Fault Diagnostics

Fault
No power
Unit functions ok but no audio
Volume control locks up
DC offset
Unit fails to respond to commands
Unit gets very hot
Hints & Tips
!
To check software version press PHONO, TUNER, DVD buttons on the front panel
simultaneously.
!
On issue 2 phono boards only, fit Kapton insulation tape to the phono stage PCB (rear panel
end) to prevent track shorting to chassis.
!
Check all fuses are the correct rating.
!
Check DC offset alterations are fitted as per ECO 01_1101
!
To isolate a fault between the pre or power amp section press the PRE/PWR button on the
rear panel to separate the two sections.
!
Check R100 on amp/psu board is not shorting to the track underneath (through plated via).
Action
Check fuses
Check power supply rails
Check preamp fuses
Check RL100A (volume control mute relay)
Check +5V supply rail
Check mute signal line
Check software version is 2.0 or higher
Check equipment connected to amp for DC on the audio leads
Check alterations as per ECO 01_1101 have been fitted
Check ribbon cable from display to main board
Check ribbon cable from display to preamp board
Check power stage IQ settings