COMMON QUESTIONS AND ANSWERS
Q_
Am
a_
A,
a_
A_
Q.
Ao
Q,
Ao
a_
A_
Why isn't my Electronic Air Cleaner cleaning
my air?
The air cleaner is most likely working
just like it was designed, However, many
factors can affect the performance
of the unit_ Are air return registers located in
the ceiling? If so, it will be difficult
for the air flow to carry heavier particulates
to
the air cleaner. If the dirt does not get to the air cleaner, it cannot be removed
from the air. Are both the Red and Green indicating
lights illuminated?
If not, the
unit may be in need of servicing.
It still isn't cleaning my air the way 1want it to, What can 1do?
It is recommended
that you operate the HVAC system continuously
so that the air
movement
will
carry the
dirt
to the
air cleaner
where
it can be collected.
Unfortunately,
there will always be some dirt that is left behind on the appliances,
furniture,
etc. Regular dusting is recommended
to stir up these pockets of dust so
that they can enter the air stream and be removed by the Electronic Air Cleaner.
When
t turn
on my Electronic
Air Cleaner, the lights come on for a couple of
seconds and then turn off. The air cleaner isn't working!
The air cleaner is operating
properly as long as both the Red and Green indicating
lights are illuminated.
Try turning
the HVAC blower
ON and then turning
the
Electronic Air Cleaner ON_ This should solve the problem
What is the zapping
noise I am hearing from my unit? Should I be concerned?
The zapping or popping
noise that you are hearing is the sound of larger particles
being "vaporized"
by the Ionizing-Collecting
Cel!o This is normal and is no cause
for alarm_ As your HVAC system blower
moves the air through
the ductwork
and
allows the Electronic Air Cleaner to clean the air, the noise will diminish, However,
there will always be instances when larger particles enter the Ionizing-Collecting
Cell, and are "vaporized",
Should 1 hear this zapping noise all the time?
All Electronic
Air Cleaners will occasionally
zap or pop as larger particles
pass
through
the lonizing_Colfecting
Ceils° However,
if the sound
is constant
or is
repetitive
in nature, then a large particle may have become lodged in the lonizing_
Collecting
cell and may require
removal
by cleaning,
If cleaning
the Ionizing-
Collecting
Cell does not stop the noise and/or there are no large particles trapped
in the ionizing-Collecting
Cell, then the cause could be a broken/loose
ionizing
wire, bent collector
plate or other mechanical fault.
What if I no longer hear any popping
or zapping noises coming from my unit? Is
it still cleaning the air?
tf the zapping
noises stop and the air cleaner is not in need of servicing, then one
of two situations
has occurred_ First, the Electronic Air Cleaner has successfully
removed
all larger particles
from
the air and is cleaning
microscopic
particles
which do not cause the zapping
noises° Second, the HVAC system blower
is not
operating
and air is not flowing
through
the ductwork_ The Electronic Air Cleaner
cannot remove particles if the air stream is not moving.