wiring.
(DUCTED AND NON-DUCTED
HOODS)
1. Plan where the hood will be located above the cook top.
2. Run electrical cable, 2-wire plus ground, to the hood location as shown.
3. Flues conceal the cabte. Make sure cable exits the wall within dimensions shown
and long enough to reach the hood. Fig. 5.
iNSTALL
MOUNTING
BRACKET
(DUCTED AND NON-DUCTED
HOODS)
1. Construct wood wall framing
that is flush with interior surface of wall studs.
Make sure:
a) the framing is centered over installation location.
b) the height of the framing will allow the mounting
bracket to be secured to
the framing within the dimensions
shown.
2. After wall surface is finished
secure mounting bracket to framing using dimen-
sions shown.
CEILING
HEIGHT
&'FOOT
&'FOOT
&'FOOT
1&.FOOT
(see note b}
DUCT
METHOD
DUCTED
NON-DUCTED
DUCTED OR
NON-DUCTED
DUCTED
HOOD DISTANCE ABOVE 36_' HIGH COOK TOP (see note a)
_"
! 2s" !
_"
!
z_"
!
28" !
29" ! 30"
MOUNTING
BRACKET
LOCATION
ABOVE
36" HIGH COOK
TOP
40 _'
41"
42"
4d'
44"
39"
39"
39"
39"
4d _
41 '_
4Z _
4U _
41 '_
42 '_
4_ _
44 '_
4,5 ,_
4d _
41 '_
4Z'
4,3"
44 '_
45"
FRAMING BEHIND WOOD CROSS
/
DRYWALL
WOOD
CROSS
SUPPORT
Note a - Minimum hood distance above cook top must Rot be less than 24".
A maximum 30" above cook top is highly recommended for best capture of cooking
impurities.
Distances over 30" are at the installers discretion; and if ceiling height and flue length
permit.
Note b - a 10-foot high ceiling requires use of an optional flue extension FXWC50EC,
available from your local dealer.